- 12 -
12. Center the plenum over the hood.
Fig. 19.
13. Attach plenum to the ceiling using
(2) drywall anchors and (2) 4.8 x 38
mm screws, as shown.
14. Press duct connector into the
plenum until it snaps into place. Fig.
20.
15. Attach 5-inch dia. expandable
ducting to the plenum and tape joint
with aluminum duct tape.
16. Stretch expandable duct, attach it to
the 5”-to-6” adapter and tape duct
joints. Fig. 21.
17. Plug power cord into wall outlet.
18. Position upper and lower flues onto
the hood.
19. Align tabs on bottom edge of lower
flue with slots on top of the range
hood.
20. Make sure recirculation slots on the
upper flue are exposed, as shown.
21. Lift upper flue up until mounting
holes align with holes in the plenum.
22. Install (2) 3.9 x 9.5 mm mounting
screws to secure upper flue to
plenum.
FIG.20
FIG.19
FIG.21
5-7/8”
1-3/8”
3/8”
4.8 x 38mm
SCREWS
PLENUM
PLENUM
DUCT
CONNECTOR
3.9 x 6mm
SCREWS
5” DIA.
EXPANDABLE
DUCT
NON-DUCTED INSTALLATION
WITHOUT FLUE AND
BLADE GUARD ONLY
10. Install blade guard. Align tabs of the
guard with slots on top of the hood.
Fig.22
11. From inside the hood , bend tabs
over to secure the blade guard to the
hood.
12. Plug power cord into 120 VAC
receptacle . Fig.23
13. Coil and tape remaining power cord
to the top of the range hood.
FIG.2
2
TABS
FIG.2
3
TAPE
Summary of Contents for WM34I