background image

ALCOVE

ONLY

BigE Walk-In Tub    USA/CANADA 2010           Page 12 of 14

PREPARING

THE AREA

PREPARE THE DRAIN.

MIN. 5" x 5" HOLE FOR

DRAIN PIPE

PREPARE THE HOT AND

COLD WATER SUPPLY

FINAL DRAIN-

AND HOT/COLD

CONNECTION

MAGNET

CHECK THAT 

THE TUB IS LEVEL

FINAL

INSTALLATION

LEVEL THE FLOOR TO ENSURE THAT
ALL FIVE LEVELING FEET WILL TOUCH

PREPARING

THE TUB

Installation schematic for BigE walk-in tub

for ALCOVE installation (with add-on flanges)

INSTALL THE VALVE ROUGH-IN
(UNLESS FACTORY INSTALLED)

15"

ATTACH THE FLANGES BY FIRST LAYING A BEAD OF SILICONE ON THE
FLANGE OR ON THE TUB WHERE THE FLANGE WILL GO. NEXT,  SCREW
THE NAILING FLANGES TO TUB. PLACE THE FOIL TAPE ON THE OUTSIDE
CORNER TO CONTINUE THE BACK NAILING FLANGE AND LAY ONE FINAL

BEAD OF SILICONE TO JOINT OF THE TUB AND NAILING FLANGE.

ACCESS PANELS MAY BE REMOVED TO PREVENT DAMAGE AND MAKE HANDLING DURING INSTALLATION MORE CONVENIENT.

MAKE SURE TO KEEP THEM IN A SAFE PLACE TO AVOID DAMAGE, AS THEY WILL NEED TO BE REATTACHED AFTER FINAL INSTALLATION.

1

ATTACH THE CABLE/LANYARD

TO MAGNET SCREW AND NUT

TO MEET CODE 

4

FOIL TAPE

SCREW BACK NAILING
FLANGE TO THE STUDS

2

10"

10"

3

1

4

3

2

1

3

2

INSTALL THE

WASTE/OVERFLOW

AND DOOR DRAIN

FITTING

USA - 120V/15A GFCI
    OUTLETS REQUIRED IN
    THIS AREA
CANADA - 120V/15A GFCI
    OUTLET OR JUNCTION
    BOX IN THIS AREA PER
    CSA CODE C22.2 No. 218.2

14"

18"

Summary of Contents for BigE XTWJ6035

Page 1: ... be provided to the Best Bath Systems Walk In Tub owner user FOR INDOOR USE ONLY UTILISER A L INTERIEUR SEULEMENT The BigE model XTWJ6035 Walk In Tub Installation and Operating Instructions IMPORTANT INSTALLATION and OPERATING INSTRUCTIONS BigE Walk In Tub USA CANADA 2010 Page 1 of 14 ...

Page 2: ...ERTHERMIA PEOPLE USING MEDICATIONS AND OR HAVING AN ADVERSE MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH HEATER NOTE NEVER DROP OR INSERT ANY OBJECT INTO ANY OPENING DO NOT OPERATE THIS UNIT WITHOUT THE GUARD OVER THE SUCTION FITTING AVERTISSEMENT RISQUE DE BLESSURE ET DE NOYADE NE PAS LAISSER UN ENFANT UTILISER LA CUVE A REMOUS EN L ABSENCE D UN ADU...

Page 3: ...ectrical wiring service and repair in accordance with all applicable local and national codes Failure to do so may pose an electrical hazard 7 Before making any electrical connections make certain that the electrical power is turned OFF at the breaker and take measures to ensure that it CANNOT accidentally be turned on again 8 Building materials and wiring should be routed away from the blower or ...

Page 4: ...th a pump and a blower a 30Amp 125Volt properly grounded and circuit breaker protected line must be hard wired into the factory installed junction box CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER CONNECT ONLY TO A BRANCH CIRCUIT PROTECTED BY AN OVERCURRENT PROTECTION DEVICE RATED NOT MORE THAN 30 A BRANCHER SEULEMENT À UNE DÉRIVATION PROTÉGÉE PAR UN DISJONCTEUR...

Page 5: ...cumstances use wire brushes metal sponges knives steel wool or scouring pads on any part of the tub 2 Do not under any circumstances use powerful solvent such as acetone lacquer paint thinner benzene or abrasive cleanser on any part of the tub 3 Do not use ammonia or chlorine based agents on any plated surface as they will deplate the surface and void the warranty on the plated finish For a one ti...

Page 6: ... temperature for your use of the tub The symptoms of hyperthermia include in the internal temperature of the body dizziness lethargy drowsiness and fainting The effects of hyperthermia are as follows 1 Failure to perceive heat 2 Failure to recognize the need to exit the hydro massage 3 Unawareness of impending hazard 4 Fetal damage in pregnant women 5 Physical inability to exit the Walk In tub 6 U...

Page 7: ...n valve handle the cover of the overflow all the way to the left counter clock wise to close the drain 5 Fill to the water level that is comfortable for you but at least one inch above the highest water jet 6 Read and follow the information regarding hyperthermia However under no circumstances use a bathtub with water above 40 C 104 F 7 To operate the water jets press the on buttons on the key pad...

Page 8: ...is in the locked position forward If the latch is not secure when draining the tub as the water level lowers the pressure on the door will be reduced thus increasing the possibility of a leak around the door 3 It is especially IMPORTANT to wipe down the door seal and door jamb after each use in order to maintain the integrity of the seal NOTE If there are any contaminates i e dirt dust sand etc or...

Page 9: ...heir allotted time and to Best Bath Systems Customer Service within five 5 business days of delivery Abusive treatment misuse normal wear and tear accidents fire repairs or alterations not authorized in writing by Best Bath Systems theft lost materials improper installation damage to product due to shipping storage or handling reactions caused by accessories or cleaning materials mis drilled holes...

Page 10: ...case where a portion of this warranty is found to be not legal or conflicting with any state law that portion of this warranty is voided but all other portions remain valid Modifications to this Warranty This document supersedes all previous warranties written verbal or implied issued by Best Bath Systems Inc Best Bath Systems Inc reserves the right to modify or change this warranty in its entiret...

Page 11: ...SA CANADA 2010 Page 11 of 14 FLOW TUB DRAIN DOOR DRAIN Door Drain Venturi Instructions Door Latch Adjustment Set screw 1 8 Allen wrench To adjust pressure of door on door seal Loosen set screw with 1 8 Allen wrench Rotate lever as required for more or less pressure Tighten set screw CHECK VALVE ...

Page 12: ...HE FLANGE OR ON THE TUB WHERE THE FLANGE WILL GO NEXT SCREW THE NAILING FLANGES TO TUB PLACE THE FOIL TAPE ON THE OUTSIDE CORNERTOCONTINUETHEBACKNAILINGFLANGEANDLAYONEFINAL BEAD OF SILICONE TO JOINT OF THE TUB AND NAILING FLANGE ACCESSPANELSMAYBEREMOVEDTOPREVENTDAMAGEANDMAKEHANDLINGDURINGINSTALLATIONMORECONVENIENT MAKESURETOKEEPTHEMINASAFEPLACETOAVOIDDAMAGE ASTHEYWILLNEEDTOBEREATTACHEDAFTERFINALIN...

Page 13: ...REW THE NAILING FLANGE TO TUB PLACE THE FOIL TAPE ON THE OUTSIDE CORNERTOCONTINUETHEBACKNAILINGFLANGEANDLAYONEFINAL BEAD OF SILICONE TO THE JOINT OF THE TUB AND NAILING FLANGE ACCESSPANELSMAYBEREMOVEDTOPREVENTDAMAGEANDMAKEHANDLINGDURINGINSTALLATIONMORECONVENIENT MAKESURETOKEEPTHEMINASAFEPLACETOAVOIDDAMAGE ASTHEYWILLNEEDTOBEREATTACHEDAFTERFINALINSTALLATION 1 2 3 1 2 3 4 1 3 ATTACH THE CABLE LANYARD...

Page 14: ...REVENTDAMAGEANDMAKEHANDLINGDURINGINSTALLATIONMORECONVENIENT MAKESURETOKEEPTHEMINASAFEPLACETOAVOIDDAMAGE ASTHEYWILLNEEDTOBEREATTACHEDAFTERFINALINSTALLATION 1 2 2 1 3 ATTACH THE CABLE LANYARD TO MAGNET SCREW AND NUT TO MEET CODE 4 SCREW BACK NAILING FLANGE TO THE STUDS 2 6 PREPARE THE HOT AND COLD WATER SUPPLY LEVEL THE FLOOR TO ENSURE THAT ALL FIVE LEVELING FEET WILL TOUCH 1 3 4 42 12 PREPARING THE...

Reviews: