33
The following items are available only when Fan Control Mode is set to [Smart Fan IV Mode].
Temperature 1~4
Determines the temperature value for the Smart Fan
IV mode. Input value range: [0~255]
Fan PWM 1~4
Determines the amount of Fan PWM value for the
Smart Fan IV mode Input value range: [0~255]
Tolerance of Temperature [0]
Input value range: [0~7]
Critical Temperature [75]
Input value range: [0~255]
Critical Temp Tolerance [0]
Input value range: [0~7]
Fan Count Step Up [5]
Input value range: [0~15]
Fan Count Step Down [5]
Input value range: [0~15]
Fan Out Step Up Time [10]
Determines the amount of time Fan Out takes to
increase its value by one step. Input value range:
[0~255]
Fan Out Step Down Time [10]
Determines the amount of time Fan Out takes to
decrease its value by one step in intervals of 0.1
seconds. Input value range: [0~255]