background image

 

 

18 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

Chapter 3 

Operation 

Summary of Contents for NSP-20H1

Page 1: ...1 Network Security System NSP 20H1 Always at the forefront of innovation User Manual...

Page 2: ...t 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses...

Page 3: ...electrical discharge can damage computer components without causing any signs of physical damage You must take extra care in handling them to ensure against electrostatic build up 1 To prevent electr...

Page 4: ...pe recommend by the manufacturer Dispose of used batteries according to local ordinance Before using the system prepare basic system components If the system comes as a barebone that is none of the ke...

Page 5: ...2 3 Open Up Top Cover 14 2 4 Accessing Processor Memory 15 2 5 Adding 2 5 3 5 SATA Hard Drive 15 2 6 Accessing CompactFlash Card 17 Chapter 3 Operation 3 1 Turning On The System 19 3 2 Accessing Micr...

Page 6: ...6 Chapter 1 General Information...

Page 7: ...e of pre defined codes and are under visual monitoring via the LED indications at front panel Yet further access to full status is also available via software programming One PCIe X8 expansion slot is...

Page 8: ...EDs LAN 6x RJ45 1G LAN Ports Console 1x Micro USB Console 1x RJ45 Type Console Port USB 2x USB 3 0 Ports Switch 1x Push Button Power Switch Rear I O Power Inlet 1x Standard Power Cord Inlet Internal I...

Page 9: ...ur RJ45 1G Bypass 2 Pairs BEM H110 580 C8 Type LAN Module Chipset Dual Intel 82580EB Interface PCIe 3 0 X8 with Switch Network Port Eight RJ45 1G BEM H110 350 F4 Type LAN Module Chipset Intel i350 AM4...

Page 10: ...10 Figure 1 1 System Layout of NSP 20H1 1 4 System Layout...

Page 11: ...11 Front View With 4 Port SFP GbE LAN Module Rear View 1 5 Indicators Features...

Page 12: ...12 Chapter 2 Preparation...

Page 13: ...s Humid environment tends to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Computer components and electronic circuit b...

Page 14: ...icated in the places below prior to any moving of the top cover It is recommended to push the top cover backwards so as to detach the cover tongue out of the snatch up at front side before the lift up...

Page 15: ...e Hard Drive bracket red circles as below Remove these screws to acquire the Hard Drive bracket 3 This Hard Drive bracket is designed to hold two 3 5 SATA Drives with also two smaller L bracket for tw...

Page 16: ...ller L brackets leaving the Hard Drive I O at either end as the brackets are symmentrically designed and add the eight screws enclosed in the accessory screw bag for a perfect and firm Hard Drive subs...

Page 17: ...ard as the red circle Please be advised that CompactFlash card on IDE interface is never to be added or removed when the system power is still turned on that is no plug and play scheme is enabled for...

Page 18: ...18 Chapter 3 Operation...

Page 19: ...USB cable is just perfect to connect this port with the standard USB port of your terminal PC This is particularly useful for those notebook PCs where COM port is no longer available and usually a US...

Page 20: ...ress once on the power switch as located below with yellow arrow or press and hold for 4 seconds to reach that goal If such a power scheme is not wished please consult our technical support to disable...

Page 21: ...Micro USB cable to this port and connect the other end to the USB port of PC or laptop Please be advised that you need to load Microsoft Windows 7 or above on this PC or laptop to go ahead with the pr...

Page 22: ...3 Press del to go to BIOS setup menu 4 Choose to confirm SATA Controller status If it is enabled select a SATA mode and go to 6 5 If SATA Controller is disabled bring it up and reboot to allow a re d...

Page 23: ...r Bypass mode or Green for PassThrough mode Such Bypass LEDs would lit the same way for both Power On and Power Off mode setting as long as power cord is plugged at power supply inlet that leads to a...

Page 24: ...on going 3 Off Network is not connected LAN Speed LED The right LED is LAN Port Speed LED with three different speeds 1 Amber 1000 Speed 2 Green 100 Speed 3 Off 10 Speed Summary Table LED Color State...

Page 25: ...25 Chapter 4 BIOS Setup...

Page 26: ...executed under the following conditions When changing the system configurations When a configuration error is detected by the system and you are prompted to make changes to the Setup program When res...

Page 27: ...followingmessageduringthe POST TO ENTER SETUP BEFORE BOOT PRESS CTRL ALT ESC OR DEL KEY Pressthe Del keyor pressthe Ctrl Alt and Esc keysto enterSetup The online description of the highlighted setup...

Page 28: ...system configuration Advanced Advanced system settings Chipset Other functions Security Configure Supervisor and User Password Boot System boot configuration Save Exit Exit options as well as loading...

Page 29: ...onfiguration H W Monitor Serial Port Console Redirection and CSM Configuration Super IO Configuration Serial Port 1 2 Configuration Serial Port This setting enables disables the specified serial port...

Page 30: ...ntrol Mode Configure Fan Speed Control Mode Serial Port Console Redirection Console Redirection Enables or disables Console Redirection function CSM Configuration Boot option filter This controls Lega...

Page 31: ...31 CPU Configuration Display CPU Information 4 6 The Chipset Menu...

Page 32: ...32 System Agent SA Configuration PEG Port Configuration PEG Port Options Memory Configuration Display memory size Frequency SATA Configuration SATA Controller s Enable or disable SATA Device...

Page 33: ...33 Administrator Password Set Administrator Password User Password Set User Password 4 7 The Security Menu...

Page 34: ...wait for setup activation key 65535 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option FIXED BOOT ORDER Priorities...

Page 35: ...nd Reset Reset system setup without saving any changes Restore Defaults Restore Load Default values for all the setup options Launch EFI Shell from filesystem device Attempts to Launch EFI Shell appli...

Page 36: ...36 Chapter 5 Software Configuration...

Page 37: ...c driver 2 Make the file with this command make or make clean then make again if error message prompts 3 Install driver files with this command insmod caswell bpgen3 ko 4 Now two file folders g3bp0 an...

Page 38: ...Bypass LED is green and the network connection is not available Now go to the folder g3bp0 and issue this command echo b bypass This will change the status of Bypass pair 1 to bypass mode also the bo...

Page 39: ...p Bypass LED is green and the network connection is not available Now go to the folder g3bp1 and issue this command echo b bypass This will change the status of Bypass pair 2 to bypass mode also the t...

Page 40: ...r g3bp1 and issue this command echo 1 nextboot Reboot to see this change take effect Both Bypass LEDs are turned to red and as in the picture below the notebook is now connected to internet To reverse...

Page 41: ...right to complete the job Please logon to root now Install the driver files 1 Open up the driver file folder as Your File System src driver 2 Make the file with this command make or make clean then m...

Page 42: ...as GPO pins with value low The pin 1 3 5 7 are defined as GPI pins A few jumpers will be added onto pin 1 2 3 4 5 6 7 8 so pin 1 will read the value of pin 2 pin 3 will read the value of pin 4 etc Wi...

Page 43: ...43 Now move these two jumpers onto 3 4 and 7 8 Pin 3 and pin 7 will now read value low Users are welcome to configure this GPI script for other programming jobs...

Page 44: ...ns Pin 2 4 6 and 8 are negative pins The script will change the value of Pin 1 3 5 and 7 so when the a high is set LED will be turned on If a low is set LED will be turned off Walkthrough 1 LED on Pin...

Page 45: ...45 Chapter 6 Q A...

Page 46: ...1 CMOS checksum error due to Clear CMOSapproach Press F1 to bringupBIOSsetupmenuandloadoptimal setting 2 Bad Hard Drive Remove SATA signal cable or CompactFlash card and boot again 3 Bad external dev...

Page 47: ...etween RJ45 port and network chip Q Can I enable Bypass function at Power Off mode A Yes you certainly can NSP 20H1 comes with dual latch relay that will work at both power on and power off mode Q Can...