background image

8

Bleeding The Air Purge Valve

NOTE:

 Water must be at the printed level on the spa wall.

NOTE:

 Bleeding the air purge valve is the key step to ensure the pump runs normally.

CAUTION:

 You must ensure the pump is prepared before operating, if you do not follow these 

instructions the pump may operate abnormally. Never dry run the pump as this type of damage 
is not covered by the warranty.
1. Open the air purge valve located on the top of the pump by turning the knob counter clockwise. 
    Maximum ventilation occurs with two full turns of air purge valve.

NOTE:

 If the valve becomes unthreaded, simply place it back on and turn clockwise to rethread.

2. With the pump running and air purge valve open, water will begin to flow into the pump releasing air from the
    system. This process will take about 30 seconds depending on the amount of the water in the spa and the pump.
3. When water begins to flow from the opening of the air purge valve, close the valve and dry any excess water 
    from the surface of the pump.

PUMP OPERATION

Control Panel

Heat Button:

 Use this button to activate the heating system, and the Lay-Z-Massage System will shut off automatically.

The pump will heat the spa water until the water temperature reaches 1°C (1.8°F)  higher than the input desired  temperature.
After the current water temperature drops 2°C (3.6°F) below the input desired temperature the heating system will restart.
When the light above the heat button is red, the heating system is activated. When the light is green, the water is at the input 
desired temperature and the heating system is at rest.
The #54075 rapid heating system is capable of increasing water temperature by approximately 1.5 to 
2°C (3-4°F) per hour.
The #54090 rapid heating system is capable of increasing water temperature by approximately 1°C (1.8°F) per hour.

NOTE:

 If the heating system is activated the filtration system will automatically start.

NOTE:

 After turning off the heating system the filtration system will continue to operate.   

Lay-Z-Massage Button:

 Use this button to activate the massage system which has a 30-minute auto shut off feature and the 

heating system will shut off automatically.
The light above the Lay-Z-Massage Button displays green when activated.

WARNING:

 Do not run the Lay-Z-Massage system when the cover is attached, air can accumulate 

inside the spa and cause irreparable damage and bodily harm.

After 24 hours of operation,the pump will hibernate. “End” will be displayed on the LED.When the pump is hibernating both the 
rapid heating and water filtration functions are disabled.To re-active the pump simply press any buttons on the control panel.

Temperature Mode Button:

 The temperature can be displayed in either Fahrenheit or Celsius. To toggle between these 

choices simply press this button. 

NOTE:

 The system’s default is Celsius.

LED Display: 

Once powered-up the LED displays the current water temperature automatically. 

Temperature Adjustment Buttons:

            

Pressing the Temperature Increase or Temperature Decrease buttons will cause the LED to flash. When flashing you can adjust 
to the desired temperature setting.  If you hold these buttons down the values will rapidly increase or decrease.The new and 
desired temperature setting will remain on the LED display for 5 seconds to confirm the new value.

NOTE:

 The default temperature is 40°C(104°F) when first plugged in. 

NOTE:

 Temperature adjustment ranges from 20°C (68°F) to 40°C (104°F).

Water Filtration Button: 

This button turns the filter pump on and off. 

The light above the Water Filtration Button displays green when activated.

A: Temperature Increase Button

B: Temperature Decrease Button

C: Heat Button

D: Lay-Z-Massage Button

E:  Water Filtration Button

F: Temperature Mode Button

G: LED Display

E

S-S-000830

!ƚ)ϸƔ

Summary of Contents for 54075

Page 1: ...sales bestway europe com www bestway service com Austria Alois Grabner K G Bahnhofstr 32 A 8714 Kraubath Österreich Austria Tel 00 800 660 041 00 E mail bestway grabner pools com Belgium Tel 0 800 20 132 Fax 32 28080882 E mail belgiumservice bestway europe com Denmark Scanditoy A S Hørkær 18 1 sal 2730 Herlev Denmark Tel 45 47 31 48 00 Fax 45 47 31 66 08 E mail denmark bestway service com Finland ...

Page 2: ...S S 000830 ...

Page 3: ...uctions 2 Specifications 3 Installation Instructions 4 Pump Operation 5 Maintenance 6 Troubleshooting 7 Disposal 8 Warranty P2 3 P3 7 P8 9 P9 10 P11 P11 P12 P3 220 240V 50Hz 2050W Hmax 1 0m Hmin 0 19m IPX5 S S 000830 ...

Page 4: ...be exercised to prevent unauthorized access by children To avoid accidents ensure that children can not use this spa unless they are supervised at all times WARNING RISK OF INJURY Never operate spa if the suction fittings are broken or missing Never replace a suction fitting WARNING RISK OF ELECTRIC SHOCK Install at least 1 5m from all metal surface WARNING RISK OF ELECTRIC SHOCK Never operate any...

Page 5: ...amage to the pump the spa must never be operated unless the spa is filled with water CAUTION Immediately leave spa if the user feels uncomfortable or sleepy CAUTION Never add water to chemicals Always add chemicals to water to avoid strong fumes or violent reactions that may result in hazardous chemical spray NOTE Please examine equipment before use Notify Bestway at the customer service address l...

Page 6: ...portant you have a solid support foundation If you are installing the Lay Z Spa in an outdoor area ensure there are no sharp objects that could damage it and that the location is level so the Lay Z Spa sits properly During filling draining or when in use water may spill out of the spa Therefore the Lay Z Spa should be installed near a floor drain Do not leave the spa s surface exposed to direct su...

Page 7: ...e inflate the chambers according to the printed numbers 1 2 3 4 5 5 Connect the pump to the spa by lining up the matching letters A to A B to B and C to C and using the adapters to connect the pump to the spa Ensure the seals are properly in place and hand tighten the adapters securely 6 Fill the spa using a garden hose Fill the spa minimum water level to the water level printed on the spa wall 7 ...

Page 8: ... 7 1 2 2 4 4 8 4 2 2 3 4 5 6 7 NO NAME QTY Table Clip B Clip A Locking pin Table Support Beam U support 2 Beam 3 6 1 4 Using the SID Valve Screw the SID Valve onto the air intake valve 6 Using the inflation hose inflate the spa chambers according to the printed number 1 2 3 4 5 7 Insert the U Supports through the pool support sleeve at the bottom of the spa insert the two ends of the U Supports in...

Page 9: ...to position Repeat this step for the opposite table 12 WARNING This spa cover is not a substitute for adult supervision child must be supervised at all times around the spa WARNING Do not run the Lay Z Massage system when the cover is attached air can accumulate inside the spa and cause irreparable damage and bodily harm 14 Connect the pump to the spa by lining up the matching letters A to A B to ...

Page 10: ...ature by approximately 1 C 1 8 F per hour NOTE If the heating system is activated the filtration system will automatically start NOTE After turning off the heating system the filtration system will continue to operate Lay Z Massage Button Use this button to activate the massage system which has a 30 minute auto shut off feature and the heating system will shut off automatically The light above the...

Page 11: ...utlined steps test the RCD PRCD plug bleed the air purge valve and restart the pump P4014Q09 01 01 P4014Q09 01 03 P4014Q09 01 04 Unplug the pump When the water cools restart If this does not solve the problem please consult Bestway or your dealer The LED displays The LED displays and all the lights flash The LED displays and all the lights flash The LED displays and all the lights flash The LED di...

Page 12: ...onto the spa s inside adapter and skimmers 2 Disconnect the pump from the spa 3 Connect the hose adapter to your garden hose and attach the hose adapter to the spa s B adapter 4 With your hose positioned in a selected drain area remove the lower stopper cap from inside the spa to release the water Once the spa water has been drained below the spa s bottom air chamber unscrew the SID Valve counter ...

Page 13: ...proper water levels Forget to remove the 3 Stopper Caps Heating element failed Set to a higher temperature Clean replace the Filter Cartridge in time Add water to specified levels Remember to remove the 3 Stopper Caps before heating Call for service Lay Z Massage System does not work Pump is too hot 30 minute auto shut off feature activated Something is wrong with the Pump Unplug the Pump After th...

Page 14: ...__________ Customer Code Number ___________ FAX E MAIL TEL Please refer to your country according to the information you find on the back cover Spa leaking RCD PRCD GFCI tripped Control panel shows the failure which can not be solved Water Filtration System not working Lay Z Massage System not working Heating System not working Pump leaking Adapter leaking Missing Parts Please use the code for the...

Page 15: ...ntrôle Messages d erreur P14 15 P15 P21 23 5 Entretien Nettoyage et remplacement de la cartouche du filtre Entretenir de l eau du Spa Drainage du Spa Nettoyage du Spa Réparation du Spa Rangement du Lay Z Spa P23 P23 P24 13 1 Consignes de sécurité 2 Spécifications 6 Dépannage 7 Démontage 8 Garantie MANUEL DU PROPRIÉTAIRE 220 240V 50Hz 2050W Hmax 1 0m Hmin 0 19m IPX5 Ta b le d e s matiè r e s S S 00...

Page 16: ...nger de noyade Ne pas laisser d enfants s approcher sans autorisation Pour éviter les accidents assurez vous que les enfants ne puissent jamais utiliser le spa sans surveillance AVERTISSEMENT RISQUE DE BLESSURE Ne jamais mettre le spa en marche si les dispositifs d aspiration sont cassés ou absents Ne jamais remplacer un dispositif d aspiration AVERTISSEMENT DANGER D ÉLECTROCUTION Installer à au m...

Page 17: ...violentes susceptibles de provoquer des évaporations dangereuses REMARQUE bien examiner l équipement avant usage Informez Bestway à l adresse du service clientèle répertoriée dans ce manuel en cas de dommage ou pièces manquantes au moment de l achat Vérifiez que les composants de cet équipement correspondent bien au modèle que vous avez voulu acheter REMARQUE Il ne faut pas faire fonctionner la po...

Page 18: ...sissure de l air sur le bois le papier etc du lieu préposé Pour minimiser ces effets prévoir un maximum de ventilation dans la zone choisie Un architecte peut vous aider à définir si plus de ventilation est nécessaire REMARQUE n installez pas le Lay Z Spa sur la moquette ou autre matière pouvant être endommagée par la moisissure 2 Installation à l extérieur Peu importe où vous installez le Lay Z S...

Page 19: ...sez le spa au niveau d eau minimum imprimé sur la paroi du spa 7 Placez la bâche en cuir factice sur le spa et fermez la fermeture éclair 17 Vissez la valve SID sur la valve d entrée de l air Ouvrir le bouchon de la valve SID introduire le tuyau de gonflage et gonfler Une fois le gonflage terminé resserrer le bouchon de la valve SID Pour dégonfler il suffit de dévisser la valve SID dans le sens in...

Page 20: ...mpe 7 1 Utilisation de la valve SID Pôles support 6 A l aide du tuyau de gonflage gonflez les chambres du spa en suivant les numéros imprimés 1 2 3 4 5 7 Insérer les supports en U à travers le support de la piscine au bas du spa insérer les deux extrémités des supports en U dans les orifices de la poutrelle et fixer les linguets à ressort en position Répéter cette procédure de l autre côté du spa ...

Page 21: ...her le Spa sans surveillance AVERTISSEMENT Ne faites pas fonctionner le système de Lay Z Massage quand la bâche est présente l air pourrait s accumuler à l intérieur du spa et provoquer des dommages irréparables et des dommages corporels 14 Branchez la pompe au spa en faisant correspondre les lettres A avec A B avec B et C avec C et en utilisant les adaptateurs pour brancher la pompe au spa Vérifi...

Page 22: ... chauffe est au repos Le système de chauffage rapide 54090 est capable d augmenter la température d environ 1ºC 1 8ºF par heure Le système de chauffage rapide 54075 est capable d augmenter la température d environ 1 5 à 2ºC 3 4ºF par heure REMARQUE lorsque le système de chauffe est activé le système de filtration démarre automatiquement c est normal REMARQUE après avoir éteint le système de chauff...

Page 23: ...é du bouchon de la pompe Bouchon de la pompe Joint du bouchon de la pompe 58094 P4014 04 19 P4014 01 27 P4014 01 27 Cartouche du filtre Joint de l adatateur A Joint de l adatateur C Joint de l adatateur B Débrancher la pompe Lorsque l eau refroidit redémarrer si cela ne résout pas le problème consultez nous ou consultez votre revendeur Le LED affiche Le LED affiche et tous les voyants clignotent L...

Page 24: ...uire les trois bouchons d arrêt sur l adaptateur interne du Spa et lesrécupérateurs 2 Débrancher la pompe du Spa 3 Relier l adaptateur de l embout au tuyau d arrosage et le fixer à l adaptateur B du Spa 4 Une fois le tuyau installé à l endroit choisi retirez le bouchon d arrêt pour évacuer l eau Une fois que le niveau de l eau descend en dessous de dernière chambre du Spa dévisser la valve SID dan...

Page 25: ...ublié d enlever les 3 bouchons d arrêt panne de l élément de réchauffement Programmer une température plus élevée Nettoyer changer la cartouche du filtre à temps Ajouter l eau jusqu aux niveaux indiqués Rappelez vous d enlever les 3 bouchons d arrêt avant le réchauffement Appelez pour l assistance Le système de massage Lay Z ne fonctionne pas La pompe est trop chaude la fonction de système d arrêt...

Page 26: ... ATTENTION DE Service Après Vente Bestway DATE ________________ Numéro de code client _______ FAX E MAIL TÉL Se reporter au numéro correspondant à votre pays présent sur le verso du manuel Fuite d eau dans le spa RCD PRCD GFCI enclenché Le panneau de contrôle affiche une défaillance qui ne peut pas être résolue Le système de filtration de l eau ne fonctionne pas Le système de massage Lay Z ne fonc...