background image

6

POOL SUCTION FITTING 

INSTRUCTIONS

When installing and using this equipment, basic safety precautions shall always be 

followed, including the following:

IMPORTANT SAFETY INSTRUCTIONS

READ, FOLLOW, AND UNDERSTAND 

ALL INSTRUCTIONS AND WARNINGS.

- Any modification that increases the flow rate of the circulation system shall require 

re-evaluation of the cover/grate and sump to ensure that the flow rating of the Suction 

Outlet Fitting Assembly (SOFA) is not exceeded.

- Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA 

component shall be replaced before bathers are allowed to use the pool.

- Loose cover/grates shall be reattached before bathers are allowed to use the pool.

1. Replace suction fittings every 2 years.

2. The use of adhesives or other attachment methods 

that prevent access to suction piping or SOFA 

components requiring periodic servicing is prohibited. 

3. Refer to the following diagram for each SOFA 

component part instructions:

4. - Any field modification made to a SOFA not 

authorized by the manufacturer’s installation 

instructions shall void the SOFA certification.

 - No modification shall be made to a SOFA structure 

or flow path unless the new configuration has been 

certified as new SOFA.

 - Cover/grates and all other SOFA components shall 

be replaced at or before the end of their service life and that service life begins the 

month and year in which a SOFA component is installed with or without water.

5. Winterizing instructions. Dry the suction fittings completely

and store the product in a 

dry room at a storage temperature of 15 

℃ 

~ 40 

.

6. Use the screwdriver (not included) to disassemble the suction fitting to clean or service.

- Cover/grate, including fasteners, shall be observed for damage or tampering each 

operational day.

- Missing, broken, or cracked cover/grates shall be replaced before bathers are allowed 

to use the pool.

- Loose cover/grates and associated components shall be reattached before bathers are 

allowed to use the pool.

- SOFA components and fastener receptacles shall be clean and free of debris or 

obstructions during installation of cover/grate and fasteners.

- Remember to hand-check cover/grate for snugness to the sump/ frame after 

installation.

7. Before using the product, please check the integrity of the head of the suction fitting. If 

the product is broken, please do not use it.

8. - All SOFAs shall be installed in accordance with the manufacturer’s installation 

instructions.

- No modification shall be made to a SOFA structure or flow path unless the new 

configuration has been certified to the original SOFA.

- These SOFA-configuration specific flow ratings NOT be exceeded at any time the pool 

is open to bathers.

- Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from the 

finished surface of the pool in which the SOFA is installed

9. 

Please research and download General Certificate of Conformity through 

www.bestwaycorp.com

SAVE THESE INSTRUCTIONS

Installation Information label (copy)

Manufacturers name: 

GOLEADER INDUSTRIES (JINHUA) CO., LTD. 

Cover part number: F4030

Service life of the cover: 2 Years

Cover flow rating: 28 GPM 

Installer need to fill in the balance of information and 

give it to the pool owner, to be kept with other important 

pool related documents.

Configuration and installed orientation:_________

Location:_______

Installed Date:_________

Summary of Contents for 58511E

Page 1: ...Bestway YouTube channel WE SUGGEST NOT TO RETURN THE PRODUCT TO THE STORE QUESTIONS PROBLEMS MISSING PARTS For FAQ Manuals Videos Or Spare Parts Please Visit bestwaycorp com support V i s i t w w w be...

Page 2: ...ed service representative before using CAUTION To reduce the risk of electric shock the pool must be installed no closer than 6 feet 1 8 m from any electrical outlet Do not place portable appliances c...

Page 3: ...attention to position of pool and pump so adequate ventilation drainage and access for cleaning is available Never place pump in an area that may accumulate water or in an area where foot traffic wil...

Page 4: ...interference received including interference that may cause undesired operation WARNING Any changes or modifications to this unit not expressly approved by the party responsible for compliance could...

Page 5: ...he following diagram for each SOFA component part instructions 4 Any field modification made to a SOFA not authorized by the manufacturer s installation instructions shall void the SOFA certification...

Page 6: ...original SOFA These SOFA configuration specific flow ratings NOT be exceeded at any time the pool is open to bathers Cover grates when installed shall not protrude more than 2 in 51 mm from the finis...

Page 7: ...3 X2 X1 X1 A B P6362ASS16 P6132ASS16 P6132ASS16 1 3 2 4 B B A A B A B B A B A B P61318ASS16 P6680ASS16 B B A X2 P6124ASS16 A B C P05426 P6 H1 114ASS16 P6118ASS16 58093 P61958US P6019ASS16 P6132ASS16 P...

Page 8: ...and turn clockwise to rethread air purge valve 2 When water comes out of the Air Purge Valve screw it closed and wipe away any water 3 Test the GFCI plug PEDESTAL FIXING The filter pump must be vertic...

Page 9: ...me time the following day 2 In case of a power outage or the GFCI being unplugged the running time of the product will be reset to a 10 hour default and the previous set will be deleted 3 After finish...

Page 10: ...estwaycorp com support 2021 Bestway Inflatables Material Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Tutti i diritti riservati Trademarks used i...

Reviews: