2
WARNING
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
–
TO REDUCE THE RISK OF INJURY,
do not permit children to
use this product unless they are closely supervised at all times.
WARNING
–
RISK OF ELECTRIC SHOCK
–
The pump must be supplied by
an isolating transformer or supplied through a residual current device(RCD)
having a rated residual operating current not exceeding 30mA.
WARNING
–
RISK OF ELECTRIC SHOCK
–
The pump must be supplied by
an isolating transformer or supplied through a circuit of alternative residual
power (DDR) 30mA maximum. (For France Only)
WARNING
–
RISK OF ELECTRIC SHOCK
–
The pump cannot be using
while people are inside the pool. Forbid the access of the pool in case of
damage of the filter pump.
DO NOT BURY CORD.
Locate cord to minimize abuse from lawn
mowers,hedge trimmers,and other equipment.
WARNING
–
To reduce the risk of electric shock,
IF FILTER PUMP POWER
CORD BECOMES DAMAGED IN ANY WAY, THE PUMP MUST BE
DISCARDED.
WARNING
–
To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION
–
This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable
of being readily disassembled for storage and reassembled to its original
integrity. A permanently-installed pool is constructed in or on the ground or in
a building such that it cannot be readily disassembled for storage.
IMPORTANT
–
Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRICAL SHOCK
–
When working with electricity, turn the
electrical power off at the circuit breaker and lock breaker door. Failure to do
so will result in increased risk of shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN
ANY WAY. DO NOT USE ADAPTOR PLUGS.
Consult a qualified electrician
for any questions related to the validity of your plugs grounding.
Handle the pump with care. Do not pull or carry the pump by the power cord.
Never pull a plug from the outlet by yanking the power cord. Keep cord
free from abrasions. Sharp objects, oil, moving parts, and heat should never
be exposed to the filter pump.
WARNING
– This appliance is not intended for use by persons (Including
children) with reduced physical, sensor or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the
appliance.
NOTE:
Please examine equipment before use. Notify Bestway at the
customer service address listed on this manual for any manufacturing defect
or missing parts at the time of purchase. Verify that the equipment
components represent the filter pump model that you had intended to
purchase.
NOTE:
Place pump on a solid and level ground. Pay attention to position of
pool and pump so adequate ventilation, drainage, and access for cleaning is
available. Never place pump in an area that may accumulate water, or in an
area where foot traffic will flow around the pool.
Please ensure the filter pump is at least 2 meters away from the pool side.
(For France only)
It is necessary to have the plug accessible after installation of the pool.
The plug of pump shall be at least 3,50m away from the pool. (For France
only)
Electric installations should fulfill the requirements of standards NFC 15-100.
(For France only)
NOTE:
Atmospheric conditions may affect the performance and life span of
your filter pump. Unnecessary wear and tear may occur during periods of
cold, heat and exposure to sun. Whenever possible shelter pump from these
conditions.
It is important to ensure the factory equipped stopper plugs for the inlet and
outlet ports replace the screens before removal or maintenance on the pump
is attempted.
It is imperative to change as soon as possible all the deteriorated parts. Only
use the parts approved by the manufacturer.
NOTE:
Do not run the pump more than 15 hours per day.
When chemical products are used to clean the pool water, it is recommended
to respect a minimum filtration time to preserve the health of swimmers which
depends on compliance of health regulation.
NOTE:
Do not add chemicals in the filter pump.
SAVE THESE INSTRUCTIONS.
Pump Installation Directions
NOTE:
Assembly requires a straight screwdriver.
PART I
Internal Filter Pump Inspection
1) Remove the Filter Cap by unscrewing the Filter Cap Retainer.
2) Inspect the Filter Cartridge ensuring it is centered in the Filter Pump.
3) After inspection, check that the Filter Cap Seal is in place, replace the Filter
Cap and screw the Filter Cap Retainer into position.
PART II
Attach the Hoses to the Filter Pump and the Pool
1) Place the loose Hose Clamps on both the ends of the Hoses.
2) Attach the Hoses to the corresponding letters on both the pool and the
Filter Pump (A to A, B to B).
3) Tighten the Hose Clamps to the Filter Pump by screwing the fly nut
clockwise .
4) Remove the Stopper Plugs from the pool’s Inlet and Outlet Valves and
insert the Debris Screens.
5) With the Hoses and the Debris Screens in position, tighten the Hose
Clamps.
NOTE:
It is important to ensure all elements: Hoses, Debris Screens and
Inlet/Outlet Valves are properly aligned.
NOTE:
After pump is attached to pool, refer to pool manual for filling
instructions.
NOTE:
It is imperative to check that the hydraulic connectors are not
obturated.
Pedestal Fixing
EN60335-2-41 TEST standard requires the filter pump must be vertically fixed
on ground or a certain pedestal made of wood or concrete before use. There
should be two holes 9mm in diameter on the pedestal, the space between
which should be 162mm. Put filter pump on the pedestal and fix them together
by fasten the bolts and nuts. All the pedestal parts should weigh over 18kgs at
least to prevent the pump from accidental falling.
390 162
390
250
162
2-M8 bolt
2-M8 nut
PART III
Preparing the System for Use
1) Open/unscrew the Air Purge Valve on the top of the Filter Pump; air is
released as water fills the Filter Pump.
2) When water comes out of the Air Purge Valve screw it closed and wipe
away any water.
3) To start the Filter Pump, Insert the plug of the filter pump to a residual
current device (RCD). To start the Filter Pump, Insert the plug of the filter
pump to a circuit of alternative residual power (DDR)-For France Only.
NOTE:
To prevent the risk of electrical shock, ensure your hands are
completely dry when plugging-in the Filter Pump.
NOTE:
To prevent the risk of electrical shock, never run the Filter Pump
when people are swimming in the pool.
IMPORTANT:
DO NOT DRY RUN THE FILTER PUMP –
Make sure both
the pool’s Inlet and Outlet valves are fully covered by water before
operating the Filter Pump.
Pump Installation Diagram
PUMP MAINTENANCE
CAUTION:
YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED
BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR
DEATH EXISTS.
Take action to avoid using pools if the filter has problem.
Check the suction if there is any blocking.
Replace all the damaged components.
Part I
Stop Water Flowing to the Filter Pump
1) Unplug the Filter Pump.
2) Loosen the Hose Clamps on the pool’s Inlet and Outlet Hoses by
unscrewing the fly nut counter-clockwise.
3) Remove Debris Screens from inside of pool.
4) Replace the Debris Screens with the Stopper Plugs in the pool’s Inlet and
Outlet Valves.
Part II
Cleaning/Replacing the Filter Cartridge
Do not use product during filter cartridge maintenance.
Check filter cartridge regularly.
1) Unscrew the Filter Cap Retainer and remove the Filter Cap.
2) Clean the Filter Cartridge with a garden hose.
NOTE:
If filter cartridge remains soiled or discolored, replacement is
necessary.
Illustration (not to scale) of pool and filter-pump
Hose connection
Water level
>1/2 inches
inside wall
Pool
F4030
P6124
P6112
P6124
P6124
Inlet
Water flow
Water flow
Outlet
A
A
B
B
2m (For France only)
S-S-001180
S-S-001180/14.0x21.0cm(#58117/#58118/B
版
) JS-YF-2011-B-02226/
英