INSTALLATION

RECOMMENDATIONS DURING THE INSTALLATION

• Keep the spa away from the rest area to minimize noise disturbance.

• Keep at least 1m clearance around the spa.

• We don't recommend using sea water to fill the pool. Sea water can corrode the internal metal components due to the high concentration of salt.

• The filtration system of the spa is designed to be used only with the filter cartridge. Any other component added inside the filter set can cause damage 

to the filtration system of the spa. This will not be covered by customer service.

INFLATION INFORMATION 

Only For Inflatable Spa Liner or Cover:

• When inflating, you will notice that air will be expelled from the area where the air hose connects to the pump, this is 

normal for technique requirements.

• Don't cover the holes on the base of the inflation hose. This operation will over inflate the liner and damage the 

structure.

• Do not use an air compressor to inflate the spa.

• Do not drag the pool on rough ground as this may cause damage to the spa liner. Inflation time for reference only.

HAND PUMP PRESSURE GAUGE

Only For Drop Stitch Spa:

• The air pressure gauge of the hand pump only shows the air pressure higher than 5 psi, which is normal. When the air 

pressure in the product is lower than 5 psi, the air pressure gauge will not show a value.

AIR VALVE CHECK

Only For Drop Stitch Spa

• If the air valve is loose, use the provided wrench to fasten the air valve following these steps: With one hand, hold the backside of the air valve from the 

inner side of the spa wall and turn the wrench clockwise.

• Do not adjust the air valve connector when the spa is in use.

USING THE SPA

LOCK/UNLOCK BUTTON:

 The pump has a 5-minute auto-lock, this light will turn on. To lock or unlock the pump, press the lock/unlock 

button for 3 seconds. 

HEAT BUTTON: 

Press      button to activate the heating system. When the light of the      button is red, the heating system is activated. 

When the light is green, the water reached the set temperature.

If the heating system is activated, the filtration system will automatically start.

After turning off the heating system, the filtration system will continue to operate.

MASSAGE SYSTEM BUTTON: 

Press      button to activate the massage system, which has a 30-minute auto-shutoff feature. The light of 

the button becomes red when activated.

Do not run the massage system when the cover is attached, air can accumulate inside the spa and cause irreparable damage to the cover. 

Heat and massage system can be activated at the same time.

FOR SPA EQUIPPED WITH Wi-Fi ONLY

2-LEVEL MASSAGE REGULATION:

 Push once for the full power massage, push again to stop, push again for lower power massage,

and push again to shut off.

When inflating the spa liner, make sure that the massage function is running at full power.

Press the      button and the      LED starts to flash.

Press the      or      button to adjust the heating duration (From 1-999 hours).

Press the      button again to confirm the heating duration.

After setting the heating duration, the      LED starts to flash.

Press the      or      button to set the time (From 0-999 hours). This setting defines the waiting hours before the activation of the heating 

function. If the timer is set to 0 hour, the heating system will activate immediately.

Press      button again or simply touch nothing for 10 seconds to confirm the setting. The      LED will light steadily, and the countdown to 

heater activation will begin. The screen flashes the current temperature and time alternately.

To modify the timer settings: Press the      button and use the      or      button to adjust.

Cancel the setting: Press the      button for 2 seconds.

When the power saving function is activated, all other functions (massage, filtration) except the heating can be used.

The POWER-SAVING function in not an automatic function: after one complete cycle (waiting time plus heating function), this function must 

set again.

POWER-SAVING TIMER BUTTON:

 Designed to help avoid wasting power by setting the time and duration of the heating cycle for the spa. 

follow these steps to activate the POWER-SAVING function.

CONTROL PANEL

AIRJET

AIRJET WITH Wi-Fi 

For the installation instructions, follow the drawings printed on the package. Drawings are for illustration purposes only. May 

not reflect actual product. Not to scale.

Summary of Contents for LAY-Z-SPA S100203

Page 1: ...ieben und in der Europäischen Union vertreten von Prodotto distribuito e rappresentato nell Unione Europea da Bestway Europe S p a Via Resistenza 5 20098 San Giuliano Milanese Milano Italy Distributed in Latin America by Distribué en Amérique latine par Distribuido en Latinoamérica por Distribuído na América Latina por Bestway Central South America Ltda Salar Ascotan 1282 Parque Enea Pudahuel Sant...

Page 2: ... addition the following information can be supplied depending on the spa type Keep these instructions in a safe place If instructions are missing please contact the manufacturer or search it on the website www bestwaycorp com IMPORTANT SAFETY INSTRUCTIONS PRE SETUP INSTALLATION USING THE SPA MAINTENANCE DISASSEMBLY AND STORAGE TROUBLESHOOTING ERROR CODES pg 002 pg 006 pg 009 pg 009 pg 011 pg 011 p...

Page 3: ...uld not exceed 40 C 104 F Never wear your contact lenses when in your spa Do not use spa during chemical maintenance The power source on the wall of building should keep more than 4m away from pool and at a height of 1 2m at least Extension cords can t be used Don t plug or unplug the appliance if hand is wet Always unplug the appliance on rainy days before cleaning or other maintenance if leave i...

Page 4: ...res are recommended for young children and when spa use exceeds 10 minutes B Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperature to 38 C 100 F C Before entering a spa the user should measure the water temperature with an accurate thermometer since the tolerance ...

Page 5: ...r to avoid a hazard due to inadvertent resetting of the thermal cut out this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility After using your spa for 3 5 years you should contact your local qualified maintenance technician to ensure the safety and performance of the spa The main compo...

Page 6: ...he combined weight of the water inside the spa and the users it is extremely important that the surface chosen to install the spa is capable of uniformly supporting the total weight for the entire time the spa is installed An adequate drainage system has to be provided to deal with overflow water for both indoor and outdoor installations During filling draining or when in use water may flow out of...

Page 7: ...ce that does not meet the above set up conditions Indoor Installation Be aware of special requirements if you install the spa indoors Humidity is a natural side effect with Lay Z Spa installation Determine the effects of airborne moisture on exposed wood paper etc in the proposed location To minimize these effects it is strongly recommended to provide plenty of ventilation to the selected area Con...

Page 8: ...G TERMINAL It is recommended to arrange for a qualified electrician to connect the spa pump to an equipotential bonding terminal using a minimum 2 5mm2 solid copper conductor HEATING RESET When using the Lay Z Spa for first time or after a long period of inactivity be sure to press the reset button on the pump using a small and thin object If the temperature on the control panel or the water tempe...

Page 9: ...ating system is activated the filtration system will automatically start After turning off the heating system the filtration system will continue to operate MASSAGE SYSTEM BUTTON Press button to activate the massage system which has a 30 minute auto shutoff feature The light of the button becomes red when activated Do not run the massage system when the cover is attached air can accumulate inside ...

Page 10: ...on leaflet included in the package WINTER USE INSTRUCTIONS SPA HEATER SPECIFICATION Ambient Temperature 10ºC 50ºF 15ºC 59ºF 20ºC 68ºF 25ºC 77ºF 30ºC 86ºF Water Temperature 10ºC 50ºF 15ºC 59ºF 20ºC 68ºF 25ºC 77ºF 30ºC 86ºF Set Temperature 40ºC 104ºF 40ºC 104ºF 40ºC 104ºF 40ºC 104ºF 40ºC 104ºF Heating Duration 16 24h 12 20h 10 18h 8 12h 5 8h Power Rate Massage Tube Power Heat Element Power Water Pum...

Page 11: ...h care There are serious health risks from chemical vapors and the incorrect labeling and storage of chemical containers Please consult your local pool or chemical supply retailer for more information about chemical maintenance Pay close attention to the chemical manufacturer s instructions Over usage of chemicals will discolor the printing and all points of the spa material in the worst case it w...

Page 12: ...tenance Please consult your local chemical supplier for information about chemical maintenance Pay close attention to the chemical manufacturer s instructions Water leaks from the adapters between the pump and spa Insert the stopper caps on the spa ports to prevent the water from escaping and disconnect the pump Check if the seals are in place If the seals are not in the correct position open the ...

Page 13: ...or the router that creates signal interference The Wi Fi connectivity can be interrupted by electromagnetic or other interferences Keep the appliance away from other electronic devices that may cause interferences Your phone will not connect to the Wi Fi network during the registration Check if the mobile device is in airplane mode Make sure to have the airplane mode deactivated when connecting to...

Page 14: ...couplings and remove the washer for further inspection For assistance please visit the support section on our website www bestwaycorp com The pump s thermometer reads the water temperature below 4 C 40 F 1 The water temperature is lower than 4 C 40 F 2 If the water temperature is higher than 7 C 44 6 F the pump s thermometer is broken 1 The spa is not designed to operate with water temperatures lo...

Page 15: ...303021293193_14x21cm_23季澳规AirJet AirJet Plus SPA说明书 15 1 2 3 3 5 4 1 2 2 1 RESET TEST RESET TEST 2 2 RESET TEST 2 3 RESET TEST 2 4 5 h ...

Page 16: ...303021293193 A 16 1 B 2 3 1 2 3 1 2 b 3 303021293193_14x21cm_23季澳规AirJet AirJet Plus SPA说明书 a ...