background image

WARNING

IMPORTANT SAFETY INSTRUCTIONS

When using this electrical equipment, basic safety precautions should always be 

followed, including the following:

READ AND FOLLOW ALL INSTRUCTIONS.

WARNING – 

To reduce the risk of injury, do not permit children to use this 

                           product unless they are closely supervised at all times.

A wire connector is provided on this unit to connect a minimum 8 AWG (8.37 mm

2

solid copper conductor between this unit and any metal equipment, metal enclosures 

of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.

DANGER – 

Risk of injury.

a) Replace damaged cord immediately.

b) Do not bury cord.

c) Connect to a grounded, grounding type receptacle only.

WARNING – 

This product is provided with a ground-fault circuit-interrupter  

                           integrated with the power plug at the end of the cord. The GFCI 

must be tested before each use. With the product operating, push the test button on 

the GFCI and the product should not operate. Push the reset button on the GFCI and 

the product should now operate normally. When the product fails to operate in this 

manner, there is a ground current flowing indicating the possibility of an electrical 

shock. Disconnect the power until the fault has been identified and corrected.

DANGER – 

Risk of Accidental Drowning. Extreme caution must be exercised to

                         prevent unauthorized access by children. To avoid accidents, ensure 

that children cannot use this spa unless they are supervised at all times.

DANGER – 

Risk of Injury. The suction fittings in this spa are sized to match the 

                         specific water flow created by the pump. Should the need arise to 

replace the suction fittings or the pump, be sure that the flow rates are compatible. 

Never operate spa if the suction fittings are broken or missing. Never replace a 

suction fitting with one rated less than the flow rate marked on the original suction 

fitting.

DANGER – 

Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal

                         surfaces. As an alternative, a spa may be installed within 5 feet of 

metal surfaces if each metal surface is permanently connected by a minimum 8 AWG 

(8.37 mm

2

) solid copper conductor to the wire connector on the terminal box that is 

provided for this purpose.

DANGER – 

Risk of Electric Shock. Do not permit any electric appliance, such as a

                         light, telephone, radio, or television, within 5 feet (1.5 m) of a spa.

WARNING – 

To reduce the risk of injury:

a) The water in a spa should never exceed 104°F (40°C). Water temperatures 

between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult. 

Lower water temperatures are recommended for young children and when spa use 

exceeds 10 minutes.

b) Since excessive water temperatures have a high potential for causing fetal 

damage during the early months of pregnancy, pregnant or possibly pregnant 

women should limit spa water temperatures to100°F (38°C).

c) Before entering a spa, the user should measure the water temperature with an 

accurate thermometer since the tolerance of water temperature-regulating devices 

varies.

d) The use of alcohol, drugs, or medication before or during spa use may lead to 

unconsciousness with the possibility of drowning.

e) Obese persons and persons with a history of heart disease, low or high blood 

pressure, circulatory system problems, or diabetes should consult a physician 

before using a spa.

f ) Persons using medication should consult a physician before using a spa since 

some medication may induce drowsiness while other medication may affect heart 

rate, blood pressure, and circulation.

WARNING: 

TO AVOID ELECTRIC SHOCK, DO NOT USE THE SPA WHEN IT IS

                         RAINING.

WARNING: 

Water attracts children; Always attach a spa cover after each use.

WARNING: 

TO REDUCE THE RISK OF INJURY: Never add water that is higher

                         than 104°F (40°C) into the Spa.

CONSULT YOUR PHYSICIAN FOR 

RECOMMENDATIONS.

CAUTION:

We strongly recommend not to unfold and inflate the spa if the ambient temperature 

is below 59°F(15°C). We suggest inflating the spa indoors, and then continuing set 

up outdoors. If the outdoor temperature is lower than 42.8°F(6°C), the spa heater 

must always be on. In this mode, the Freeze Shield™ system can keep the internal 

temperature between 42.8°F(6°C) and 50°F(10°C) to prevent damage, such as water 

freezing in the pipes or the circulation system. 

IMPORTANT: 

If the Freeze Shield™ system isn’t working, alarms will pop up on

                             the spa. Be sure to check the status of your spa if the outdoor 

temperature is below 42.8°F(6°C). In case of a long-term absence from home when 

there is a risk of temperatures falling below 42.8°F(6°C), we strongly suggest 

disassembling the spa and storing it following the storage procedure.

CAUTION: 

Do not use the spa alone.

CAUTION: 

Always enter and exit the spa slowly and cautiously. Wet surfaces are

                       slippery.

CAUTION: 

To avoid damage to the pump, the spa must never be operated unless

                       the spa is filled with water.

CAUTION: 

Immediately leave spa if the user feels uncomfortable or sleepy.

NOTE: 

Please examine equipment before use. Notify Bestway

®

 at the customer 

               service address listed on this manual for any damaged or missing parts at 

the time of purchase. Verify that the equipment components represent the model that 

you had intended to purchase.

This device complies with part 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference, and 

(2) this device must accept any interference received, including interference that may 

cause undesired operation.

Any changes or modifications to this unit not expressly approved by the party 

responsible for compliance could void the user’s authority to operate the equipment.

NOTE: 

This equipment has been tested and found to comply with the limits for a

               Class B digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses and can radiate radio 

frequency energy and, if not installed and used in accordance with the instructions, 

may cause harmful interference to radio communications. However, there is no 

guarantee that interference will not occur in a particular installation. If this equipment 

does cause harmful interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user is encouraged to try to 

correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and receiver.

- Connect the equipment into an outlet on a circuit different from that to which the 

receiver is connected.

- Consult the dealer or an experienced radio/TV technician for help. 

4

Summary of Contents for SaluSpa

Page 1: ...OWNER S MANUAL ...

Page 2: ...AINTENANCE pg 021 DISASSEMBLY AND STORAGE pg 023 TROUBLESHOOTING pg 025 ERROR CODES pg 026 FOR INSTRUCTION VIDEOS PLEASE VISIT BESTWAYCORP COM SUPPORT CONTENTS WE SUGGEST NOT TO RETURN THE PRODUCT TO THE STORE QUESTIONS PROBLEMS MISSING PARTS For FAQ Manuals Videos Or spare Parts Please Visit bestwaycorp com support V i s i t w w w bestwaycorp com suppo r t f o r h e l p 2 ...

Page 3: ...ccess by children To avoid accidents ensure that children cannot use this spa unless they are supervised at all times DANGER Risk of Injury The suction fittings in this spa are sized to match the specific water flow created by the pump Should the need arise to replace the suction fittings or the pump be sure that the flow rates are compatible Never operate spa if the suction fittings are broken or...

Page 4: ...ld system isn t working alarms will pop up on the spa Be sure to check the status of your spa if the outdoor temperature is below 42 8 F 6 C In case of a long term absence from home when there is a risk of temperatures falling below 42 8 F 6 C we strongly suggest disassembling the spa and storing it following the storage procedure CAUTION Do not use the spa alone CAUTION Always enter and exit the ...

Page 5: ...g label must be posted near your spa in a readable position during using your spa 1 Take out the warning label from the accessory kit 2 Carefully peel the warning label 3 Affix the warning label To order the warning label please contact your local Bestway After Sales Service ASSEMBLY THE PROVIDED WARNING LABEL WARNING REDUCE THE RISK OF ELECTROCUTION 1 NEVER PLACE AN ELECTRIC APPLIANCE WITHIN 5 FE...

Page 6: ...ation instructions shall void the SOFA certification No modification shall be made to a SOFA structure or flow path unless the new configuration has been certified as new SOFA Cover grates and all other SOFA components shall be replaced at or before the end of their service life and that service life begins the month and year in which a SOFA component is installed with or without water 5 Winterizi...

Page 7: ...door Installation Be aware of special requirements if you install the spa indoors Humidity is a natural side effect with SaluSpa installation First determine the effects of moisture on exposed wood paper etc in the proposed location To minimize these effects it is best to provide plenty of ventilation to the selected area An architect can help determine if more ventilation is needed 2 Outdoor Inst...

Page 8: ...ended to purchase For reference please use the diagrams below MIAMI AIRJET S100105 60002 71 x 26 1 80 m x 66 cm 2 04 54123GASS17 1 09 F4C009B 02ASS17 1 15 P05346 1 06 P05343 1 11 P05320 6 03 P05160 1 14 P61727ASS18 1 01 P05135 1 07 P05345 1 12 2 02 P05332 US P05333 NA 1 08 P05524 2 13 P61726ASS18 1 05 P6931ASS16 1 10 P00217 1 16 P6609ASS16 1 2 4 2 3ºF h 1 1 5ºC h 320 gal h 1 211 L h 0 055Bar 0 8PS...

Page 9: ... 13 P61726ASS18 1 05 P6931ASS16 1 10 P00217 1 16 P6609ASS16 1 2 2 4 2 3ºF h 1 1 5ºC h 320 gal h 1 211 L h 0 055Bar 0 8PSI 177 gal 669 L 1 534 Lb 696 kg 04 54123GASS17 1 09 F4C009B 02ASS17 1 15 P05346 1 06 P05343 1 11 P05320 6 03 P05162 1 14 P61727ASS18 1 01 P05138 1 07 P05345 1 12 2 02 P05332 US P05333 NA 1 08 P05524 2 13 P61726ASS18 1 05 P6931ASS16 1 10 P00217 1 16 P6609ASS16 1 2 2 4 2 3ºF h 1 1 ...

Page 10: ...6609ASS16 1 2 2 4 2 3ºF h 1 1 5ºC h 320 gal h 1 211 L h 0 055Bar 0 8PSI 177 gal 669 L 1 534 Lb 696 kg 04 P04125 1 09 F4C009B 02ASS17 1 15 P05346 1 06 P05343 1 11 P05320 8 03 P05179 1 14 P61727ASS18 1 01 P05157 1 07 P05345 1 12 2 02 P05332 US P05333 NA 1 08 P05524 2 13 P61726ASS18 1 05 P6931ASS16 1 10 P00217 1 16 P6609ASS16 1 4 6 2 3ºF h 1 1 5ºC h 320 gal h 1 211 L h 0 055Bar 0 8PSI 205 gal 778 L 1...

Page 11: ...1 2PSI 222 gal 840 L 1 938 Lb 879 kg 04 54174GASS18 1 09 P00217 1 15 P6609ASS16 1 16 P05767 1 06 P05343 1 11 2 03 P05195 1 14 P05346 1 01 P05191 1 07 P05345 1 12 P61726ASS18 1 02 P05332 US P05333 NA 1 08 P05524 2 13 P61727ASS18 1 05 P05341 1 10 P05320 6 2 4 6 2 3ºF h 1 1 5ºC h 320 gal h 1 211 L h 0 08Bar 1 2PSI 242 gal 916 L 2 103 Lb 954 kg HONOLULU AIRJET S100105 60020 77 x 28 1 96 m x 71 cm HAWA...

Page 12: ... 69Bar 7 10PSI 297 gal 1123 L 2 548 Lb 1155 kg 04 54175GASS18 1 09 P00217 1 15 P6609ASS16 1 16 P05767 1 06 P05343 1 11 2 03 P05201 1 14 P05346 1 01 P05197 1 07 P05345 1 12 P61726ASS18 1 02 P05332 US P05333 NA 1 08 P05524 2 13 P61727ASS18 1 05 P05341 1 10 P05320 8 2 5 7 1 2ºF h 0 5 1ºC h 320 gal h 1 211 L h 0 08Bar 1 2PSI 314 gal 1190 L 2 668 Lb 1210 kg ST MORITZ AIRJET S100105 60024 85 x 28 2 16 m...

Page 13: ...1 15 P05346 1 06 P05343 1 11 P05320 6 03 P05662 1 14 P61727ASS18 1 01 P05661 1 07 P05345 1 12 2 02 P05332 US P05333 NA 1 08 P05524 2 13 P61726ASS18 1 05 P6931ASS16 1 10 P00217 1 16 P6609ASS16 1 2 2 3 2 3ºF h 1 1 5ºC h 320 gal h 1 211 L h 0 055Bar 0 8PSI 160 gal 605 L 1 389 Lb 630 kg 13 ...

Page 14: ...sition connect the spa heater and fill with water Important The water temperature used to fill the spa must be above 42 8 F 6 C otherwise when you begin to operate with the spa heater the E03 alarm will appear Important If the Freeze Shield system isn t working alarms will pop up on the spa Be sure to check the status of your spa if the outdoor temperature is below 42 8 F 6 C In case of a long ter...

Page 15: ...5 6 2 2 4 HELSINKI 5 min 0 48 0 69Bar 7 10PSI 5 min 7 8 9 10 15 ...

Page 16: ...ket is damaged If you are unsure about the quality of the electrical supply please consult a qualified electrician before use NOTE When inflating you will notice that air will be expelled from the area where the air hose connects to the pump this is normal for technique requirements NOTE Do not use an air compressor to inflate the pool NOTE Do not drag the pool on rough ground as this may cause da...

Page 17: ...here is not an air leak If the air valve is loose use the provided wrench to fasten the air valve following these steps With one hand hold the backside of the air valve from the inner side of the spa wall and turn the wrench clockwise NOTE 1 Do not over tighten 2 Do not adjust the air valve connector when the spa is in use 17 ...

Page 18: ...ent amount of time with the heater ON may be set from 1 to 999 hours Reservation time adjustment the number of hours FROM NOW when the heater will begin to function may be set from 0 to 999 hours If the timer is set at 0 hour the heating system will activate immediately Note that the timer is one time per use the user sets the duration of the heating cycle and how many hours from now the heating c...

Page 19: ...Timer function is set D MASSAGE SYSTEM BUTTON Use this button to activate the massage system which has a 30 minute auto shutoff feature The light above the Massage System Button displays red when activated IMPORTANT Do not run the Massage system when the cover is attached Air can accumulate inside the spa and cause irreparable damage to the cover and bodily harm NOTE Heat and massage system work t...

Page 20: ...ower than 42 8 F 6ºC WINTER USE INSTRUCTIONS You can keep the spa on during winter when the temperature is lower than 42 8 F 6 C The Freeze Shield system automatically keeps the water temperature between 42 8 F 6 C and 50 F 10 C and it will prevent the water from freezing Important If the water temperature is below 42 8 F 6 C the spa heater must always be on In this mode the Freeze Shield system c...

Page 21: ...ses to prevent water from escaping then disconnect the pump screw on the cap P00217 to avoid water coming out from the air pipe P00217 C o n l o i n 5 Filter Set Filter Cartridge Water Maintenance Many pollutants in the water settle on surfaces below the water line These pollutants can cause bacterial algal or fungal growth It is recommended that spas are cleaned as regularly as necessary After a ...

Page 22: ...ant Over usage of chemical will discolored the printing and all points of the spa material in worse case damage the structure of the spa liner pH 7 4 7 6 Total Alkalinity 80 120ppm Free Chlorine 2 4ppm Using chemical tablets not included Using chemical liquid not included Water quality will be directly related to frequency of use number of users and overall maintenance of the spa The water should ...

Page 23: ...E Dry the spa pool DISASSEMBLY AND STORAGE P00217 NOTE Lift up the spa when there is only a little water left Damages to the handles are not covered under the warranty NOTE Dry the spa pool 2 3 4 6 1 5 8 Only for Drop stitch Spa 23 ...

Page 24: ...tore REPAIR For PVC part If the spa is torn or punctured use the provided underwater adhesive repair patch 1 Clean area to be repaired 2 Carefully peel patch 3 Press patch over area to be repaired 4 Wait 30 seconds before inflation For Tritech PVC material If the spa is torn or punctured use the provided PVC repair patch and glue not included following these steps 1 Clean and dry area to be repair...

Page 25: ...placement section Refer to the chemical manufacturer s instructions To unlock the control panel press the button for 3 seconds If the control panel will not unlock restart the pump unplug and plug in the pump Press the on off button for 2 seconds If the problem persists for assistance please visit the support section on our website www bestwaycorp com For assistance please visit the support sectio...

Page 26: ...he spa and place a garden hose inside the pipes to wash the debris To be sure all debris is removed perform the operation from the outside and inside of the spa Use a toothbrush to remove any stubborn debris For assistance please visit the support section on our website www bestwaycorp com 7 Check the washers inside the coupling for damage Unscrew the couplings and remove the washer for further in...

Page 27: ...27 ...

Page 28: ... Union vertreten von Prodotto distribuito e rappresentato nell Unione Europea da Bestway Europe S r l Via Resistenza 5 20098 San Giuliano Milanese Milano Italy Distributed in North America by Distribués en Amérique du Nord par Distribuido en Norteamérica por Bestway USA Inc 3411 E Harbour Drive Phoenix Arizona 85034 United States of America Tel 86 21 69135588 For U S and Canada Distributed in Lati...