WARNING
IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS.
WARNING –
To reduce the risk of injury, do not permit children to use this
product unless they are closely supervised at all times.
A wire connector is provided on this unit to connect a minimum 8 AWG (8.37 mm
2
)
solid copper conductor between this unit and any metal equipment, metal enclosures
of electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit.
DANGER –
Risk of injury.
a) Replace damaged cord immediately.
b) Do not bury cord.
c) Connect to a grounded, grounding type receptacle only.
WARNING –
This product is provided with a ground-fault circuit-interrupter
integrated with the power plug at the end of the cord. The GFCI
must be tested before each use. With the product operating, push the test button on
the GFCI and the product should not operate. Push the reset button on the GFCI and
the product should now operate normally. When the product fails to operate in this
manner, there is a ground current flowing indicating the possibility of an electrical
shock. Disconnect the power until the fault has been identified and corrected.
DANGER –
Risk of Accidental Drowning. Extreme caution must be exercised to
prevent unauthorized access by children. To avoid accidents, ensure
that children cannot use this spa unless they are supervised at all times.
DANGER –
Risk of Injury. The suction fittings in this spa are sized to match the
specific water flow created by the pump. Should the need arise to
replace the suction fittings or the pump, be sure that the flow rates are compatible.
Never operate spa if the suction fittings are broken or missing. Never replace a
suction fitting with one rated less than the flow rate marked on the original suction
fitting.
DANGER –
Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal
surfaces. As an alternative, a spa may be installed within 5 feet of
metal surfaces if each metal surface is permanently connected by a minimum 8 AWG
(8.37 mm
2
) solid copper conductor to the wire connector on the terminal box that is
provided for this purpose.
DANGER –
Risk of Electric Shock. Do not permit any electric appliance, such as a
light, telephone, radio, or television, within 5 feet (1.5 m) of a spa.
WARNING –
To reduce the risk of injury:
a) The water in a spa should never exceed 104°F (40°C). Water temperatures
between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult.
Lower water temperatures are recommended for young children and when spa use
exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal
damage during the early months of pregnancy, pregnant or possibly pregnant
women should limit spa water temperatures to100°F (38°C).
c) Before entering a spa, the user should measure the water temperature with an
accurate thermometer since the tolerance of water temperature-regulating devices
varies.
d) The use of alcohol, drugs, or medication before or during spa use may lead to
unconsciousness with the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood
pressure, circulatory system problems, or diabetes should consult a physician
before using a spa.
f ) Persons using medication should consult a physician before using a spa since
some medication may induce drowsiness while other medication may affect heart
rate, blood pressure, and circulation.
WARNING:
TO AVOID ELECTRIC SHOCK, DO NOT USE THE SPA WHEN IT IS
RAINING.
WARNING:
Water attracts children; Always attach a spa cover after each use.
WARNING:
TO REDUCE THE RISK OF INJURY: Never add water that is higher
than 104°F (40°C) into the Spa.
CONSULT YOUR PHYSICIAN FOR
RECOMMENDATIONS.
CAUTION:
We strongly recommend not to unfold and inflate the spa if the ambient temperature
is below 59°F(15°C). We suggest inflating the spa indoors, and then continuing set
up outdoors. If the outdoor temperature is lower than 42.8°F(6°C), the spa heater
must always be on. In this mode, the Freeze Shield™ system can keep the internal
temperature between 42.8°F(6°C) and 50°F(10°C) to prevent damage, such as water
freezing in the pipes or the circulation system.
IMPORTANT:
If the Freeze Shield™ system isn’t working, alarms will pop up on
the spa. Be sure to check the status of your spa if the outdoor
temperature is below 42.8°F(6°C). In case of a long-term absence from home when
there is a risk of temperatures falling below 42.8°F(6°C), we strongly suggest
disassembling the spa and storing it following the storage procedure.
CAUTION:
Do not use the spa alone.
CAUTION:
Always enter and exit the spa slowly and cautiously. Wet surfaces are
slippery.
CAUTION:
To avoid damage to the pump, the spa must never be operated unless
the spa is filled with water.
CAUTION:
Immediately leave spa if the user feels uncomfortable or sleepy.
NOTE:
Please examine equipment before use. Notify Bestway
®
at the customer
service address listed on this manual for any damaged or missing parts at
the time of purchase. Verify that the equipment components represent the model that
you had intended to purchase.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
Any changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
4
Summary of Contents for SaluSpa