3. Press
F3
to select the source to CH1 (or CH2), and only select the open channel.
4. Press
F4
to save the current waveform to the specified location..
Measurement
Scale measurement
Graticule:
This method allows you to make a quick, visual estimate and take a simple
measurement through the graticule divisions and the scale factor.
For example, you can take simple measurements by counting the major and minor
graticule divisions involved and multiplying by the scale factor. If you counted 6 major
vertical graticule divisions between the minimum and maximum values of a waveform and
knew you had a scale factor of 50mV/division, you could easily calculate your peak-to-peak
voltage as follows:
6 divisions x 50mV/division = 300mV.
Cursor measurement
The cursor measurement has two parallel lines on the screen, and move two lines to
measure the time and voltage parameters of the input signal. The result of cursor
measurement will be displayed on the second page of the cursor menu. Before use
cursor measurement, make sure that the measured source is the signal you need to
measure.
Press
Menu
button to enter, and select
Cursor
to enter cursor measurement.
Cursor Measurement Menu Table
Menu
Setting Description
Enable
On
Off
Open the cursor measurement.
Close the cursor measurement.
Type
Voltage
Time
The horizontal line is shown to measure the voltage
parameters.
The vertical line is shown to measure the time
parameters.
Source
CH1
CH2
Select the measured source.
Cursor1
Select Cursor1 and press up, down, left and right keys
to move the Cursor1 position, and display the Cursor1
value.
Cursor2
Select Cursor2 and press up, down, left and right keys
to move the Cursor2 position, and display the Cursor2
value.
Increment
The difference between the Cursor1 and the Cursor2.
To do cursor measurement, follow these steps:
1. Press
F1
to open the cursor measurement;
65
Summary of Contents for 1760DGT/2
Page 1: ...1760DGT 2 Multimetro digitale con oscilloscopio Manuale d uso 1 ...
Page 44: ...1760DGT 2 Digital multimeter with oscilloscope User Manual 44 ...
Page 75: ...8 Connect Gen Out connector to oscilloscope for observation 75 ...
Page 85: ...1760DGT 2 Multimètre numérique avec oscilloscope Manuel de l Utilisateur 85 ...
Page 117: ...8 Connectez le connecteur Gen Out à l oscilloscope pour l observation 117 ...
Page 127: ...1760DGT 2 Digitalmultimeter mit Oszilloskop Benutzerhandbuch 127 ...
Page 159: ...8 Schließen Sie den Gen Out Stecker zur Beobachtung an das Oszilloskop an 159 ...
Page 169: ...1760DGT 2 Multímetro digital con osciloscopio Manual de usuario 169 ...
Page 200: ...8 Conecte el conector Gen Out al osciloscopio para observación 200 ...
Page 210: ...1760DGT 2 Multímetro digital com osciloscópio Manual do usuário 210 ...
Page 241: ...8 Conecte o conector Gen Out ao osciloscópio para observação 241 ...
Page 251: ...1760DGT 2 Digitale multimeter met oscilloscoop Handleiding 251 ...
Page 282: ...8 Sluit de Gen Out connector aan op de oscilloscoop voor observatie 282 ...
Page 292: ...1760DGT 2 Multimetr cyfrowy z oscyloskopem Instrukcja obsługi 292 ...
Page 323: ...8 Podłączyć złącze Gen Out do oscyloskopu w celu obserwacji 323 ...
Page 333: ...1760DGT 2 Digitális multiméter oszcilloszkóppal Használati utasítás 333 ...
Page 365: ...8 Csatlakoztassa a Gen Out csatlakozót az oszcilloszkóppal megfigyelés céljából 365 ...