2. Press
F2
to select a type of cursor measurement.
3. Press
F3
to select the channel that needs to be measured.
4. Press
F4
to enter the second page, press F1 or F2 to select Cursor1 or Cursor2,
press up, down, left and right to move Cursor1 or Cursor1;
5. The result of cursor measurement will be displayed on the cursor menu.
Automatic Measurement
The oscilloscope provides 2 kinds of automatic measurements, including frequency and
amplitude.
Press
Menu
button to enter, select
Measure
to enter automatic measurement. Press
F1
to open, the measurement results will be displayed on the top left corner of the screen.
Measurement Menu Table
Menu
Description
Frequency
Measure the frequency of the signal.
Maximum
Voltage
Measure the maximum voltage of the signal.
Minimum
Voltage
Measure the minimum voltage of the signal.
Attention:
In the measurement result, the yellow font is the result of CH1, and the green font is the
result of CH2.
Utility
Press
Menu
button to enter.
Utility Menu Table
Menu
Setting
Description
Language
中文
English
Italian
Set the menu language.
Sound
On
Off
Open the key sound.
Close the key sound.
Backlight
luminance
1~10
Set backlight brightness of the screen.
Backlight
time
30s
60s
90s
120s
Unlimited
Set the screen backlight time.
66
Summary of Contents for 1760DGT/2
Page 1: ...1760DGT 2 Multimetro digitale con oscilloscopio Manuale d uso 1 ...
Page 44: ...1760DGT 2 Digital multimeter with oscilloscope User Manual 44 ...
Page 75: ...8 Connect Gen Out connector to oscilloscope for observation 75 ...
Page 85: ...1760DGT 2 Multimètre numérique avec oscilloscope Manuel de l Utilisateur 85 ...
Page 117: ...8 Connectez le connecteur Gen Out à l oscilloscope pour l observation 117 ...
Page 127: ...1760DGT 2 Digitalmultimeter mit Oszilloskop Benutzerhandbuch 127 ...
Page 159: ...8 Schließen Sie den Gen Out Stecker zur Beobachtung an das Oszilloskop an 159 ...
Page 169: ...1760DGT 2 Multímetro digital con osciloscopio Manual de usuario 169 ...
Page 200: ...8 Conecte el conector Gen Out al osciloscopio para observación 200 ...
Page 210: ...1760DGT 2 Multímetro digital com osciloscópio Manual do usuário 210 ...
Page 241: ...8 Conecte o conector Gen Out ao osciloscópio para observação 241 ...
Page 251: ...1760DGT 2 Digitale multimeter met oscilloscoop Handleiding 251 ...
Page 282: ...8 Sluit de Gen Out connector aan op de oscilloscoop voor observatie 282 ...
Page 292: ...1760DGT 2 Multimetr cyfrowy z oscyloskopem Instrukcja obsługi 292 ...
Page 323: ...8 Podłączyć złącze Gen Out do oscyloskopu w celu obserwacji 323 ...
Page 333: ...1760DGT 2 Digitális multiméter oszcilloszkóppal Használati utasítás 333 ...
Page 365: ...8 Csatlakoztassa a Gen Out csatlakozót az oszcilloszkóppal megfigyelés céljából 365 ...