3
108
E
N
G
IN
E ASS
E
M
B
LY AN
D CO
NTRO
LS
Closing caps for finger follower support shaft seats.
Application of M4 screw to allow pulling out the
finger follower support shafts with your fingers.
Finger follower / shafts unit.
3.17.3.2
FINGER FOLLOWER/SHAFTS
UNIT
Disassemble the two caps
1
which keep the finger follo
-
wer shafts in place.
Make sure the face of the cap facing the shaft does not
have deep traces or signs of wear. If so, replace the caps.
Check the state of use of the two O-rings between the
caps and the cylinder head. We recommend they be re
-
placed.
The finger follower shafts have a threaded hole (M4) at
the end so that they can be extracted. To pull them out,
just screw a sufficiently long M4 screw
A
in this hole and
pull out. In this way, the finger followers can be extracted.
Make sure the outside diameters of the shafts
2
and
the inside diameters of the holes on the finger fol
-
lowers
3
respect the following service limits:
Shaft service limit: 6.98mm
finger follower service limit: 7.03mm
Play limit: 0.05mm
Check to see that the contact areas between the fin
-
ger followers and the calibrated discs, and between
the finger followers and the cams are not chipped
or particularly worn. If so, replace the finger follo
-
wer.
1
A
3
2