![background image](http://html1.mh-extra.com/html/betafence/r2000/r2000_installation-manual_2742826019.webp)
19
Robusta SC
4.4.
Positioning of the gate and posts on the ground
anchors:
Very important:
Position the guiding post and lock post only when resin is
completely hardened out.
The gate is positioned as a whole unit with the guiding post, the
rear guiding wheels and the lock post on their corresponding
ground anchors.
Chronological order of actions:
1)
Remove packaging from the guiding post. Don’t remove the
strap that holds the underbeam and base plate together.
2)
Bring the gate with the guiding post above the
ground anchors at ± 50 cm above the ground.
3)
Identify the cables which go to the end post
(photocells, key switch, etc.).
4)
Pull these cables through the cable pipe to the
lock post.
5)
Pass the exposed ends of the power supply and
other cables through the hole in the base plate
of the guiding post and through the hole
foreseen into the motor to the connection board.
ATTENTION!
Ensure that cables and wires are not crushed between surfaces
while lowering and positioning the gate onto the ground anchors.
6)
For release the rear guiding wheels have we two
possibilities:
Cut off the straps which fix the rear guiding
wheels to the under beam.
Unscrew the nuts that fix the Alu profile from
the both guiding wheels. Remove the profile and
fix the nuts again.
Summary of Contents for R2000
Page 1: ...1 Robusta SC Cantilever sliding gates Robusta SC Installation Manual ...
Page 11: ...11 Robusta SC 4 1 1 Automatic version right opening ...
Page 12: ...12 Robusta SC 4 1 2 Automatic version left opening ...
Page 13: ...13 Robusta SC 4 1 3 Motorizable version right opening ...
Page 14: ...14 Robusta SC 4 1 4 Motorizable version left opening ...
Page 15: ...15 Robusta SC 4 1 5 Manuel version right opening ...
Page 16: ...16 Robusta SC 4 1 6 Manuel version left opening ...