Robusta SC
8.
Set-up of the end position:
We use two different dental racks:
-
Plastic dental racks
-
Metal dental racks
For the limit switch use we the same holder with magnet for both types.
We have two possibility for this depends on the opening of the gate.
-
Left opening
-
Right opening
You must look at the gate where the engine is installed (normally the motor
is installed on the inside).
When the wing goes open right = right opening(symbol –
Ǝ
)
Will say: Opening limit switch = FC 1
Closing limit switch = FC 2
When the wing goes open left = left opening(symbol E -)
Will say: Opening limit switch = FC 2
Closing limit switch = FC 1
Do the settings with parameter d1 in basic function for doing this.
Example for a right opening:
When you open the gate in manual mode in the correctly position:
-
Fix the limit switch on the dental rack before FC1.
-
Led FC1 goes out.
When you close the gate in manual mode in the correctly position:
-
Fix the limit switch on the dental rack before FC2.
-
Led FC2 goes out.