11
Created 11.08.2014:
Approved 11.08.2014:
Bodo Kiesewalter
5.2 Used with drive unit 746/844 with firmware older then 1Q
Drive unit 746 / 844 is
not
foreseen of a label
5.2.1 Setting DIP switch
Transmitter (component on the wing):
Switch 1 on
Switch 2: off
Switch 3: off
Receiver (part of the drive unit):
Switch 1 on
Switch 2: off
Switch 3: on
Switch 4: off
Switch 5 off
5.2.2
The activation time is not programmed, a battery pack is needed!
5.2.3
Go in ‘advanced programming mode’ on motor controller and set FS on ‘Y’ (SA is not
available with this firmware version)
6. Installation of resistive safety strip at the front of the wing of
Robusta Plus sliding gate
If the AERF system doesn’t work as described in point 5.1, the light beam safety strip in front of
the wing can changed to a resistive safety edge.
6.1 Table of required resistive safety strip (SAP code) according the height of
the gate
Nominal [m]
Height of wing [mm]
SAP CODE of safety strip
1
967
1006184
1,2
1167
1006185
1,5
1467
1006186
1,7
1667
1006187
2
1967
1006186
2,4
2367
1006190