7
Created 11.08.2014:
Approved 11.08.2014:
Bodo Kiesewalter
If 2 OSE units connected in line (serial) and one of it is activated, the other one will activated
automatically.
How to solve the problem:
Take a new light beam and connect to the OSE unit. (
SAP code 1017486
)
If the LED goes off, OK, if not,
Exchange the OSE unit. (
SAP code 1017448
)
4.2 Photocells
The photocells consists of 1 transmitter and one receiver
Transmitter on the photos below
Electrical drawing page 16
With plastic cap
Without plastic cap
Red LED in “ON” status;
One OSE unit is activated or fault,
the
2
nd
one is active too.
LED activ, transmitter is
working
If the LED is off, power is off or
transmitter is fault