45
BATTERY CHECK CARD – HOUR METER
1. Verify that when turning on the machine the battery check card has the
following starting sequence:
• Turning on of the LED which correspond to the set-up (red LED = “0”).
• Turning on of all the LEDs (check of the lamps)
• Turning on of the LEDs depending on the charge of the battery
2. Verify the hour meter functionality
• To verify which is the set-up you turn on the machine and check which
is the first LED that turns on. Counting the LEDs since the left side any
LED correspond to a position and the LED which turn on correspond to
the current set-up.
• Verify that if the machine uses wet cell batteries the adjustment is on
position 1.
• Verify that if the machine uses GEL batteries the adjustment is on posi-
tion 4.
WARNING: A wrong set-up of the battery control card can
compromise the battery efficiency and damage then in ir-
reversible way.
1. Verify the cleanness and functionality of the
solution filter
under the
solution tank plug.
2. Check cleanness and sealing of the
solution filter
.
3. Confirm that solution tank is completely filled.
4. Verify the sealing of the hoses,
solenoid valve
and the
water valve
.
5. Verify that the solution, with valve completely open, falls continuously
on the floor.
WATER PLANT INSPECTIONS
1
4