23
BetterOutdoorProducts.com
Repair
Before replacing any part, ALWAYS remove battery
ground cables and insulate terminals.
Ignition Switch
Electric Start (10286)
Manual Start (10333)
1. Remove ignition key.
2. Using a 7/8” open end wrench, remove the nylon
ignition switch nut (10501).
3. Reach under dash panel and pull ignition switch out
Figure 26
.
Figure 26
4. Unplug ignition switch from wiring harness.
5. Install new switch in reverse order.
Blade Engagement Interlock Switch (10081)
1. This switch is included as a component of the blade
engagement control cable.
2. Please refer to Blade Engagement control
replacement.
Battery (10799)
All Quick Dually™ mowers are equipped with the
latest assembled glass mat maintenance free
battery.
Battery terminals or metal tools could short against
metal machine components causing sparks. Sparks
can cause the battery gasses to explode, resulting in
personal injury.
• When removing or installing the battery,
Do Not
allow the battery terminals to touch any metal parts
of the machine.
•
Do Not
allow metal tools to short between the
battery terminals and metal parts of the machine.
Incorrect battery cable routing could damage the
machine and cables causing sparks. Sparks can
cause the battery gasses to explode, resulting in
personal injury.
• Always Disconnect the negative (black) battery
cable before disconnecting the positive (red) cable.
• Always Reconnect the positive (red) battery cable
before reconnecting the negative (black) cable.
1.
Remove ignition switch key
.
2. Using a 1/2" wrench, remove the keps nut and
remove the black ground cable and insulate end of
cable
Figure 27
.
Figure 27
3. Using a 1/2” wrench, remove the keps nut from top
of starter solenoid and remove red cable
Figure 28
.
Figure 28
4. Using a 1/2” wrench and socket, remove the keps
nut holding battery clamp
Figure 29
.