background image

Quick-Start Guide

E2K-210-10-17 Rev. 2  

October 2017

Bettis TEC2 Electric Actuator with  
Model 500 Quick-Start Guide

Summary of Contents for TEC2

Page 1: ...Quick Start Guide E2K 210 10 17 Rev 2 October 2017 Bettis TEC2 Electric Actuator with Model 500 Quick Start Guide ...

Page 2: ......

Page 3: ...cs will display the mode of operation valve status position torque and alarm symbols The message center will display actuator setup options data entry feedback and alarm messages Once you follow the simple steps outlined in this guide the actuator will be ready for normal operation The bar graph position digits icons and LEDs will indicate the valve status LED Indicators Valve Torque Display Diagn...

Page 4: ...rolled setting a unique network address If full data was not provided when ordering or if changes are needed see the TEC2 Installation Operation Manual E2K 405 0117 which can be found at www emerson com bettis Power Actuator Verify the voltage rating on the unit nameplate Connect power to the unit Are Position Limits Set Does SET LIMITS BEFORE OPERATING EE and the alarm icon appear and is the yell...

Page 5: ...elease quickly 1 STOP Place the selector knob in the STOP position Then toggle the control knob in rapid succession to YES then NO then YES then NO and release The Setup icon will be displayed on the display module and SETUP will be displayed on the message center Rotate the control knob to YES The message center will display SET LIMITS BEFORE OPERATING Set position limits as described on the next...

Page 6: ...r Electrical Operation STEP 1 CLOSED Valve Position 2 3 4 YES LOCAL CLOSE Hold until desired position is reached 1 STOP Turn the selector knob to the LOCAL position At the CLOSE VALVE THEN SELECT STOP prompt hold the control knob in the CLOSE position until the desired position is reached Return the selector knob to the STOP position At the ACCEPT CLOSE LIMIT prompt select YES ...

Page 7: ...alve Position 2 3 4 YES LOCAL OPEN Hold until desired position is reached 1 STOP Turn the selector knob to the LOCAL position At the OPEN VALVE THEN SELECT STOP prompt hold the control knob in the OPEN position until the desired position is reached Return the selector knob to the STOP position At the SAVE LIMITS prompt select YES Rotate selector knob to either next or back until EXIT is displayed ...

Page 8: ...eclutch rotate toward open for 1 turn Turn the selector knob to the LOCAL position At the CLOSE VALVE THEN SELECT STOP prompt depress the declutch lever while rotating the handwheel until the clutch is fully engaged Release the lever When the valve is fully closed move the valve in the open direction for one handwheel turn to allow for coasting of the motor Return the selector knob to the STOP pos...

Page 9: ... declutch rotate toward open for 1 turn Turn the selector knob to the LOCAL position At the OPEN VALVE THEN SELECT STOP prompt depress the declutch lever while rotating the handwheel until the clutch is fully engaged Release the lever When the valve is fully opened move the valve in the close direction for one handwheel turn to allow for coasting of the motor Return the selector knob to the STOP p...

Page 10: ...n LED stays ON and 0 is displayed 1 When turning to close green LED blinks 2 When fully closed green LED remains lit Valve Open As you operate the valve in the open direction verify that the red LED is blinking When fully open is reached verify that the red LED stays ON and 100 is displayed 1 When turning to open red LED blinks 2 When fully open red LED remains lit Note It is also configurable to ...

Page 11: ...S NO Release quickly 1 STOP Turn the selector knob to the STOP position then toggle the control knob in rapid succession to YES then NO then YES then NO and release The setup icon will be displayed on the display module and SETUP will be displayed on the message center Rotate the control knob to YES The message center will display CHANGE DISPLAY SETTINGS ...

Page 12: ...anging the Valve Settings Changing the Valve Settings 4 5 YES NO Until appears Answer NO to the Setup prompts until CHANGE SETTINGS appears Answer YES ACCEPT PASSCODE CHARACTER 1 X appears The factory default passcode is 000 Do not change the password without recording the new password ...

Page 13: ...ing the Valve Settings Enter Passcode 6 7 YES NO If passcode character is correct to advance to correct character OR Use the control knob and answer YES if the passcode character is correct If not use NO to advance incrementally to the correct character Repeat this process until three passcode characters are entered ...

Page 14: ...210 10 17 Rev 2 October 2017 12 Changing the Valve Settings Changing the Valve Settings Changing the Valve Settings Setting Limits 8 9 YES NO Advance to the SET VALVE TRAVEL LIMITS prompt and answer YES Proceed to set limits ...

Page 15: ...correct address YES In the SETUP mode advance to NETWORK SETUP using the selector knob in the REMOTE position Answer YES Hold the control knob in the NO position until the correct address appears Answer YES Unit is now network controlled If other configuration changes are needed please see the TEC2 Installation Operation Manual E2K 405 0117 which can be found at www emerson com bettis ...

Page 16: ...uick Start Guide E2K 210 10 17 Rev 2 October 2017 14 Saving the Changes Saving the Changes Saving the Changes 1 2 YES NO SAVE CHANGES Advance to the SAVE CHANGES prompt and answer YES to save the changes ...

Page 17: ......

Page 18: ... 966 3 340 8650 F 966 3 340 8790 24 Angus Crescent Longmeadow Business Estate East P O Box 6908 Greenstone 1616 Modderfontein Extension 5 South Africa T 27 11 451 3700 F 27 11 451 3800 EUROPE Berenyi u 72 100 Videoton Industry Park Building 230 Székesfehérvár 8000 Hungary T 36 22 53 0950 F 36 22 54 3700 www emerson com bettis 2017 Emerson All rights reserved The Emerson logo is a trademark and ser...

Reviews: