Fire damper BSK9

EI90

200924.0001_ENG / Sept. 2021   teamfr

ont.se

Sound data

The speed is calculated on the damper’s gross area, i.e.  
one BSK9 - 400 x 400 has a gross area of 0.16 m

2

.

The specified pressure drop applies to the damper without accessories.

Correction of sound power level, L

Wok

, in octave band

L

Wok

 = L

W

 + K

ok

Correction, K

ok

75

Total pr

essur

e dr

op, Pa

Air speed, m/s

Sound power level

Technical data

1  Damper height < 400 mm

2  Damper height H ≥ 400 mm

Correction of sound power level, L

W

, for different  

sizes use curves  1  -  2  according to: 

L

W

 = L

Wt

 + K

1

Damper height

mm

Damper area, m

2

< 400 acc. to  1

-

0,08

0,16

0,28

-

≥ 400 acc. to  2

0,08

0,16

0,32

0,64

1,28

K

1

-3

0

3

6

9

Opening 

angle

Centre frequency Hz

63

125

250

500 1000 2000 4000 8000

90°

-1

-11

-18

-23

-26

-28

-32

-38

Tol. ± dB

1

2

3

4

6

6

6

6

Reviews: