background image

IMPORTANT

INFORMATION

FOR

 BZ13 SERIES

   

This cooler has passed the

QUALITY CONTROL INSPECTION

and meets the high standards at Beverage-Air.

This inspection includes complete refrigeration

system, cabinet construction & finish

.

IMPORTANT

PLEASE RETAIN FOR YOUR RECORDS

SALES OFFICE: P.O. BOX 5932 SPARTANBURG, S.C. 29304-5932

PHONE: (864) 582-8111 TOLL FREE 1-800-845-9800

TECHNICAL SERVICE: 1-800-684-1199, PARTS ORDER FAX: 1-800-262-9381

PLANTS: SPARTANBURG, S.C. BROOKVILLE, PA. HONEA PATH, S.C.

809-062A
rev B

Summary of Contents for BZ13 Series

Page 1: ...nspection includes complete refrigeration system cabinet construction finish IMPORTANT PLEASE RETAIN FOR YOUR RECORDS SALES OFFICE P O BOX 5932 SPARTANBURG S C 29304 5932 PHONE 864 582 8111 TOLL FREE 1 800 845 9800 TECHNICAL SERVICE 1 800 684 1199 PARTS ORDER FAX 1 800 262 9381 PLANTS SPARTANBURG S C BROOKVILLE PA HONEA PATH S C 809 062A rev B ...

Page 2: ...ly adjustable to suit package size and presentation requirements Interior cooling airflow performance should be considered when establishing shelf to product spacing An equal spacing of shelves with no less than 1 2 54 cm between top surface of product and bottom surface of shelf top is recommended To ensure proper airflow product must not extend beyond the front or rear edge of the shelving and m...

Page 3: ... maintain acceptable compressor operating temperature and efficient refrigeration system operation the condenser must be cleaned periodically Cleaning intervals will vary according to cabinet proximity to customer traffic location cleanliness humidity etc After initial unit placement it is recommended that the condenser face be inspected for blockage every other month until the need for cleaning i...

Page 4: ......

Page 5: ...cation mark cannot be seen Physically verify that the lamp has been rotated and locked into place See pictures below Caution Improperly installed lamps may cause damage to the lighting circuit Beverage Air shall have no liability whatsoever for equipment or component failures or other damages or losses which arise as a result of improper installation Bi pin lamp end identification mark Pins may no...

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ...l setting 1 Loose parts or mountings 2 Tubing rattle 3 Bent fan blade causing vibration 4 Fan motor bearings worn SOLUTION 1 Plug in line cord 2 Replace fuse 3 Refer to electrical section 4 Repair or replace control 5 Check wiring against diagram 1 Check wiring against diagram 2 Determine reason and correct 3 Determine reason and replace 4 Determine reason and correct replace if necessary 1 Determ...

Page 10: ...ince most field type vacuum pumps cannot pull a low enough vacuum to remove moisture from the system it is recommended that the system be triple evacuated breaking each time with dry refrigerant nitrogen Use care to purge air from the charging hose when breaking the vacuum 왎 CHARGING REFRIGERATION SYSTEM Since capillary tube systems have small critical refrigerant charges we recommend that a field...

Page 11: ...SERVICE RECORD ...