Summary of Contents for RI Series

Page 1: ...RATING INSTRUCTIONS for all Hydrocarbon RI Refrigerator Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web beverage air com 809 215A 06 03 2020 SEE BACK COVER FOR WARRANTY REGISTRATION ...

Page 2: ... information is located with this manual Please complete the card and submit it to Beverage Air within TEN days of installation Failure to properly register equipment may limit or void the warranty Beverage Air reserves the right to change specifications and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for pre...

Page 3: ...ngers There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other flammable material near the cabinet Do ALWAYS Use a Beverage Air recommended technician certified to repair R290 equipment Use ONLY Beverage Air factory service parts Use of non OEM parts can be danger...

Page 4: ... is necessary to move the Refrigerator after removal from the skid remove all doors and carefully push the unit at a point of no more than 36 from the bottom to avoid damage CAUTION SAFETY Push ONLY below the 36 inch 91 meter height Location will vary by model Do NOT push in this area ...

Page 5: ...t substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected to excessive cold May only be connected to a dedicated electrical circuit Extension cords are not permitted Minimum Maximum Voltage 104 127 Room Air Temp 60º F 100º F Air Flow All Models regardles of section door count or door materi...

Page 6: ... 5 5 RI18HC G 27 1 4 x 29 1 8 x 72 3 8 Full Glass 5 5 RI18HC HG 27 1 4 x 29 1 8 x 72 3 8 Half Glass 5 5 RI18HC HGS 27 1 4 x 29 1 4 x 72 3 8 Half 1 Solid 1 Glass 5 5 Height includes casters PRODUCT INFORMATION All models will maintain product temperature between 35 5 and 40 5 degrees F at the factory setting of 38 0 F All models are 115 volts 60 Hz AC ALWAYS REFERENCE YOUR EQUIPMENT DATA PLATE AMPS...

Page 7: ...Rear 3 Below Floor Load The floor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maximum product load Ventilation Grille area at front must be free and clear of any object or wall Power Outlet Dedicated power outlet is located within the length of the unit s power cord 0 AT TOP 3 AT REAR 0 AT SIDES ...

Page 8: ...in one direction approximately 8 and block it securely with pieces of 2x4 lumber or other suitable material 4 Thread the stem casters or legs into the 13 holes in the bottom of the cabinet Tighten by hand as much as possible Some models may already have levelers installed If so then the levelers will need to first be removed and discarded 5 Once the caster or leg cannot be turned any further use a...

Page 9: ...ips 5 Install shelves onto clips with the product retention bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf as shown 7 Confirm that the shelf is resting on ALL 4 clips and that the clips are securely attached to the pilasters 8 Improper shelf clip installation could cause the shelf and or the product on it ...

Page 10: ...rature has been set at the factory and should not need adjustment however if it was changed the standard setting is 38º F Cautions Care must be taken whenever moving or servicing the unit The refrigerant is contained in a sealed system but if released it may be flammable Door Reversal Instructions 1 Remove hinge cover 2 Remove door from the unit including the hinge mounting brackets 3 Remove white...

Page 11: ...g or defrost button for a manual defrost Note Holding the defrost button in too long will shut the controller off The internal fan will be on whenever the unit is plugged into a power supply The only time the internal fan will stop is when the unit has been disconnected from a power supply The compressor and condenser fan motor will only be on when the controller senses an increase in internal cab...

Page 12: ...off when the Compressor is not running The Condenser Fan is wired directly to the Compressor not through the controller EVAPORATOR FAN The Evaporator Fan runs continuously in refrigerators When the unit is plugged in the Evaporator Fan will run The Evaporator Fan is connected directly to incoming power not through the controller The Evaporator Fan runs continuously When the unit is plugged in The ...

Page 13: ...et Point Long press and release Increases display brightness DOWN Quick press and release Decreases Set Point Long press and release Decreases display brightness DEFROST ESC Quick press and release Activates manual defrost Long press and release Controller enter stand by mode SET ENTER Quick press and release Toggles lights on off Long press and release Toggles display F C NOTE When switched on th...

Page 14: ...User Manual for RI Refrigerators Beverage Air Rev 05 20 Beverage Air 14 Control Panel Connections Changing the Set point ...

Page 15: ...ut in alarm relay beep the buzzer Condenser alarm dor Door open for more than Always Blink dor If configured cut in alarm relay beep the buzzer Door open alarm uHi Line voltage is higher than Cop uHi Always Blink uHi If configu red cut in alarm relay beep the buzzer High voltage alarm uLi Line voltage is higher than Cop uLi Always Blink ulo If configured cut in alarm relay beep the buzzer Low volt...

Page 16: ...inse with clean water 3 Dry with a soft cloth 4 Polish with a soft cloth wiping with the grain 5 Wipe weekly with stainless steel cleaner Weekly Interior Cleaning 1 Remove all food food related items and shelves Store the food at a safe temperature 2 Disconnect power to the unit unplug it or switch the breaker off 3 Remove all loose food particles from the inside walls floor door liner and ceiling...

Page 17: ...void damaging the fins Use care to not disturb the wires connected to the controller Note If the coil is greasy the coil will need to be cleaned with coil cleaner and that should be left to an experienced technician 5 Return panel to unit 6 To reinstall the front panel line up the keeper screws behind the panel and firmly pull downwards 7 Reinstall the Phillips head screw Note Air filters are not ...

Page 18: ...small amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Discolorations Industrial Atmospheric Stains Wyandotte Bab O or Zud Rub with a dry cloth Rub with a dry cloth or stain less steel wool Apply with damp sponge or cloth Rub with a damp cloth Burnt On Foods...

Page 19: ...temp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No cooling compressor starts but shuts off Compressor start relay failure Compressor start capacitor failure Replace relay Replace capacitor No cooling compressor cycles on and off Overheating weak over...

Page 20: ...n an area free from flame or spark It must also be in a well ventilated area with a nearby open window or door A sign noting service of a system containing propane must be attached to the unit during refrigeration service A combustible gas leak detector must be used to inform anyone in the area when propane is present in the air Other Information Evacuation It is critical that a refrigeration syst...

Page 21: ... CONTROLLER DETAIL SEE CONTROLLER DETAIL WHITE BLACK BLACK WHITE COMPRESSOR DETAIL 115V 1PH COMP CONDENSER FAN C OL R S S CURRENT RELAY 1 M SEE CONTROLLER DETAIL POWER SUPPLY LAMP L E D LAMP LAMP SIGN FRAME LAMP BALLAST RED BLUE BLUE WHITE FLUORESCENT LAMP NOT ALL MODELS 2 1 2 2 3 4 CNTRL SOLID DOOR MODELS ONLY DIGITAL INPUT SIGNAL ...

Page 22: ...RAGE AIR Also this extended compressor part only warranty does NOT apply to any electrical controls condenser evaporator fan motors overload switch starting relay capacitors temperature control filter drier accumulator refrigeration tubing wiring harness labor charges or supplies which are covered by the warranty above Normal wear type parts such as light bulbs lamps and gaskets are not covered by...

Page 23: ... AND WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF This warranty shall not be assignable and shall be honored only in so far as the original purchaser This warranty does not apply outside the limits of the United States of America and Canada nor does it apply to any part th...

Page 24: ...______________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name ____________________________________________________ Business Street ____________________________________________________ Business City ____________________________________ State _________ Postal Code ___________ Mail to Beverage Air 3779 Champ...