18
4.6.4.3 FDA
Two time durations will be stored and printed for each enabled food
probe. The first will be the time taken to pull down from parameter
‘FDA1H’
to
‘FDA1L’
, and the second is the time taken to pull down
from
‘FDA2H’
to
‘FDA2L’
.
If a blast cycle terminates without reaching the temperature limits,
the duration is not stored and is replaced by ‘??’ when the
information is printed.
Use the
‘+’
(2) and
‘-’
(1) buttons to scroll through the
available selections.
4.6.5 Enabling / Disabling Auto. Print After A Blast
Cycle (Parameter ‘PrintBlast’)
It is possible to enable / disable the auto print after a blast
cycle by scrolling to the
‘Print blast’
parameter by using the
‘
‘ (2) and ‘
‘ (1) buttons and pressing the
‘Set’
(4)
button to edit the selection (as shown below).
The auto print after a blast cycle mode can be selected as
follows:
- Yes
A ticket will be printed automatically after a blast
cycle or when a probe achieves its temperature
setpoint.
- No
A ticket will not be printed automatically after a blast
cycle or when a probe achieves its temperature
setpoint.
4.6.6 Setting the Number of Hours of Data to be Stored
(Parameter ‘Store cycle’)
The number of hours worth of data to be stored can be
altered by adjusting parameter
‘Store cycle’
. Scroll to the
the
‘Store cycle’
parameter by using the ‘
‘ (2) and ‘
‘
(1) buttons and pressing the
‘Set’
(4) button to edit the
selection (as shown in the diagram below).
The number of hours worth of stored data to be retained can
be adjusted between 1 and 168. Use the
‘+’
(2) and
‘-’
(1)
buttons to increase and decrease the value.
4.6.7 First Temperature Setpoint Used in French Blast
Chill Mode (Parameter ‘ChillHigh’)
See section 4.6.5. The parameter can be set between 20
and 212.
4.6.8 Second Temperature Setpoint Used in French
Blast Chill Mode (Parameter ‘ChillLow’)
See section 4.6.5. The parameter can be set between -20
and 70.
4.6.9 First Temperature Setpoint Used in French Blast
Freeze Mode (Parameter ‘FreezeHigh’)
See section 4.6.5. The parameter can be set between 0 and
212.
4.6.10 Second Temperature Setpoint Used in French
Blast Freeze Mode (Parameter ‘FreezeLow’)
See section 4.6.5. The parameter can be set between -40
and 30.
4.6.11 First Temperature Threshold Value 1 Used in
FDA Blast Mode (Parameter ‘FDA1H’)
See section 4.6.5. The parameter can be set between 20
and 212.
4.6.12 Second Temperature Threshold Value 1 Used in
FDA Blast Mode (Parameter ‘FDA1L’)
See section 4.6.5. The parameter can be set between -40
and 70.
4.6.13 First Temperature Threshold Value 2 Used in
FDA Blast Mode (Parameter ‘FDA2H’)
See section 4.6.5. The parameter can be set between 20
and 212.
4.6.14 Second Temperature Threshold Value 2 Used in
FDA Blast Mode (Parameter ‘FDA2L’)
See section 4.6.5. The parameter can be set between -40
and 70.
1
2
3
4
1
2
3
4
Summary of Contents for Williams WBC110
Page 12: ...12 by OPERATING ENGINEERS MANUAL for WILLIAMS DATA LOGGER W D L with PRINTER MODULE...
Page 20: ...20 PARTS LIST FOR A WBC35...
Page 21: ...21 PARTS LIST FOR A WBC60...
Page 22: ...22 PARTS LIST FOR A WBC75...
Page 23: ...23 PARTS LIST FOR A WBC110...
Page 24: ...24 PARTS LIST FOR A WMBC175 220 350 CONTROLLER WITH POD PRINTER...
Page 25: ...25 PARTS LIST FOR A WMBC175 220 350 PANEL LAYOUT...
Page 26: ...26 PARTS LIST FOR A WMBC175 220 350 EQUIPMENT...
Page 27: ...27 PARTS LIST FOR A WMBC175 220 350 POD EQUIPMENT...
Page 28: ...28 PARTS LIST FOR A WMBC175 220 350 PANEL LAYOUT...
Page 29: ...29 PARTS LIST FOR A WMBC350 EQUIPMENT...
Page 30: ...30 PARTS LIST FOR A WMBC480 660 PANEL LAYOUT...
Page 31: ...31 PARTS LIST FOR A WMBC480 660 CONTROL PANEL WITH PRINTER POD...
Page 32: ...32 PARTS LIST FOR A WMBC480 EQUIPMENT LAYOUT...
Page 33: ...33 PARTS LIST FOR A WMBC660 EQUIPMENT LAYOUT...
Page 34: ...34 PARTS LIST FOR A WMBC480 660 POD EQUIPMENT...
Page 35: ...35 PARTS LIST FOR A WMBC480 660 PANEL LAYOUT...
Page 49: ...49...
Page 50: ...50...
Page 51: ...51...