background image

10

EXTERIOR CLEANING:

INTERIOR CLEANING:

!

!

CAUTION: Do not use steel wool or other abrasive cleaners. Do not use cleaners or sanitizers

containing lye, chlorine, iodine, ammonia or bromine as these will damage the finish on the stainless

steel.

!

!

CAUTION: Do not use steel wool or other abrasive cleaners. Do not use cleaners or sanitizers

containing lye, chlorine, iodine, ammonia or bromine as these will damage the finish on the stainless

steel.

!

!

CAUTION: Use only cleaners for stainless steel or aluminum: Fantastic, 409, Scotchbrite, dish

washing products are recommended.Follow all directions for safe use of these products.

!

!

CAUTION: Use only cleaners for stainless steel or aluminum: Fantastic, 409, Scotchbrite, dish

washing products are recommended.Follow all directions for safe use of these products.

Refer to

above when preparing and using cleaning solution.

Dip towel in cleaning solution

Wipe down exterior of unit.

pressure wash, hose-down, immerse, or spray the cabinet or any part of it. Follow with a clean

damp cloth to remove residual cleaning solution. Allow surfaces to air dry. Wipe exterior with towel and

stainless steel polish (or towel and lemon oil). Polish with a clean, soft cloth.

"CAUTIONS"

DO NOT

!!

CAUTION:

DO NOT

DO NOT

NOT

DO NOT

MOVING CABINET:

Disconnect cord set from power supply before cleaning.

use abrasives or harsh chemicals.

Open door all the way.
Remove ledge assemblies.
Remove holding or proofing unit, drip trough and air tunnel.
Clean holding or proofing unit.

spray electric heat unit with water or steam. Wipe with a damp cloth.

(Be sure electric cord is

plugged into power source.)

Wipe interior of unit with a towel and detergent solution.

pressure wash, hose-down, immerse, or spray the cabinet or any part of it. Remove

detergent residue with a clean damp towel.Allow surfaces to air dry.

Make sure door is secured before moving cabinet.
Unplug electrical cord before moving cabinet.
Empty water from proofing pan, if applicable.
Remove drip trough and pour out condensation before moving, if applicable.

!

!

!

!
!

!

!

!

!

!

Summary of Contents for Classic-Line Proofer Heater CPH70-MP17

Page 1: ...PROOFER HEATER Model Number CPH70 MP17 Innovative Foodservice Equipment Custom Designed for Performance Service and Value Phone 1 Fax 1 214 565 0976 Toll Free 1 800 441 1601 Website www BevLes com E mail sales BevLes com 214 421 7366 BevLes 729 Third Avenue Dallas TX 75226 ...

Page 2: ...al Connection 6 6 6 Control Panel Configuration 6 To Operate as a Heated Holding Cabinet 7 To Operate as a Proofing Cabinet 7 Heat and Moisture Secondary Control 8 8 Ledge Removal 8 Holding or Proofing Assembly Removal 8 Drip Trough Draining and Removal 9 Air Tunnel Removal 9 Exterior Cleaning 10 Interior Cleaning 10 Moving Cabinet 10 11 12 120V 60Hz 1 Ph 12 220 204V 50Hz 1 Ph 13 14 Domestic Warra...

Page 3: ...ich you sign as a delivery receipt All shortages must be noted on the bill of lading as the shipment is received If a bill of lading is signed as complete for the delivering truck driver there is virtually no way to secure a claim for shortages which are found later INTRODUCTION NOTE manufacturer THANK YOU for purchasing your new Classic Line Proofer Heater This unit provides the means to maintain...

Page 4: ...ETY INSTRUCTIONS WARNING can Severe injury or death occur if you ignore the message DANGER Severe injury or death will occur if you ignore the message CAUTION Minor injury or damage can occur if you ignore the message CAUTION also calls attention to safety messages in this manual NOTICE This is important installation operation or maintenance information that you should pay special attention to If ...

Page 5: ...sing or damaged safety signs Learn how to operate the equipment and how to use the controls properly Do not let anyone operate without instruction and proper training Keep your equipment in proper working condition Unauthorized modifications to the equipment may impair the functions and or safety and reduce equipment life SAFETY AND WARNING LABELS LABEL LOCATIONS ...

Page 6: ...e unit is grounded Check ground connection Do not use if unit is not grounded LOCATION Your unit should be located to provide easy access without restrictions Factory installed door opens from left to right Provisions for mounting door to open from right to left are incorporated Electrical outlet must be less than 6 ft from unit operating position Avoid enclosed or confined locations which will re...

Page 7: ...red with moisture Grease pan Place frozen buns on a bun pan 18 x 26 brush tops of buns with vegetable oil and refrigerate until dough thaws and reaches 40 F 4 6 hours or overnight One condition that is important during thawing is after the rolls are panned the tops of the rolls must not crust or dry out This can be prevented by oiling the tops of the rolls and covering them very lightly with film ...

Page 8: ...me for cool down Unplug heater cord from receptacle Carefully slide heating unit forward If in proofing mode and pan has water remaining avoid water movement to prevent spillage After unit is totally out and on a stable surface remove water pan and pour out remaining water When returning heater assembly to its operating position be sure to line up back end with bottom of louvered air tunnel If ret...

Page 9: ...mp tab upward Close by pushing front of clamp inward REMOVAL AIR TUNNEL REMOVAL The louvered air tunnel hangs on shoulder rivets through tear drop slots at back of cabinet To remove trough remove thumbscrews drop trough down and pull forward Grasp air tunnel and lift up and off ...

Page 10: ...nit pressure wash hose down immerse or spray the cabinet or any part of it Follow with a clean damp cloth to remove residual cleaning solution Allow surfaces to air dry Wipe exterior with towel and stainless steel polish or towel and lemon oil Polish with a clean soft cloth CAUTIONS DO NOT CAUTION DO NOT DO NOT NOT DO NOT MOVING CABINET Disconnect cord set from power supply before cleaning use abr...

Page 11: ...is obtained Defective thermostat Check thermostat If necessary call a licensed service agency or a licensed electrician Compartment too hot Thermostat setting is too high Turn thermostat knob to a cooler position This should be done one increment at a time until a satisfactory temperature is obtained Defective thermostat Check thermostat If necessary call a licensed service agency or a licensed el...

Page 12: ...ector Switch DP 8 Heating Thermostat 9 Digital Thermometer A Supply Cord 3 Conductor 12 A W G Type SJO Rated 105 C B 12 A W G Stranded Nickel Clad Copper 36 MILS Insulation Rated 200 C For wire numbers please refer to drawing number 475 NOTE A A A B B B B B B B B 1 2 3 4 5 6 7 8 9 Heating Proof White Black Green N Thermometer Proof Timer Ground Power Cord 120V 60Hz 1 Ph Heat 185 ...

Page 13: ...lock 5 FanMotor 6 HeatingElement 7 SelectorSwitchDP 8 HeatingThermostat 9 DigitalThermometer A Supply Cord 3 Conductor 12 A W G Type SJO Rated105 C All Other Wire Is 12 A W G Stranded Nickel Clad Copper 36 MILS Insulation Rated200 C Thermometer Temp Probe Heater Proof Heat Timer Proof T Stat Heat T Stat Fan WIRING DIAGRAM CPH70 MP17 CLASSIC LINE PROOFER HEATER 220 240V 50Hz 1Ph ...

Page 14: ... of original product occurs If at any time a claim is reported to Bevles and the purchaser is delinquent in payment for the product warranty will not apply 5 Buyer s Remedies If a Bevles product fails due to a defect in material or workmanship in conformity with the warranties in paragraph one buyer shall notify Bevles of such failure within a reasonable time but in no event beyond fifteen 15 days...

Page 15: ...plies only to equipment purchased for International use only One year and 3 months 15 months limited parts replacement only This warranty covers replacement parts only No labor travel time or travel expenses are included or implied The purchaser shall be responsible for all expenses related to travel mileage and shipping costs This warranty is in lieu of all other warranties expressed or implied a...

Page 16: ...16 Phone 1 Fax 1 214 565 0976 Toll Free 1 800 441 1601 Website www BevLes com E mail sales BevLes com 214 421 7366 BevLes 729 Third Avenue Dallas TX 75226 ...

Reviews: