Page 1: ... user before operating the appliance and retained for future reference Model No s GICC RN is only for use on Natural Gas G20 at a supply pressure of 20 mbar in G B I E Model No s GICC RP is only for use on Propane Gas G31 at a supply pressure of 37 mbar in G B I E denotes trim fret variant ...

Page 2: ... please consult document I S 813 1996 Domestic Gas Installation which is issued by the National Standards Authority of Ireland Any purpose made ventilation should be checked periodically to ensure that it is free from obstruction If the chimney or flue has been previously used by appliances burning fuels other than gas they must be swept prior to the installation of this fire If this appliance is ...

Page 3: ...ast once a year by a GAS SAFE registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for fallen debris or blockages which must be removed The chimney should also be checked to ensure clear ance of flue products After installation or during servicing a spillage test must always be carried out Rubbish of any type must N...

Page 4: ...e approximately 20 seconds c To reduce the level of heat input on the fire point the handset at the fire and press the small flame button An audible beep will be heard d To increase the level of heat input on the fire point the handset at the fire and press the large flame button An audible beep will be heard e To leave the fire in the standby mode pilot only running press the small round button o...

Page 5: ...ete see Fig 2 below d When the fire has shut down release the emergency shut off switch e The appliance will now remain in the off position until activated by the remote handset Fig 2 REPLACING THE BATTERIES REMOTE CONTROL MODELS ONLY ENSURE THE FIRE IS COOL BEFORE REPLACING BATTERIES Remove the ashpan cover The battery pack is located on the right hand side side of the burner unit at the bottom C...

Page 6: ...be cleaned with a clean damp cloth Metal polishes must not be used on these trims The trim is best cleaned by removing it from the fire and placing it face up on a flat surface The trim is easily replaced by repositioning it on the fire and pushing it back onto the magnets CLEANING THE FUEL BED We do not recommend cleaning of coals or fuelbed components as these are fragile and damage may result N...

Page 7: ...burner See fig 3 below Fig 3 b Position the two halves of the front ceramic L H R H on the locating channel in the front ceramic ensuring it is located onto the lip on the burner front ceramic support See fig 4 below Fig 4 7 NOTE The position of the fuel bed components are critical to the performance of the product Therefore please ensure that the fuel bed components are positioned as described in...

Page 8: ...the recess s in the front ceramic rail as a guide for placement See fig 5 below Fig 5 d Select four of the large coals and arrange behind the front row of coals ensuring that flame paths as indicated below are not interupted place one of the small coals at each end of the second row See fig 6 below Fig 6 8 ...

Page 9: ...the rear of the fuelbed using the ribs in the rear of the fuelbed as a guide for placement See fig 7 below Fig 7 f Select the remaining four large coals and position to fill the gaps at each end of the third row of coals as shown below in Fig 8 Fig 8 9 ...

Page 10: ...and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working on the appliance When replacing these articles we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags clearly labelled as RCF waste RCF waste is classed as a stable non reactive hazardous waste and may be ...

Page 11: ...NNECTED TO THE CORRECT POLARITY POSITVE NEGATIVE REMOVAL RE FITTING THE TRIM The trim is positioned on the firebox fixing flange and is secured with magnets USER REPLACEABLE PARTS The only user replaceable parts on this fire are the fuelbed components and coals which may be replaced as described in the above section Replacement of any other parts must be carried out by a competent person such as a...

Page 12: ...evelopment the exact accuracy of descriptions and illustrations cannot be guarantee Part No B 108170 Issue 4 BFM Europe Ltd Trentham Lakes Stoke on Trent Staffordshire ST4 4TJ Telephone General Enquiries 01782 339000 Telephone Service 0844 7700169 12 ...