2.5
GAS TIGHTNESS AND INLET PRESSURE
2.5.1
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
2.5.2
Turn on the main gas supply and carry out a gas tightness test.
2.5.3
Depress both the round buttons on the handset. The fire will then
commence its ignition sequence and will light to high. See section 3.2
for full details of the operating method for the fire.
2.5.4
Check that the gas pressure is
20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
0.4 in w.g.)
2.5.5
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
PLEASE NOTE - THE WORKING PRESSURE TEST ON THIS PRODUCT
NEEDS TO BE COMPLETED BEFORE THE FUEL-BED IS FITTED.