3.2.5.4
To turn the fan off press and hold the “SMALL” flame button until all 4
speed level bars disappear.
NOTE :
8 seconds after the light/dimmer has been set, the handset will
automatically go into manual mode. The fan starts 4 minutes after the
gas supply opens (from OFF or from pilot) at maximum speed and goes
to the displayed level after 10 seconds. The fan stops 10 minutes after
the gas is off or a pilot only (standby mode).
IT IS RECOMMENDED FOR MOST EFFICIENT PERFORMANCE OF
THE PRODUCT THE FAN MODE IS SET TO THE MAXIMUM (ALL
FOUR SPEED BARS) POSITION.
3.2.6
Low Battery Signal
3.2.6.1
When the battery in the handset needs replacing, “BATT” will be dis
played on the handset.
3.2.6.2
Remove the cover on the rear of the handset and replace the 3 off AAA
batteries as necessary.
3.2.7
To Set the Time on the Remote Handset
3.2.7.1
Simultanelously press the “UP” (large flame) arrow and “DOWN” (small
flame) arrow buttons on the remote handset.
3.2.7.2
Press the “UP” (large flame) arrow to set the hour and the “DOWN”
(small flame) arrow to set the minutes.
3.2.8
To Set the oC / 24 Hour or oF / 12 Hour Clock
3.2.8.1
Press and hold the “OFF” and the “DOWN” (small flame) arrow buttons
on the handset simultaneously until the display changes from oC to oF
and vice versa.
3.2.9
FITTING THE HANDSET WALL BRACKET / DIMMER LIGHT
BULBS
3.2.9.1
The wall bracket is supplied in the loose items pack and is optional to
fit.
3.2.9.2
If fitting the wall bracket,
please be advised that the thermostatic
sensor is contained within the handset itself, so the position of the
wall bracket will therefore be the position of temperature
measurement within the room.
To fit, position as necessary, mark
hole positions, drill and secure with fixings provided.
36