4.2.2
Remove the thermocouple retaining nut from the valve, remove the
main pipe, inlet pipe, pilot pipe and thermocouple interupter / wires from
the valve.
4.2.3
Remove the valve retaining screws and remove the valve. Re-assemble
in reverse order and carry out a gas tightness test.
4.3
Removing the Pilot Assembly.
Note : Because this appliance is fitted with an atmosphere sensing ‘Oxy-
Pilot’ it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
4.3.1
Prepare work area (lay down dust sheets etc.)
4.3.2
Remove the glass frame assembly as shown in section 2.2 and put it in
a safe location, remove burner assembly and base plate.
4.3.3
Loosen the pilot nut and remove the two screws retaining the pilot
assembly. Unscrew the thermocouple from the gas valve.
4.3.4
Re-assemble in reverse order and carry out a gas tightness test.
4.4
Replacing the Radio Frequency Receiver.
4.4.1
Prepare work area (lay down dust sheets etc.)
4.4.2
The RF receiver is located on the burner unit. Remove the RF receiver
(located in a slide in bracket), disconnect the wiring looms.
Re-assemble in reverse order.
4.4.3
Replace in reverse order and check correct operation of the appliance.
4.4.4
A new receiver will require coding to the handset, to do this, press and
hold the “reset” button until you hear 2 beeps, the 1st beep is short, the
second beep is long. After the second beep, release the reset button.
Within the next 20 seconds press the small flame button the handset
until you hear 2 additional short beeps that confirm the code is set.
Note :
The handset uses three AAA batteries and should be replaced by
removing the cover on the rear of the handset.
41