INSTALLATION MANUAL

1) GENERAL OUTLINE

The BOTTICELLI B CRC 480 D01 system is suitable for motorising sectional doors 

(fig. C), protruding fully retracting spring-operated overhead doors (fig. B) and 

counterweight overhead doors provided with  an appropriate towing arm (fig. D). 

The overhead door must not be higher than 3 metres. Its easy installation allows 

fast fitting without needing the door to be modified. The irreversible gearmotor 

keeps the door locked in the closing position.

2) TECHNICAL SPECIFICATIONS

ATTUATORE
Power supply

230V ~±10%, 50/60Hz single-phase (*)

Motor voltage

24V 

Max. power absorbed from mains 180W
Lubrication

permanent grease

Towing and pushing force

800 N

Working stroke

BINARIO L.=2900 working stroke=2400 mm (**)
BINARIO L.=3500 working stroke=3000 mm (***)

Average speed

5 m/min

Impact reaction

integrated torque limiter on control panel

Manoeuvres in 24 hours

20

Limit switch

Electronic with ENCODER

Courtesy light

24V

~

 25W max, E14 bulb

Working temperature

-15°C / +60°C

Degree of protection

IPX0

Motor head weight

5 kg

Noise level

<70dB(A)

Dimensions

see fig.1

CONTROL PANEL

Supply to accessories

24V~ (180mA max)
24Vsafe (180mA max)

Torque limiter setting

on closing and opening

Blinker connection

24V~ max 25W

Service light switching-on time

90s

Incorporated rolling-code radio 

receiver

Frequency 433.92 MHz

Coding

rolling-code algorithm

No. combinations

4 milliard

Antenna impedance

50 Ohm (RG58)

Max no. radio controls to be 

memorised

63

Fuses

see figure T

(*) Available in all mains voltages.

(**)By turning the motor head by 90° (Fig.N) the useful stroke will be 2580 mm.

(***)By turning the motor head by 90° (Fig.N) the useful stroke will be 3180 mm.

Usable transmitter versions:

All ROLLING CODE transmitters compatible with  

3) ELECTRICAL INSTALLATION SET-UP  Fig.A

Arrange for the connections of accessories and safety and control devices to 

reach the motor unit, keeping the mains voltage connections clearly separate 

from the extra low safety voltage connections (24V).

Proceed to connection following the indications given in the wiring diagram. 

The cables for connecting the accessories must be protected by a raceway (fig. 

K ref. 5C1).

4) ACTUATOR INSTALLATION

4.1) Preliminary checks

•  Check that the door is balanced.

•  Check that the door slides smoothly along its entire travel.

•  If the door has not been newly installed, check the wear condition of all its 

components.

•  Repair or replace faulty or worn parts.

•  The automation reliability and safety are directly influenced by the state of 

the door structure.

•  Before fitting the motor, remove any superfluous ropes or chains and disable 

any unnecessary appliances.

4.2) FITTING

1)    Remove the existing locking bolt from the cremone bolt of the door.

2)  Fit the metal wall bracket to the track-holder bracket using the screws sup-

plied as standard (Fig.E1). The screws must not be tightened, so that the 

bracket can be rotated. 

3)  In order for the track to be correctly fixed, mark the mid-point of the door, 

position the BIN onto the ceiling and mark the holes (Fig.F).

 

Make sure that the distance between the track and the door panel is com-

prised between 108 and 166 mm (see Fig.G). 

The table in Fig. H gives the 

various combinations for fastening the bracket to the overhead door.

4)  Drill the ceiling using a D.10 bit, with reference to the markings made previ-

ously, and insert the plugs. Fig. I.

5)   Secure the track at the base, fig.J (1-2), K (3-4-5).

6)  With the help of an adequate support, lift the entire motor, screw the screws 

onto the track-holding bracket without fixing them to the door frame (Fig.

L1) or, if the height allows it, fit the bracket  to the masonry lintel by means 

of plugs (Fig.L2).

7)  Rest  the  motor  onto  the  floor  (taking  care  not  to  damage  it)  and  fix  the 

articulated bracket to the door frame or to the ceiling.

8)  In the case where the motor is not directly fixed to the ceiling, fit the brack-

ets as shown in Fig.M, after marking and  drilling the holes with reference to 

the brackets. 

9)  In the case where the track is turned by 90° with respect to the motor head, 

use the reference template in Fig. N1 to cut out the guard, keeping to the 

measurements indicated. For track fitting to the ceiling, see Fig.F (for tracks 

fitted lower, see Fig.E).

10)  In the case where the track is made in two halves, see Fig.O; for the different 

types of fixing methods, see the previous figures.

11)  Release the carriage and fix the anchoring brackets to the door panel (Fig.H). 

The distance allowed between track and sectional door is 108 to 166 mm. 

In case of greater distance, it is necessary to use the brackets and lower the 

motor; in case of shorter distance, it is necessary to shorten the towing plate.

12)  Stick the adhesive labels supplied next to the dangerous points (Fig. Q).

5) CHAIN TIGHTENER ADJUSTMENT (BOTTICELLI B CRC 480 D01)

The operator supplied is already calibrated and inspected. Should the chain ten-

sion need to be adjusted, proceed as shown in fig. R.

WARNING: the anti-tear rubber element must never be completely com-

pressed. Scrupulously check that the rubber does not become totally com-

pressed during operation.

6) MANUAL RELEASE (See USER GUIDE  -FIG.1-).

6.1) REMPLACEMENT DE L’AMPOULE  (FIG.2) 

----------------------------------------------------------

7) TERMINAL BOARD CONNECTIONS (FIG.T)

TERMINAL DESCRIPTION

JP2

transformer wiring

JP10

motor wiring

1-2

Antenna input for integrated radio-receiver board

(1: BRAID. 2: SIGNAL)

3-4

START input (N.O.)

 

3-5

STOP input (N.C.) If not used, leave the jumper inserted.

3-6

PHOTOCELL input (N.C.) If not used, leave the jumper inserted.

3-7

FAULT input (N.O.)

Input for photocells provided with checking N.O. contact

8-9

24 V~ output for blinking light (25 W max)

10-11

24V~ 180mA max output – power supply for photocells or 

other devices.

12-13

24V~ Vsafe 180mA max output – power supply for checking 

photocell transmitters.

14-15

PARTIAL OPENING input

16-17

Ingresso APERTURA PARZIALE (N.O.)

8) SAFETY DEVICES

Note: only use receiving safety devices with free changeover contact.

8.1) TESTED DEVICES Fig. T1

8.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS Fig. T2

9) CALLING UP MENUS: FIG. 1

9.1) PARAMETERS MENU (

PARA

) (PARAMETERS TABLE “A”)

9.2) LOGIC MENU (

LOGIC

) (LOGIC TABLE “B”)  

9.3) RADIO MENU (

radio

) (RADIO TABLE “C”)

-   IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE 

IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).

In the event of manual programming, the first transmitter assigns the RECEIVER’S 

KEY CODE: this code is required to subsequently clone the radio transmitters.

The Clonix built-in on-board receiver also has a number of important advanced features: 

•  Cloning of master transmitter (rolling code or fixed code).

•  Cloning to replace transmitters already entered in receiver.

•  Transmitter database management.

•  Receiver community management.

To use these advanced features, refer to the universal handheld programmer’s 

instructions and to the general receiver programming guide.

9.4) MENU DEFAULT (

default

)

Restores the controller’s DEFAULT factory settings. Following this reset, you will 

need to run the AUTOSET function again. 

14 -

 BOTTICELLI B CRC 480 D01

D811882 00100_03

Summary of Contents for BOTTICELLI B CRC 480 D01

Page 1: ...MATION POUR PORTES BASCULANTES ET SECTIONALES GARAGENTORANTRIEB FÜR SCHWING UND SEKTIONALTORE AUTOMATIZACIONES PARA PUERTAS BASCULANTE Y SECCIONALES AUTOMATISERINGEN VOOR KANTEL EN SECTIEDEUREN Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Si...

Page 2: ...issaggio Fastening configuration Configuration de la fixation Konfigurierung Befestigung Configuración de fijación Configuratie van bevestiging 1 DFBBFD 2 DCFFCD 3 DCGGCD 4 FBBF 5 EAAE 6 EBBE 7 GBBG A A D B E E F F G B D C C 7x0 5 mm 2 LINEA 3x1 5 mm2 2x0 5 mm 2 5x0 5 mm 2 INSTALLAZIONE VELOCE QUICK INSTALLATION INSTALLATION RAPIDE SCHNELLINSTALLATION INSTALACIÓN RÁPIDA SNELLE INSTALLATIE 2 BOTTIC...

Page 3: ...J 1 2 3 4 C1 P1 5 L1 L2 C C D D B A D Tassello Plug Cheville Dübel Taco Plug Ø 10 V1 V2 V1 4 8 V2 16 4 8 V4 V5 V6 V6 R1 R1 R2 D1 D1 D2 R2 8 4 8 4 8 6 16 8 6 3 8 60 60 V5 D1 V6 D2 V4 V3 6 20 V3 V3 V5 R1 R2 R1 R2 R2 V5 BOTTICELLI B CRC 480 D01 3 D811882 00100_03 ...

Page 4: ...e échelle 1 1 Schneidschablone Maßstab 1 1 Plantilla para corte escala 1 1 Kaliber voor snijden schaal 1 1 88 1 2 3 4 5 2 4 1 3 E14 24V 25W max 253 16 65 378 35 3380 2780 3760 3160 250 146 17 V1 V1 V2 4 8 4 8 16 8 4 V1 4 8 V1 V1 8 30 V1 V2 4 BOTTICELLI B CRC 480 D01 D811882 00100_03 ...

Page 5: ...ampe de courtoisie Hilfsbeleuchtung Luz interior waaklicht Fusibile Fuse Fusible Schmelzsicherung Fusible Zekering COM PED 16 17 JP10 JP2 Connettore scheda opzionale Optional board connector Connecteur carte facultative Steckverbinder Zusatzkarte Conector de la tarjeta opcional Connector optionele kaart Display tasti programmazione Display programming keys Afficheur touches programmation Display P...

Page 6: ... già memorizzato Radio transmitter already memorised Radiocommande déjà mémorisée Bereits gespeicherte Funksteuerung Radiomando ya memorizado Reeds gememoriseerde afstandsbediening Radiocomando da memorizzare Radio transmitter to memorise Radiocommande à mémoriser Zu speichernde Funksteuerung Radiomando que memorizar Te memoriseren afstandsbediening Radiocomando da memorizzare Radio transmitter to...

Page 7: ...esso FINECORSA CHIUSURA ped Attivazione ingresso PEDONALE open Attivazione ingresso OPEN CLS Attivazione ingresso CLOSE amp Inversione per ostacolo Verificareeventualiostacolilungo il percorso ER01 Test fotocellule fallito Verificare collegamento foto cellule e o impostazioni logiche ER10 Errore test hardware scheda Rivelati problemi al circuito di comando motore ER11 Errore test hardware scheda R...

Page 8: ...nte in posizione visibile fissare inoltre alla struttura un cartello di Attenzione Fissareinmodopermanenteunaetichettarelativaalfunzionamentodellosblocco manuale dell automazione e apporla vicino all organo di manovra Assicurarsi che durante la manovra siano evitati o protetti i rischi meccanici ed inparticolarel impatto loschiacciamento ilconvogliamento ilcesoiamentotra parte guidata e parti circ...

Page 9: ...ta binario senza fissarle al telaio della porta Fig L1 o se l al tezza lo consente montare la staffa fissandola all architrave in muratura con tasselli Fig L2 7 Alzare la testa motorizzata fino ad appoggiare il tutto al soffitto e inserirvi le viti di fissaggio che bloccano il binario comprese le viti della staffa di ancoraggio 8 Nel caso in cui il fissaggio della testa motore e del binario non fo...

Page 10: ... di un menu di regolazione dei finecorsa di apertura e chiusura che semplifica la procedura di installazione Procedere come segue Dareavvioadunaoperazionediregolazionefinecorsaportandosinell apposito menu del quadro VENERE D Fig A Alla visualizzazione del messaggio CLOSE portare l anta nella posizione di chiusuradesideratautilizzandoipulsanti UP e DOWN dellacentrale tenendo presente che il pulsant...

Page 11: ...azione radiocomandi ON ON Abilita la memorizzazione via radio dei trasmettitori 1 Premere in sequenza il tasto nascosto P1 e il tasto normale T1 T2 T3 T4 di un trasmettitore già memorizzato in modalità standard attraverso il menu radio 2 Premere entro 10s il tasto nascosto P1 ed il tasto normale T1 T2 T3 T4 di un trasmettitore da memorizzare La ricevente esce dalla modalità programmazione dopo 10s...

Page 12: ... activated STOP STOP input activated PHOT PHOT input activated SWO OPENING LIMIT SWITCH input activated SWc CLOSING LIMIT SWITCH input activated ped PEDESTRIAN input activated open OPEN input activated CLS CLOSE input activated AMP Reverse due to obstacle Check for obstacles in path ER01 Photocell test failed Check photocell connection and or logic settings ER10 Board hardware test error Problems ...

Page 13: ...e public Apply at least one warning light flashing light in a visible position and also attach a Warning sign to the structure Attach a label near the operating device in a permanent fashion with informa tion on how to operate the automated system s manual release Make sure that during operation mechanical risks are avoided or relevant protective measures taken and more specifically that nothing c...

Page 14: ...he help of an adequate support lift the entire motor screw the screws onto the track holding bracket without fixing them to the door frame Fig L1 or if the height allows it fit the bracket to the masonry lintel by means of plugs Fig L2 7 Rest the motor onto the floor taking care not to damage it and fix the articulated bracket to the door frame or to the ceiling 8 In the case where the motor is no...

Page 15: ...possible Thatway allthe automated devices connected can be opened or closed with a single command ConnectallVENEREDcontrolpanelsusingtwistedpaircablingonly proceeding as shown in the diagram in Fig Y When using a telephone cable with more than one pair it is essential to use wires from the same pair The length of the telephone cable between one unit and the next must not be greater than 250 m Atth...

Page 16: ...Remote control programming ON ON Enables wireless memorizing of transmitters 1 Press in sequence the hidden key P1 and normal key T1 T2 T3 T4 of a transmitter that has already been memorized in standard mode via the radio menu 2 Press within 10 sec the hidden key P1 and normal key T1 T2 T3 T4 of a transmitter to be memorized The receiver exits programming mode after 10 sec you can use this time to...

Page 17: ...ntrée STOP PHOT activation entrée PHOTOCELLULE SWO activation entrée FIN DE COURSE OPEN SWc activationentréeFINDECOURSEFERMETURE ped activation entrée PIÉTON open activation entrée OPEN CLS activation entrée CLOSE AMP Inversion pour obstacle Vérifier éventuels obstacles le long du parcours ER01 Essai photocellules échoué Vérifier connexion photocellules et ou configurations logiques ER10 Erreur es...

Page 18: ...s pièces détachées originales pour les opérations d entretien ou les réparations Le Fabricant décline toute responsabilité quant à la sécurité et au bon fonctionnement de l automatisation en cas d utilisation de composants d autres Fabricants Ne modifier d aucune façon les composants de l automatisation sans l autorisa tion expresse du Fabricant Informer l utilisateur de l installation sur les ris...

Page 19: ...stre les diffé rentes combinaisons permettant de fixer l étrier sur le portail basculant 4 Percer le plafond avec une pointe D 10 en respectant les références mar quées précédemment et insérer les chevilles Fig I 5 Bloque le rail à la base fig J réf 1 2 et fig K réf 3 4 5 6 En s aidant d un appui adapté lever tout le moteur visser les vis sur l étrier porte rail sans les visser au châssis de la po...

Page 20: ...ccéder au tableau de commande 11 CONNEXION SÉRIE À TRAVERS LA CARTE SCS1 Fig Y Le tableau de commande VENERE D permet de connecter en les centralisant plusieurs automatisations à travers les entrées et les sorties série prévues à cet effet SCS1 Cela permet d accomplir avec un même commande l ouverture ou la fermeture de toutes les automatisations connectées En vous aidant du schéma de la figure Y ...

Page 21: ...des radiocommandes ON ON Active la mémorisation via radio des émetteurs 1 Appuyez en séquence sur la touche cachée P1 et sur la touche normale T1 T2 T3 T4 d un émetteur déjà mémorisé en mode standard à travers le menu radio 2 Appuyez dans les 10 secondes sur la touche cachée P1 et sur la touche normale T1 T2 T3 T4 d unémetteuràmémoriser Lerécepteursortdumodeprogrammationaprès10secondes durant ce l...

Page 22: ...ktivierung Eingang STOP PHOT Aktivierung Eingang PHOT SWO Aktivierung Eingang ENDSCHALTER ÖFFNUNG SWc Aktivierung Eingang ENDSCHALTER SCHLIESSUNG ped Aktivierung Eingang FUSSGÄNGER open Aktivierung Eingang OPEN CLS Aktivierung Eingang CLOSE AMP Umkehrung wegen Hindernis Auf Hindernisse auf dem Weg überprüfen ER01 Test Fotozellen fehlgeschlagen Überprüfung Anschluss Fotozellen und oder Einstellunge...

Page 23: ...ingestellt worden ist und dass die Schutzsysteme den Betrieb ordnungsgemäß blockieren Verwenden Sie bei allen Wartungs und Reparaturarbeiten ausschließlich Originaler satzteile Die Firma haftet nicht für die Sicherheit und den ordnungsgemäßen Betrieb der Automatik falls Komponenten von anderen Herstellern verwendet werden Nehmen Sie keine Änderungen an den Komponenten der Automatik vor die von der...

Page 24: ...rif 1 2 e Abb K rif 3 4 5 6 Mit Hilfe einer geeigneten Auflage den gesamten Motor anheben die Schrauben am Schienentragbügel anschrauben und nicht am Türrahmen befestigen Abb L1 Alternativ kann wenn die Höhe dies zuläßt der Bügel mit Dübeln am Mauersturz montiert werden Abb L2 7 Den Motorkopf anheben bis alles zusammen an der Decke anliegt Dann die Befestigungsschrauben der Schiene einführen einge...

Page 25: ...Anschließen mehrerer Automatisierungen Auf diese Weise ist es möglich mit einer einzigen Steuerung die Öffnung oder dieSchließungallerangeschlossenenAutomatisierungenauszuführen Befolgen Sie beim Anschließen aller Bedientafeln VENERE D den Schaltplan von Abb Y und verwenden Sie dabei ausschließlichTelefonschleifen BeiVerwendung eines Telefonkabels mit mehreren Leiterpaaren müssen unbedingt die Drä...

Page 26: ...iert die Abspeicherung der Sender über Funk 1 DrückenSienacheinanderdieversteckteTaste P1 unddienormaleTaste T1 T2 T3 T4 eines bereits in der Standardmodalität mit dem Menü Funk abgespeicherten Senders 2 Drücken Sie innerhalb von 10 Sek Die versteckteTaste P1 und die normaleTaste T1 T2 T3 T4 eines abzuspeichernden Senders Der Empfänger verlässt die Programmiermodalität nach 10 Sekunden innerhalb d...

Page 27: ...entrada STOP PHOT activación entrada PHOT SWO activación entrada FINAL DE CARRERA DE APERTURA SWc activación entrada FINAL DE CARRERA DE CIERRE ped activación entrada PEATONAL open activación entrada OPEN CLS activación entrada CLOSE AMP Inversión por obstáculo Comprobar eventuales obstáculos a lo largo del recorrido ER01 Prueba fotocélulas fallida Comprobarconexiónfotocélulasy oconfiguracioneslóg...

Page 28: ...vamente piezas originales para todas las operaciones de manteni miento y reparación La Empresa no se responsabiliza de la seguridad y el buen funcionamiento de la automatización en caso que se utilicen componentes de otros fabricantes No realizar ninguna modificación a los componentes de la automatización si no se cuenta con autorización expresa por parte de la Empresa Instruir al usuario de la in...

Page 29: ...ciones para fijar la abrazadera al portón basculante 4 Perfore el techo con una broca D 10 respetando las referencias anterior mente marcadas e inserte los tacos Fisher Fig I 5 Bloqueelavíaalabase Fig J rif 1 2 e fig K rif 3 4 5 6 Con la ayuda de un apoyo adecuado levante todo el motor atornille los tor nillos a la abrazadera portavía sin fijarlos a la hoja de la puerta Fig L1 o si la altura lo pe...

Page 30: ...0 PROGRAMACIÓN DE LOS TRANSMISORES A DISTANCIA FIG X Este modo no requiere el acceso al cuadro de mando 11 CONEXIÓN SERIAL MEDIANTE TARJETA SCS1 Fig Y El cuadro de mando VENERE D permite mediante entradas específicas y salidas seriales SCS1 la conexión centralizada de varias automatizaciones De este modo se puede con un único mando realizar la apertura o el cierre de todas las automatizaciones con...

Page 31: ...code véase el apartado Clo nación de los Radiotransmisores prog radio Programación de los radiomandos ON ON Habilita la memorización vía radio de los transmisores 1 Pulsar en secuencia la tecla oculta P1 y la tecla normal T1 T2 T3 T4 de un transmisor ya memorizado en modo estándar a través del menú radio 2 Dentro de los 10 seg pulsar la tecla oculta P1 y la tecla normal T1 T2 T3 T4 de un transmiso...

Page 32: ...g START STOP activering ingang STOP PHOT activering ingang PHOT SWO activering ingang EINDAANSLAG OPENING SWc activering ingang EINDAANSLAG SLUITING ped activering ingang VOETGANGERS open activering ingang OPEN CLS activering ingang CLOSE amp Omkering voor obstakel Eventueleobstakelslangshettrajectcontroleren ER01 Test fotocellen mislukt Aansluiting fotocellen en of instelling logica s controleren...

Page 33: ...ren Uitsluitend originele reserveonderdelen gebruiken voor alle onderhouds of repara tiewerkzaamheden Het Bedrijf wijst iedere willekeurige verantwoordelijkheid af uit veiligheidsredenen en vanwege de goede werking van het automatiseringssysteem als er onderdelen van andere fabrikanten gebruikt worden Geen enkele wijziging uitvoeren aan de componenten van het automatiseringssys teem indien niet ui...

Page 34: ...ort te bevestigen 4 Het plafond doorboren met een punt D 10 en hierbij de referenties respec teren die eerder gemarkeerd werden en de pluggen invoeren Fig I 5 De rail aan de basis blokkeren fig J rif 1 2 en fig K rif 3 4 5 6 Met behulp van een adequate steun heel de motor optillen de schroeven op de beugel raildrager vastdraaien zonder deze vast te hechten aan het frame van de deur Fig L1 of indie...

Page 35: ...6 karakters van identificatie installatie in te voeren 10 PROGRAMMERING REMOTE TRANSMITTERS FIG X Deze modaliteit vereist niet de toegang naar het bedieningsbord 11 SERIËLE VERBINDING MIDDELS KAART SCS1 Fig Y HetbedieningsbordVENEREDstaat middelsdesbetreffendeseriëleingangenen uitgangen SCS1 degecentraliseerdeverbindingvanmeerdereautomatiseringen toe Op deze manier is het mogelijk met een enkele b...

Page 36: ...n ON ON Activeert de memorisering via radio van de transmitters 1 In sequens drukken op de verborgen toets P1 en de normale toets T1 T2 T3 T4 van een reeds gememoriseerde transmitter in de standaard modaliteit middels het menu radio 2 Binnen de 10s drukken op de verborgen toets P1 en de normale toets T1 T2 T3 T4 van een te memoriseren transmitter De ontvanger verlaat de modaliteit programmering na...

Page 37: ...lunque momento le modifiche che essa ritiene convenienti per migliorare tecnica mente costruttivamenteecommercialmenteilprodotto senzaimpegnarsiadaggiornare la presente pubblicazione USER WARNINGS GB WARNING Important safety instructions Carefully read and comply with the Warnings and Instructions that come with the product as improper use can cause injury to people and animals and damage to prope...

Page 38: ...ten Bewegungen der Tür führen Bei Rollladenautomatisierungen Überwachen Sie den Rollladen während der Bewegung und halten Sie Personen fern bis er vollständig geschlossen ist Gehen Sie bei der Betätigung der eventuellen Entsperrung mitVorsicht vor da der offene Rollladen bei Brüchen oder Abnutzung herunterfallen könnte Das Brechen oder die Abnutzung der mechanischen Organe der Tür geführter Teil w...

Page 39: ... hetbewegenderolluikcontrolerenendepersonenop eenafstandhoudentotdezenietvollediggeslotenis Oplettenwanneerdedeblokkeringwordt geactiveerd indien aanwezig omdat een open rolluik snel zou kunnen vallen in aanwezigheid van slijtage of gebreken Het stukgaan of de slijtage van mechanische onderdelen van de deur geleide deel zoals bijvoorbeeld kabels veren steunen klepscharnieren geleiders kan gevaren ...

Page 40: ...40 BOTTICELLI B CRC 480 D01 D811882 00100_03 ...

Reviews: