INSTALLATION MANUAL
Logic
Definition
Default
Cross out
setting
used
Optional extras
FAST CLS.
Fast closing
0
0
Logic not enabled
1
Closes 1 second after the photocells are cleared before waiting for the set TCA to elapse.
STEP-BY-STEP
MOVEMNT
Step-by-step
movement
1
0
Inputs configured as Start E, Start I, Ped
operate with 4-step logic.
step-by-step mov.
2 STEP
3 STEP
4 STEP
CLOSED
OPENS
OPENS
OPENS
DURING
CLOSING
STOPS
OPEN
CLOSES
CLOSES
CLOSES
DURING
OPENING
STOP + TCA STOP + TCA
AFTER STOP
OPENS
OPENS
OPENS
1
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse
during closing reverses movement.
2
Inputs configured as Start E, Start I, Ped
operate with 2-step logic. Movement
reverses with each pulse.
PRE-ALARM
Pre-alarm
0
0
The flashing light comes on at the same time as the motor(s) start.
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
HOLD-TO-RUN
Deadman
0
0
Pulse operation.
1
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
2
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman
mode is enabled which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
IBL OPEN
Block pulses during
opening
1
0
Pulse from inputs configured as Start E, Start I has effect during opening.
1
Pulse from inputs configured as Start E, Start I has no effect during opening.
*IBL TCA
Block pulses during
TCA
0
0
Pulse from inputs configured as Start E, Start I has effect during TCA pause.
1
Pulse from inputs configured as Start E, Start I has no effect during TCA pause.
IBL CLOSE
Block pulses during
closing
0
0
Pulse from inputs configured as Start E, Start I has effect during closing.
1
Pulse from inputs configured as Start E, Start I has no effect during closing.
OPEN IN OTHER
DIRECT.
Open in other
direction
0
0
Standard operating mode (left barrier).
1
Opens in other direction to standard operating mode (right barrier).
SAFE 1
Configuration of
safety input SAFE 1.
72
0
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
SAFE 2
Configuration of
safety input SAFE 2.
74
6
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
IC 1
Configuration of
command input IC 1.
61
2
0
Input configured as Start E.
1
Input configured as Start I.
2
Input configured as Open.
3
Input configured as Close.
IC 2
Configuration of
command input IC 2.
62
3
4
Input configured as Ped.
5
Input configured as Timer.
GIOTTO BT A 30-60 S U / GIOTTO BT A 30-60 U -
45
D812433 00100_06
ENGLISH