ENGLISH
Parameter
min. max. Default Personal
Definition
Description
Op. speed
20
80
45
Speed during opening
Running speed during opening [%]
Sets the running speed that the barrier must reach during opening, as a
percentage of the maximum speed the actuator can reach.
cl speed
20
80
45
Speed during closing
Running speed during closing [%]
Sets the running speed that the barrier must reach during closing, as a
percentage of the maximum speed the actuator can reach.
aintenance
0
250
0
Programming number of
operations for maintenance
threshold
[in hundreds]
Allows you to set a number of operations after which the need for main-
tenance will be reported on the AUX output configured as Maintenance
or Flashing Light and Maintenance .
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
(
***)=Reference for universal handheld programmer.
TABLE “B” - LOGIC - (
LOGIC
)
Logic
Definition
Default
Cross out
setting
used
Optional extras
otor type
Spring type or bar
length
0
0
Short bars 20-45, generally standard spring
1
Long bars 45-60, generally XL spring
TCA
Automatic Closing
Time
1
0
Logic not enabled
1
Switches automatic closing on
FAST CLS.
Fast closing
0
0
Logic not enabled
1
Closes 1 second after the photocells are cleared before waiting for the set TCA to elapse.
STEP-BY-STEP
OVE NT
Step-by-step
movement
1
0
Inputs configured as Start E, Start I, Ped
operate with 4-step logic.
step-by-step mov.
2 STEP
3 STEP
4 STEP
CLOSED
OPENS
OPENS
OPENS
DURING
CLOSING
STOPS
OPEN
CLOSES
CLOSES
CLOSES
DURING
OPENING
STOP + TCA STOP + TCA
AFTER STOP
OPENS
OPENS
OPENS
1
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse
during closing reverses movement.
2
Inputs configured as Start E, Start I, Ped
operate with 2-step logic. Movement
reverses with each pulse.
PRE-ALAR
Pre-alarm
0
0
The flashing light comes on at the same time as the motor(s) start.
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
HOLD-TO-RUN
Deadman
0
0
Pulse operation.
1
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
2
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman
mode is enabled which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
IBL OPEN
Block pulses during
opening
1
0
Pulse from inputs configured as Start E, Start I has effect during opening.
1
Pulse from inputs configured as Start E, Start I has no effect during opening.
*IBL TCA
Block pulses during
TCA
0
0
Pulse from inputs configured as Start E, Start I has effect during TCA pause.
1
Pulse from inputs configured as Start E, Start I has no effect during TCA pause.
IBL CLOSE
Block pulses during
closing
0
0
Pulse from inputs configured as Start E, Start I has effect during closing.
1
Pulse from inputs configured as Start E, Start I has no effect during closing.
OPEN IN OTHER
DIRECT.
Open in other
direction
0
0
Standard operating mode (left barrier).
1
Opens in other direction to standard operating mode (right barrier).
SAFE 1
Configuration of
safety input SAFE 1.
72
4
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
SAFE 2
Configuration of
safety input SAFE 2.
74
6
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
GIOTTO BT A ULTRA 36 -
31
D814017 2F
A00_02
Summary of Contents for GIOTTO BT A ULTRA 36
Page 64: ......