Thank you for buying this product. Our company is sure that you will be more
than satisfied with the performance of the product. This product is supplied
with a “
WARNINGS
” leaflet and an “
INSTRUCTION MANUAL
”. These
should both be read carefully as they provide important information about
safety, installation, operation and maintenance. This product complies with
recognised technical standards and safety regulations. We declare that this
product is in conformity with the following European Directives: 89/336/CEE,
73/23/EEC, 98/37/EEC and subsequent amendments.
1) GENERAL OUTLINE
Compact electromechanical barrier suitable for limiting private areas, parkin-
gs, access areas for vehicles only. Available for passageways from 3 to 5
metres. Adjustable electromechanical limit devices ensuring a correct stop
position for the boom. In case of intensive use, a thermal sensor activates
the cooling fan.
The emergency release device for manual manoeuvre is controlled by a
personalised key lock.
The actuator is always supplied for left-hand side fitting.However, when
necessary, the opening direction can be reversed by means of simple
operations.
The CBO mod. foundation base (on request) makes barrier installation
easier.
Appropriate fittings make it easy to install accessories without needing to
drill any holes.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
• The “
Warnings
” leaflet and “
Instruction booklet
” supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children’s reach.
• Keep the instructions together with the technical brochure for future
reference.
• This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
• The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
• The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
• Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
• Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
• Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing, according to and in compliance with the applicable directives
and technical standards.
• Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
• The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers’ components are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised
by the company.
• Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation ope-
ration area.
• Keep radio control or other control devices out of children’s reach, in
order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
• Anything which is not expressly provided for in the present instructions,
is not allowed.
• Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
3) TECHNICAL SPECIFICATIONS
MOOVI 30-50
Power supply: ........................................................... 230V
~
.±10% 50Hz (*)
Absorbed power: ................................................................................ 300W
Motor: ............................................................................ 1400 min
-1
, 4 poles
Capacitor: ..........................................8µF 450V (230V) :32µF 250V (110V)
Absorption: ................................................................................0.8 A :1.6 A
Insulation class: ......................................................................................... F
Ventilation intervention temperature: ..................................110°C (winding)
Circuit-breaker intervention temperature: .................. 130°C (self-resetting)
Reduction gear lubrication: ............................................. Permanent grease
Max torque: ....................................... MOOVI-30 85Nm: MOOVI-50 250Nm
Opening time: ................................................ MOOVI-30 4s : MOOVI-50 8s
(Aluminium) bar length: .............. MOOVI-30 3m max : MOOVI-50 5m max.
Impact reaction (electric edge): ............................ Stop or stop and reverse
Limiting devices: ................................ Electric, incorporated and adjustable
Manual manoeuvre: ......................................................... Quick key release
No. manoeuvres in 24 hour: .................1200 (MOOVI-30) :600 (MOOVI-50)
Working temperature: ........................................................... -10°C ÷ +55°C
Degree of protection: ............................................................................ IP24
Actuator weight (without bar): .............................................356N (~35.6 kg)
Dimensions: ................................................................................... See fig.1
ALPHA-BOM CONTROL PANEL
Power supply: ........................................................... 230V
~
±10% 50Hz (*)
Loadless absorption: ...................................................................... 100 mA
Accessory output power: ...............................................24V
~
200 mA max
Max. motor power absorbed: ............................................................. 500W
Limits switch: ......................................................................... electric switch
Working time: ......................................................... adjustable from 1 to 30s
Working temperature: ................................................................ -10 +55 °C
(*) Special power voltages available on request.
4) OPTIONAL ACCESSORIES (Fig.17)
-
CBO.
Foundation base
-
MOOVI PRM.
Antishearing Kit
-
MOOVI 130.
Kit for Cellula 130 fixing post
-
FAF.
Fixed fork for boom rest
-
MOOVI GA.
Movable rod for boom rest (Only for MOOVI 50)
-
MOOVI GAMA.
Movable cushioned rod for boom rest
-
SB.
Skirt already assembled to the boom
-
Safety edge
BIR
-
MOOVI LIGHT.
Light kit for booms from 3m to 4.5m
-
MOOVI LIGHT 1.
Light kit for booms from 5m to 6m
-
MOOVI PCA.
Lower or upper boom covering contour
For further information about installation and use of the accessories, make
reference to their respective instruction manuals.
5) FOUNDATION PLATE
(Fig.2)
- Prepare a foundation hole suitable for the particular kind of ground.
- Layout several raceways for the electric cables to pass through.
- Position the screws supplied with the CBO mod. base into the 4 fixing
holes with the thread facing upwards. Weld the 4 screw heads to the
base and protect the welds with rust preventer. Position the base so that
it protrudes about 20mm from the floor (fig.2).
- Fill the hole with concrete, checking the position of the base in both
directions by means of a level, and let the cement harden.
6) FITTING OF THE ACTUATOR
WARNING! The barrier must be exclusively used for vehicles to
drive through. Pedestrians must not walk within the operator manoeu-
vring area.
An appropriate pedestrian passageway must be provided for.
The passageway must be suitably indicated by means of the warning
signs illustrated in Fig.10.
WARNING: before opening the door, make sure that the spring has
been unloaded (rod at 43°).
The door of the box must face the inside of
the property. When standing in the middle of the passageway, if the box
is on the left the barrier opens to the left, and if the box is on the right the
barrier opens to the right.
INSTALLATION MANUAL
ENGLISH
MOOVI 30-50 Ver. 06
-
13
D811386_06
P:13