background image

USER‘S MANUAL

Carefully read these instructions before starting 

and using your log splitter!

Südharzer Maschinenbau GmbH

Helmestraße 94 ∙ 99734 Nordhausen/Harz

Receptionist: 

03631/6297-0 ∙ 

-111 

Internet: www.bgu-maschinen.de

e-mail: info@bgu-maschinen.de

- Set-up &  in

  stallation

- Use

- Maintenance

- Accessories

UNIVERSAL LOG SPLITTER 

SP 30 HZH/S - HEH/S - HZEH/S

We manufactu-

re in Germany

Summary of Contents for SP 30 HEH/S

Page 1: ...litter S dharzer Maschinenbau GmbH Helmestra e 94 99734 Nordhausen Harz Receptionist 03631 6297 0 111 Internet www bgu maschinen de e mail info bgu maschinen de Set up in stallation Use Maintenance Ac...

Page 2: ...6 Operating instructions 12 5 7 Adjusting the ram stroke to a different log length 12 5 8 Two hands control and auto cycle control valve for fast speed operation mode 12 6 HANDLING AND TRANSPORTATION...

Page 3: ...ents and feature additions information in this document is subject to change without notice If you are experiencing a problem or functional trou ble on your machine please read the trouble shooting se...

Page 4: ...ithin latest 2 days from de livery Therefore delivery must be collected and inspected within this term Later claims shall be disregarded In case of assumed but not visually clear transport damages mak...

Page 5: ...5 Steel stand 2 PRODUCT OVERVIEW Log lift Push block Log carriage Splitting wedge Wood collection table Hydraulic ram...

Page 6: ...s stand at safe distance from machine moving parts 3 Machine safety label p max 220 bar Maximum operating pressure is 200 bars 4 Machine safety label Pinched hands danger Wear suitable protective glov...

Page 7: ...7 9 Personal protection pictogram Wear ear plugs and goggles 10 Personal protection sign Mind these instructions 11 Machine safety label CAUTION mind for driveshaft revolutions...

Page 8: ...ept in a suitable location selected by the customer for safest operation Make sure that the equipment stands on a safe stable foundation The working area around the machine must be kept as clear as po...

Page 9: ...responsible for custo mers claims or resulting damages Customers are to operate the machine in strict accordance with these installation operation maintenance and repair instructions Lack of complianc...

Page 10: ...uctor cable Operating the splitter while the motor turns in the wrong direc tion may cause major even permanent damages of the hydraulic pump 5 2 Hydraulic speci cations This professional horizontal l...

Page 11: ...and seal eventual leaks if required Do not check for leaks with your hand Leaks can be located by passing a piece of cardboard or wood around the suspected leak and looking for discoloration High pres...

Page 12: ...top plate on the splitter left hand side The location of the stop plate will set the ram stop It is possible to set the ram stop at 65 and 125 cm For shorter stroke than 95 cm please use the extension...

Page 13: ...driveshaft joint and drive the tractor with caution so to avoid transport damages to the machine 6 1 Transport asset To prepare the machine for road transportation the following steps should be follow...

Page 14: ...hout oil or with a low oil level When this happens air is likely to reach inside the hydraulic loop Failure to maintain due oil level may cause poor run ning and irregular splitter operation very roug...

Page 15: ...itter cycle three or four times and let the air blow out of the hydraulic loop before clo sing the cap Your log splitter is now ready to start again All hose connections must be always tight and seale...

Page 16: ...y stated in this manual Dismantling procedure Take good note please each and every dismantling task must beper formed by authorized service centres or trained skilled staff only Pull the machine down...

Page 17: ...A 1 x 32 fuses 1 x 32 fuses Motor power kW 7 5 7 5 Motor speed RPM 1450 1450 Splitter height Transport asset mm 1750 1750 1750 Splitter width Transport asset mm 3100 3100 3100 Width mm 4050 4050 4050...

Page 18: ...commend use a portable residual current device PRCD unless you already have a re sidual current device RCD in your house assuring safety and protec tion up to max 0 03A nominal fault current Component...

Page 19: ...ed during the split ting cycle Do not remove any other safety and protection device from the machine WARNING splitting without due safety devices might result into se rious injures to the operator or...

Page 20: ...d or modi ed by the customer or other thirds or overloaded No warranty applies to consumable parts for instance V belts bla des tools and other implements and to adjustment calibration works 13 EXTEND...

Page 21: ...ve2004 108 EEC Other applicable Standards and technical speci cations EC Standard Draft prEN 609 Log splitters DIN EN 55014 T1 DIN EN 55014 T2 DIN EN 50104 DIN EN 61000 3 2 DIN EN 61000 3 3 Type certi...

Page 22: ...22...

Page 23: ...23...

Page 24: ...4 99734 Nordhausen Harz Service Tel 03631 6297 104 Fax 03631 6297 111 Internet www bgu maschinen de e mail info bgu maschinen de Subject to changes without notice Form 2029 11 11 2016 Rev D Form 2030...

Reviews: