VoIP-1 Front
Front Panel Information
The VoIP-1 LEDs are as follows (from left to right when viewing the front of the chassis):
1. 24V DC power 1
2. 24V DC power 2
3. Fault
4. Activity
5. Status
6. Line 1 Status
7. Line 1 In Use
8. Line 2 Status
9. Line 2 In Use
10. Line 3 Status (functional for VoIP-1-4 model only)
11. Line 3 In Use (functional for VoIP-1-4 model only)
12. Line 4 Status (functional for VoIP-1-4 model only)
13. Line 4 In Use (functional for VoIP-1-4 model only)
Power (Chassis Indicator)
The VoIP-1 has two power indicators. If power is applied to one or both 24V DC power connectors, the
corresponding LED will be on.
Off
– The power connection is not available or not within the voltage range.
Solid green
– The unit is receiving power.
Fault (Chassis Indicator)
There are two types of chassis Faults that will be reported depending on the severity of the problem.
Audio may still be passing, but if the condition causing the warning is not corrected, a failure may occur.
Flashing amber
– A warning has occurred, meaning some aspect of the unit is not performing
within normal specification.
Solid amber
– A Fault has occurred, meaning some aspect of the unit has failed and audio may not
be passing.
Activity (Chassis Indicator)
The VoIP-1 has an activity LED that will illuminate to show the configuration status of the unit.
Off
– The unit is not configured.
Solid green
– The unit is configured.
Status (Chassis Indicator)
The VoIP-1 has a tri-color Status LED that indicates the health of the hardware.
Solid green
– The unit is powered up and working normally.
Flashing amber
– Shown during the power-up self-test.
Solid red
– The unit experienced a problem during the power-up self-test.
Status
Flashing green
– When trying to complete SIP registration.
Solid green
– When SIP registration is complete and the VoIP line is available.