ENGLISH
14
CONTAINER CAPACITY
Coffee bean container
kg 1,7
Instant coffee
kg 0,45
Barley
Kg 0,85
Milk
kg 0,55
Creamer
kg 1,20
Chocolate
kg 3,00
Tea
kg 2,00
Frozen-dry tea
kg 1,00
Broth
kg 1,25
Sugar
kg 1,7
Caps
(In the AUTOMATIC version only)
N° 200
Spoons
(In the AUTOMATIC version only)
N° 200
Height
mm 745
Width
mm 510
Depth
mm 600
Weight
kg 50
Power frequency
220-230V; 50Hz
Power frequency *
220V; 60Hz
Water supply connection
3/4” gas
Electrical supply connection
CEE 7/7 plug
Electrical supply connection *
NBR 14136:2001 plug
Electrical supply connection *
IRAM 2073 10A plug
2.1
KNOWING THE DISTRIBUTOR
Machine description
SEMI-AUTOMATIC versions (Fig.2.2A)
1
Coffee group and grinder
2
Container units for soluble drinks
3
Coffee bean container
4
Coin mechanism
5
Switching
6
Fuse T 3,15A
7
Master board
8
Espresso boiler
9
Second boiler
(only mod.LEI200 E5S DC PD A/R SEMIAUTO-LEI200 E5S
DC PD A/R SEMIAUTO LCD)
10
Dispensing chamber
11
Monitor LCD
(only mod. LEI200 E5S MC PD A/R SEMIAUTO LCD -LEI200
E5S DC PD A/R SEMIAUTO LCD )
12
Keyboard
13
Keyboard cards
14
Display control board
15
Coffee grounds container
16
Cup holder
AUTOMATIC versions (Fig.2.2B)
1
Coffee group and grinder
2
Container units for soluble drinks
3
Coffee bean container
4
Coin mechanism
5
Switching
6
Fuse T 3,15A
7
Master board
8
Espresso boiler
9
Second boiler
(only mod.LEI200 E4S DC PD A/R AUTO-LEI200 E4S DC PD
A/R AUTO LCD)
10
Dispensing chamber
11
Monitor LCD
(only mod.LEI200 E4S MC PD A/R AUTO LCD-LEI200 E4S
DC PD A/R AUTO LCD)
12
Keyboard
13
Keyboard cards
14
Display control board
15
Coffee grounds container
16
Spoons column
17
Cup column
2.2 Modelli
The following terms are used to identify the various models of automatic
vending machine:
LEI200 E4S MC PD A/R AUTO
(Automatic single boiler without LCD)
LEI200 E4S DC PD A/R AUTO
(Automatic double boiler without LCD)
LEI200 E5S MC PD A/R SEMIAUTO
(Semiautomatic single boiler without LCD)
LEI200 E5S DC PD A/R SEMIAUTO
(Semiautomatic double boiler without LCD)
LEI200 E4S MC PD A/R AUTO LCD
(Automatic single boiler with LCD)
LEI200 E4S DC PD A/R AUTO LCD
(Automatic double boiler with LCD)
LEI200 E5S MC PD A/R SEMIAUTO LCD
(Semiautomatic single boiler with LCD)
LEI200 E5S DC PD A/R SEMIAUTO LCD
(Semiautomatic double boiler with LCD)
The manual is compiled for the most complete model: it is therefo-
re possible, to find descriptions or explanations not related to your
machine.
The wiring and hydraulic diagrams are inside the vending machine.
III - SAFETY NORMS
Before using the automatic distributor, read this manual care-
fully.
– The installation and maintenance operations must be performed exclusi-
vely by qualified technical personnel.
– The user must not in any circumstance be able accede to those parts of
the automatic distributor that are protected and require a tool in order
to be accessible.
– The knowledge and the absolute respect, from a technical point of view of
the safety instructions and of the danger notices contained in this manual,
constitute the basis for the operation , in conditions of minimum risk, of
the installation, starting and maintenance of the machine.
Always disconnect the POWER CABLE before maintenance or
cleaning interventions.
ABSOLUTELY DO NOT INTERVENE ON THE MACHINE AND DO NOT
REMOVE ANY PROTECTION BEFORE THE COOLING OF THE HOT PARTS!
– The functional reliability and optimization of machine’s services are
guaranteed only if original parts are used.
– In order to guarantee normal operation, the machine must be installed
in areas that the environmental temperature is between a minimum of
+1°C and a maximum of +50°C end humidity of not over 85%.
– In order to guarantee a regular operation, always maintain the automatic
distributor in perfect cleaning conditions
– If at the moment of the installation, if conditions differing from those
indicated in the present manual, or should the same undergo changes
in time, the manufacturer must be immediately contacted before use of
the machine.
– Also check that any other eventual norms or regulations as laid down by
national or local legislation are taken into account and applied.
When calling it is advisable to be able to give the following information:
The data registered on the serial number label (Fig.1.1)
version of program contained in the microprocessor (Adhesive label on
the component installed on board) (Fig.1.2).
Bianchi Industry
declines any responsibility for damages caused to people
or belongings in consequence to:
Incorrect installation
Inappropriate electrical and/or water connection.
Inadequate cleaning and maintenance
Not authorized modifications
Improper use of the distributor
Not original spare parts
– Under no circumstances is
Bianchi Industry
obliged to compensate for
eventual damage resulting from the forced suspension of drink deliveries
as the result of faults.
– Installation and maintenance operations , must be done exclusively by
qualified technical personnel with prior training for carrying out these
duties.
– For refilling use only food products that are specific for automatic vending
machines.
– The automatic distributor is not suitable for external installation. The
machine must be installed in dry places, with temperatures that never
go below 1°C it must not be installed in places where cleaning is done
with water hoses (ex. big kitchens.).
Do not use water jets to clean the machine.
This device is not intended for use by individuals (including children) with
reduced physical, sensorial or mental capacities, or by individuals without
the required knowledge and experience, unless said individuals have been
instructed on the use of the device and are duly supervised by a person
responsible for their safety.
Children must be monitored to ensure that they do not play with the device,
or use it as though it were a toy.
Access to the service area is allowed only by personnel that have
been specifically trained accordingly and that have acquired
practical experience on the devices.
+039. 035.45.02.111
*
Special versions for the domestic market
Possible technical problems that could occur are easily resolvable consulting
this manual ; For further information, contact the distributor from whom
the machine has been purchased, or contact
Bianchi Industry’s
Technical
Service at the following numbers:
WATER SUPPLY
from main supply with pressure between 0,05 and 0,65 MPa (0.5 and 6.5 bar)
2.0 TECHNICAL CHARACTERISTICS
(Fig.2.1)
The electrical characteristics of the models are outlined on the
rating plates inside the vending machines.
Summary of Contents for LEI200 E4S MC PD A/R AUTO
Page 55: ...55 3 1 3 3 4 1 4 4 4 5 4 2 4 3 3 2 50 Kg 2 18 4 6 4 7 4 8 ...
Page 56: ...56 4 9 4 10 4 11 4 12 4 13 4 14 6 1 4 16 4 17 4 18 4 19 4 20 4 21 4 15 ...
Page 58: ...58 6 15 6 16 7 2 7 1 7 3 7 4 7 5 7 6 7 8 7 7 7 9 6 14 ...
Page 66: ......
Page 71: ......
Page 72: ...Cod 11124111 Ed 05 2017 Rev 2 ...