background image

2

VEGA

Key at the disposal of the

INSTALLATION technician

Tools  necessary  for  undertaking

interventions on the automatic dispenser.

SOCKET SPANNERS

n° 5,5

n° 7

n° 8

n° 10

n° 20

n° 22

SPANNERS (fork type)

n° 7

n° 8

n° 10

n° 12

n° 14

SCREWDRIVERS

Small size

Medium size

Large size

Normal cross

Small cross

Medium cross

Large cross

Of Teflon, small size for Trimmer regulation.

RATCHET SPANNER no.14

TESTER

ELECTRICIAN’S SCISSORS

PROGRAMMING KIT

Keys  at  the  disposal  of  the

MAINTENANCE and INSTALLATION

technicians

This  key  can  also  be  given  to  the

maintenance  technician  exclusively

authorized  to  undertake  the

operations as described in chapter 8.0

Summary of Contents for VEGA 600

Page 1: ...ributor see operations indicated in chapter 9 0 In the event of a fault the maintenance technician must call the installation technician INSTALLATION TECHNICIAN The installation technician is defined...

Page 2: ...4 SCREWDRIVERS Small size Medium size Large size Normal cross Small cross Medium cross Large cross Of Teflon small size for Trimmer regulation RATCHET SPANNER no 14 TESTER ELECTRICIAN S SCISSORS PROGR...

Page 3: ...the part of the various operators until the dismantlement and or scrapping of the machine In case of loss or damage of the present manual it is possible receive a new copy making application to the ma...

Page 4: ...advisable to be able to give the following information l The data registered on the serial number label Fig 1 1 l The version of the programme contained in the microprocessor adhesive label applied to...

Page 5: ...0 SX 07021011 L16 pitch 22 mm 80 DX 07020311 L16 pitch 30 mm 68 DX 07018511 L16 pitch 35 mm 68 DX 07018111 L16 pitch 37 mm 80 DX 07018711 L16 pitch 45 mm 68 DX SX 07018311 L16 pitch 45 mm 68 SX 070198...

Page 6: ...3 0 GENERAL TECHNICAL DESCRIPTIONS 3 1 Machine description Fig 3 1 1 External keyboard 2 Electronics board MASTER 3 Product drawers 4 Spiral 5 Electrical group 6 Cooling unit 7 Coin mechanism 8 Dispe...

Page 7: ...descriptions or explanations which do not apply to every machine 3 4 Basic operation concepts In normal operation the distributor is in stand by The delivery cycle is activated by inserting the neces...

Page 8: ...rent film in polypropylene Fig 4 2 The automatic distributor will be delivered packed assuring both a mechanical protection and protection against damages from the external environment On the package...

Page 9: ...chamber Fig 4 6 Open the distributor door and remove the adhesive tape from the following components l spirals example in Fig 4 7 l coin box l skirting board Remove the polystyrene blocking the drawer...

Page 10: ...installed in areas that the environmental temperature is between a minimum of 1 C and a maximum of 32 C end humidity of not over 70 In order to guarantee a regular operation always maintain the automa...

Page 11: ...den Nuova Bianchi S p A declines all responsibility for damages product from the non observance of the aforesaid norms Should the power cable be found to be damaged immediately disconnect from the pow...

Page 12: ...n Fig 6 7 pos 1 For some operations is however necessary operate with the door open but with the distributor connected It is possible for qualified technical personnel to operate in this way by insert...

Page 13: ...ecial slits as indicated in the figure 6 11 For the number to be given to each selection check Chapter 9 2 3 Change spiral number 6 4 3 Payment system installation The distributor does not have a paym...

Page 14: ...ION menu which express the status enabled or disabled of a particular function fall within this category Some of the selection keypad keys are used for programming see figure 7 2 and more precisely n...

Page 15: ...is displayed pressing ENTER you accede to the latter pressing the next function will be displayed pressing ESC you exit from the sub menu of operation see example N B If you are in selection mode you...

Page 16: ...DATA CLOCK Note The discounts and clock menus are only displayed if the clock chip is present automatically sensed by the card The menus relative to the MDB coin box the last three are only displayed...

Page 17: ...rotation time motor time 04 0 is the maximum activation time of each motor Do not change at all Motor timeout spiral motor timeout 0 25 0 s Testing password for protected menu 88000 Motor zero set mot...

Page 18: ...ess Enter to accede to the price table programming on the display appears Price 0 0000 set using the keys digit For free vends it is sufficient to set the vending price at zero Press ENTER again to co...

Page 19: ...01 to Discount 30 as many as the vending prices Press ENTER once on the display appears Discount 01 0000 with the keys digit the discount setting is effected Press ENTER to confirm the value set and o...

Page 20: ...ON OFF Using the key the desired option is chosen ON yes or OFF no Choose OFF to go to programming of the individual price for each every individual selection as follows S 11 Price 01 Use the or keys...

Page 21: ...versions Pan for versions with perishable products VEGA 850 VEGA 700 Decimal point display the amount with a decimal point 00000 0000 0 000 00 00 000 Code new programming access code 00000 99999 the P...

Page 22: ...nd to the same vending machine channels Press ENTER once on the display appears Coins 1 0050 with the keys e digit the value is changed Press ENTER to confirm the set modification and anyhow the value...

Page 23: ...or resetting the auditing data Pressing the key take you though the menu up to the desired function pressing the enter key gives access to the first data of the function selected by pressing ENTER aga...

Page 24: ...B It is possible that these two values are different from one distributor to another Specifications for the Snack or Combined configuration the variation fields are shown Tank temp Vega temperature 6...

Page 25: ...0 6 decimals Conv Fact conversion factor 0 999999 Currency Euro conv Selects conversion either from currency into euro or from euro into currency On Off Visualization point Position of the decimal poi...

Page 26: ...he coin box 0 9999 Coin change Engages the change lever On Off Coin 1 engage Activates coin 1 On Off Coin 16 engage Activates coin 16 On Off Note the programming of the coin engagement function will o...

Page 27: ...27 VEGA Fig 7 14 7 2 11 MDB PIPE FILLING Fig 7 14 MDB pipe filling Esc to escape From this menu it is possible to enter coins into the coin box without any updating of the credit on the card...

Page 28: ...28 VEGA Fig 7 15 7 2 12 MDB PIPE EMPTYING Fig 7 15 Coin 1 key 3 empty Coin 16 key 3 empty On pressing key 3 the selected coin will be delivered...

Page 29: ...ig 7 16 7 2 13 EXECUTIVE DATA Fig 7 16 Diff ESC Engaged the differentiated ESC Option On Off Price holding Engages the price holding option On Off Note if both the parameters are ON differentiated ESC...

Page 30: ...sets the time for switch on 2 00 00 23 59 End 2 sets the time for switch off 2 00 00 23 59 Note if start is great or equal to end the switch on band is not engaged Discount Start 1 sets the start tim...

Page 31: ...ist s On application of the HACCP certain hygienic regulations are laid down for company self checking procedures concerning Cleaning of the premises Product transportation Machinery maintenance Waste...

Page 32: ...nents make sure that the latter is switched off Entrust the operations mentioned here below to qualified personnel If the operations require that the distributor be switched on entrust them to special...

Page 33: ...h spiral can rotate by 45 at a time see fig 9 3 9 2 2 Spiral replacement It is possible to replace the spirals with others with a pitch that is suitable for the product to be delivered To carry out th...

Page 34: ...even selection motor 12 22 etc by one slot to the left replace the 68 spiral with the 80 spiral of the required apply the guide under the spiral taking care to bend the clamp tabs again 9 2 4 Change h...

Page 35: ...disconnected Replacement of VEGA 600 model light Fig 9 8 open the distributor flap loosen the fixture screws of the glass section Fig 9 9 extract the light guard element replace the neon light check...

Page 36: ...r electrically unload all the products from the trays Fig 9 12 wash all the parts in contact with foodstuffs in accordance with the above descriptions clean all the internal and external surfaces of t...

Page 37: ...CAPACITY Variable according to the number and pitch of the spirals Height mm 1620 Width mm 700 Depth mm 750 Weight kg 200 Feed voltage 230 V Feed frequency Hz 50 Installed power 1 from 0 29 kW to 0 3...

Page 38: ...38 VEGA Bianchi FIG 10 1 10 2 Machine description Fig 10 1 1 External keyboard 2 Power card 3 Product drawers 4 Spiral 5 Electrical group 6 Cooling unit 7 Coin mechanism 8 Dispensing chamber...

Page 39: ...ng any operations ensure that the electricity supply of the distributor has been disconnected Dismantle the guard casing of the Antares power card Fig 10 2 Connect the top part of the connection cable...

Page 40: ...Fig 10 5 Secure the keyboard using the four threaded screws supplied Then proceed to remove the Master card casing Fig 10 6 pos 1 and connect the button panel cable Fig 10 7 Connect the relative flat...

Page 41: ...DX 07018211 L16 pitch 60 mm 68 DX SX 07018911 L16 pitch 60 mm 68 SX 07019611 L16 pitch 60 mm 80 DX 07019411 L16 pitch 75 mm 68 DX 07018411 L16 pitch 77 mm 68 DX SX 07019311 L16 pitch 77 mm 68 SX 07019...

Page 42: ...42 VEGA FIG 10 9 1 2 7 8 3 4 6 5 10 5 Machine description Fig 10 9 1 External keyboard 2 Master board 3 Product drawers 4 Spiral 5 Electrical group 6 Cooling unit 7 Coin mechanism 8 Dispensing chamber...

Page 43: ...beginning any operations ensure that the electricity supply of the distributor has been disconnected Remove the rear guard on the Pegaso as indicated in Fig 10 10 Connect the connection cable of the...

Page 44: ...oducts as described in the relative paragraph 11 0 DISMANTLEMENT Proceed with the emptying of the products and of the water as described in the previous paragraph For the dismantlement we advise to di...

Page 45: ...mode No delivery is therefore possible Check the alarms during maintenance Alarm Scale factor This alarm is only active if the executive coin box is activated not in price holding mode or MDB It occur...

Reviews: