ADVANCED COMMISSIONING
Fig. 8.19
•
Press buttons
or
to display the
"PM11"
program of the pump post-circula
-
tion (Fig. 8.20).
Fig. 8.20
•
To modify the programmed SET, act on
buttons
or
and wait for the pro
-
grammed number to flash (Fig. 8.21). Each
step increased or decreased corresponds to
1 second.
Fig. 8.21
•
To exit programming, press button
.
8.4 Selecting the reignition fre-
quency
When the boiler functions in normal on/off
heating mode, the minimum time between two
ignitions is set at three minutes (re-ignition fre
-
quency).
This time can be changed by a minimum of
zero to a maximum of eight and a half min
-
utes.
•
Enter the "programming mode" by sequen
-
tially
pressing keys 13 - 16 - 17 (Fig. 8.22)
for 10 seconds at the same time until the
letters
P01
on the LCD display, indicating
that "parameter 01" (Fig. 8.23) has been
activated.
Fig. 8.22
10
11
12
13 14
15
16
17
Fig. 8.23
•
Scroll the various parameters using keys 16
or 17 until the letters
P10
are displayed on
the LCD display, indicating that "parameter
10" (Fig. 8.24) has been activated.
Fig. 8.24