- 64 -
INST
ALLA
TION
ADVANCED COMMISSIONING
•
It is possible to modify parameter 10 by
00=
0s to
100=
510s using keys 10 or 11
(each increase or reduction by a unit on
the display corresponds to 5 seconds). Ex.
36=180 seconds.
•
The writing
P10
-
SEt
alternates on the dis-
play (Fig. 8.25).
Fig. 8.25
•
By pressing key 13 (Fig. 8.22) confirmation
of the inserted value is obtained.
•
Press keys 16 or 17 (Fig. 8.22) to exit with
-
out changing the value.
•
Exiting the “programming mode” is auto
-
matic, after 15 minutes, or by cutting power.
Programming using the REMOTE control
Act on the programming of the REMOTE con
-
trol to select a minimum time between two ig
-
nitions when the boiler functions in normal on/
off heating mode.
•
Press button for more than 3 seconds to
enter in
mode (Fig. 8.26).
Fig. 8.26
0
2
1
8
1
21
1 5
6
3
9
•
Press buttons
and
at the same
time to enter transparent programming (Fig.
8.27).
Fig. 8.27
•
Press buttons
or
to display the
"
PM10
" program for selecting the ignition
frequency (Fig. 8.28).
Fig. 8.28
In Fig. 8.28 a SET programmed at
90
is dis-
played corresponding to a re-ignition time of
about 3 minutes.
The adjustment field is from 0 to 8 and half
minutes.
Each step increased or decreased corre
-
sponds to 2 seconds.
•
To modify the programmed SET, act on but
-
tons
or
and wait for the number
programmed to flash (Fig. 8.29).