- 27 -
INST
ALLA
TION
TECHNICAL INFORMATION
Gas rate maximum
Natural G20
m
3
/h
1,59
Propane G31
kg/h
1,12
Gas rate minimum
Natural G20
m
3
/h
0,62
Propane G31
kg/h
0,46
Gas restrictors references
Ø mm
/100
Natural G20
620
Propane G31
450
Air/gas mixer restrictors
Natural G20
Fuchsia
Fucsia
Propane G31
Fuchsia
Fucsia
Electrical data
Voltage
V~
230
Frequency
Hz
50
Power consumption
W
125
Protection degree
IPX5D
External fuse rating
A
3
Internal fuse rating
A
N° 2 - 2 AF
Flue design
Boiler type
C13 C33 C53 C63
ø Coaxial
mm
60/100
ø Twin split pipes
mm
80/80
ø Roof
mm
80/125
Nominal heat fl ow rate
(A) (E)
kW
15
Exhaust temperature
(E)
°C
62
Mass fl ow rate
(E)
kg/s
0,0064
Flue gas fi gures
Nominal heat input
(A) (E)
kW
15,0
CO
2
content with gas G20
%
8,9 - 9,8
O
2
content with gas G20
%
3,9
CO content with gas G20
ppm
82
Exhaust temperature
(E)
°C
62
NOx class
5
Weighted NOx
mg/
kWh
34
ppm
19
(E)
Values refer tests with a 1 m fl ue working at the
nominal heat input
CO
2
contents
Nominal heat input
(A) (E)
kW 15,0
CO
2
content with gas G20 (range
min - max)
%
8,9 - 9,8
CO
2
content with gas G31 (range
min - max)
%
9,9 - 10,8
Minimum heat input
(A) (E)
kW 5,9
CO
2
content with gas G20 (range
min - max)
%
8,2 - 9,0
CO
2
content with gas G31 (range
min - max)
%
9,2 - 10,2
Other specifi cations
Height
mm
560
Width
mm
400
Depth
mm
290
Weight (dry)
kg
27
Water volume in the boiler (up to
1 bar)
l (kg)
Summary of Contents for Activ A 120V