- 31 -
INST
ALLA
TION
TECHNICAL INFORMATION
Gas rate maximum
Natural G20
m
3
/h
2,65
Propane G31
kg/h
1,94
Gas rate minimum
Natural G20
m
3
/h
0,68
Propane G31
kg/h
0,50
Gas restrictors references
Ø mm
/100
Natural G20
640
Propane G31
460
Air/gas mixer restrictors
Natural G20
Rosso
Propane G31
Rosso
Electrical data
Voltage
V~
230
Frequency
Hz
50
Power consumption
W
150
Protection degree
IPX5D
External fuse rating
A
3
Internal fuse rating
A
N° 2 - 2 AF
Flue design
Boiler type
C13 C33 C53 C63
ø Coaxial
mm
60/100
ø Twin split pipes
mm
80/80
ø Roof
mm
80/125
Nominal heat fl ow rate
(A) (E)
kW
25
Exhaust temperature
(E)
°C
75
Mass fl ow rate
(E)
kg/s
0,0111
Flue gas fi gures
Nominal heat input
(A) (E)
kW
25,0
CO
2
content with gas G20
%
8,9 - 9,8
O
2
content with gas G20
%
3,8
CO content with gas G20
ppm
160
Exhaust temperature
(E)
°C
75
NOx class
5
Weighted NOx
mg/
kWh
44
ppm
25
(E)
Values refer tests with a 1 m fl ue working at the
nominal heat input
CO
2
contents
Nominal heat input
(A) (E)
kW 25,0
CO
2
content with gas G20 (range
min - max)
%
8,9 - 9,8
CO
2
content with gas G31 (range
min - max)
%
9,9 - 10,8
Minimum heat input
(A) (E)
kW 6,4
CO
2
content with gas G20 (range
min - max)
%
8,2 - 9,2
CO
2
content with gas G31 (range
min - max)
%
9,2 - 10,2
Other specifi cations
Height
mm
560
Width
mm
400
Depth
mm
290
Weight (dry)
kg
31
Water volume in the boiler (up to
1 bar)
l (kg)
Summary of Contents for Activ A 120V
Page 20: ...20 USE USEFUL ADVICE Fig 3 7 14...
Page 81: ...81 NOTES...
Page 82: ...82 NOTES...
Page 83: ......