To modify the programmed SET, act on
buttons
or
and wait for the pro
-
grammed number to flash (Fig. 7.34). Each
step increased or decreased corresponds
to 1 second.
Fig. 7.34
•
To exit programming, press button
.
7.12 Selecting the reignition fre-
quency
When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set at three minutes (re-igni
-
tion frequency).
This time can be changed by a minimum of
zero to a maximum of eight and a half min
-
utes by acting on programming both from the
panel controls and the remote control.
•
Enter the "programming mode" by pressing
keys 11
-
12
-
13 (Fig. 7.35) for 10 seconds
at the same time until the letters
Pr
that al-
ternate with code
01
are displayed on the
LCD display, indicating that "parameter 01"
(Fig. 7.36) has been activated.
Fig. 7.35
11
12
13
Fig. 7.36
•
Scroll the various parameters using keys 12
or
13
until the letters
Pr
that alternate with
code
10
are displayed on the LCD display,
indicating that "parameter 10" (Fig. 7.37)
has been activated.