- 16 -
USE
USEFUL TIPS
The user is responsible for periodically
checking the pressure of the heating sys-
tem.
If water needs to be added too often, have
the technical support centre check if there
are any leaks in the heating system or the
boiler itself.
Water leaks from the safety valve
Check if the filling cock is closed tightly (see
"Filling the heating circuit" on page 14).
Check on the pressure gauge that the heat-
ing circuit pressure is not close to 3 bar.
Should this be the case, drain a part of the
water from the system through the air relief
valves in the radiators in order to reduce the
pressure to a normal value.
In the case of malfunctions oth
-
er than those described above,
shut down the boiler as de
-
scribed in section "Shutdown"
on page 13 and call a techni
-
cian from the authorised service
centre.
3.7 Displays in INFO mode
INFO mode is used to view boiler status in
-
formation. In the case of a boiler malfunc-
tion, provide this information to the service
centre so that they can work out its causes.
To access INFO mode, press 19 (Figure
3.7) and hold for 5 seconds until the code
n02
shows on the display (Figure 3.8).
Figure 3.7
13
14
15
16
17
18
19
Figure 3.8
bar
RESET
To scroll through the values, press 13 (in
-
crease) and 14 (decrease). Press 18 and
hold for 5 seconds to exit INFO mode (Fig
-
ure 3.7).
The table summarises the possible values
visible in INFO mode.
Table of
contents
Value shown
n02
DHW output temp.
n03
NTC return temperature (not
present)
n04
Flue gas temperature (not
present)
n05
Outdoor temperature
n08
Maximum set fan speed
(RPM/100)
n09
(not used)
n11
Flow rate