FAult Finding
4 .1 display diagnostic
The display indications provide help in the diagnosis of fault find
-
ing.
The control panel display gives other information for the user.
The following table gives fault code, error and the reson for the
fault.
E01 + RESET
Lack of burner ignition on safety lockout
E02 + RESET
Safety thermostat intervention lockout
E03 + RESET
General lockout
E04 +
Little pressure in the system or pressure
transducer disconnected
E05 +
Faulty fan control system
E06 +
Faulty c.h. temp. probe NTC1 or NTC2
E07 +
Faulty d.h.w. temp. probe NTC
E08 +
Faulty external temp. probe NTC (with K
set)
E09 +
Faulty flue temp. probe NTC (if present)
E10 + RESET
Flue probe intervention lockout (if present)
Flame detection error (An fla error
flashing number)
E12 +
Failure return NTC probe
E13 +
∆T delivery-return > 40K (if foreseen)
E14 + RESET
Faulty pump or primary temperature above
105°C
E14 +
Absence of flow from temperature gradient
(>2K/s)
E19 +
Faulty d.h.w. temp. probe inlet (if present)
E20 + RESET
Lockout EVG
E21 + RESET
Lockout EVG
E22 + RESET
Lockout EVG
E23 + RESET
Lockout EVG
E24 + RESET
Abnormal combustion ignition lock
E25 + RESET
Abnormal combustion operation lock
E69 +
Wiring error lockout
E99 +
Boiler not configured
L01
Primary circuit temp. limit during D.h.w. op-
eration