- 22 -
USE
INSTRUCTIONS FOR USE
built in 3 star comfort function that the first
d.h.w. draw off point is at a sufficient distance
to avoid excessively hot water being delivered
to the draw off point.
Setting the 3 star preheating function time
brackets
For preheating, the scheduling will be the
same for all days.
Enter ”programming mode” by holding down
keys 11 and 19 for 5 seconds (Fig. 2.29) until
the LCD display indicates the symbols shown
in Fig. 2.28.
Fig. 2.28
Fig. 2.29
11
12
13
14 15
16
17
18
19
Press key 11 or 12 to select the 4 programmes
(P1÷P4) with the related on and off times (P1
on - P1 off, …, P4 on - P4 off), with minimum
intervals of 15 minutes (Fig. 2.30).
Fig. 2.30
Press key 14 to access the time modification,
and the digits to be programmed will begin to
flash.
To modify the on and off time, press key 17
or 18.
To confirm the on/off point and move on to the
next point, press key 14 in Fig. 2.29.
If all 4 programmes (P1÷P4) are not used,
the unused programmes must be set to 0 as
shown in Fig. 2.31.
Fig. 2.31
Press key 19 briefly to save the values entered
and the display will indicate
OK
to confirm.
Summary of Contents for Inovia 25C