- 11 -
USE
APPLIANCE DESCRIPTION
LCD
FUNCTION
E08 +
A
External NTC probe
failure.
E10 +
A
Lockout due to tripping
of the flue gas probe
and thermal fuse.
E11 +
b
Parasite flame.
E12 +
A
Return NTC probe fail
-
ure.
E13 +
A
Delta T M-R > 40K.
E14 +
b
Pump fault or primary
temperature
above
105°C.
E14 +
A
Temperature
gradi
-
ent circulation failure
(>2K/s).
E18 +
b
No ∆T heating at start-
up.
E19 +
A
Auxiliary Input Probe
Anomaly.
E20 +
b
EVG lockout (valve pi
-
loting hardware failure).
E21 +
b
EVG lockout (valve
control Relay Failure).
E22 +
b
EVG lockout (flame af
-
ter closing valve Ref.
EVG).
E23 +
A
Gas valve modulator
disconnected.
LCD
FUNCTION
E24 +
A
Anomaly due to prob
-
able chimney obstruc
-
tion
E25 +
b
Flame loss for more
than 6 consecutive
times.
E26 +
A
Maximum
deviation
fault between the 2
heating NTC probes.
E40 +
A
Incorrect mains fre
-
quency detected
E42 +
A
Buttons fault.
E44 +
b
Fault of cumulative gas
valve timeout without
flame.
E50 +
A
OT
communication
fault.
E62 +
A
Calibration request.
E65 +
A
System fails to control
combustion and exits
modulator control pa
-
rameters
E68 +
A
Probably low gas pres
-
sure
E77 +
A
System out modulator
control parameters
E78 +
A
Possible low gas pres
-
sure