Technical information
21
Gas pressures at the burner
Gas
Natural
G20
Butane
G30
Propane
G31
Max.
Pa
mbar
1550
15,5
2750
27,5
3530
35,3
Min.
Pa
mbar
350
3,5
580
5,8
780
7,8
Ignition Pa
mbar
1090
10,9
1930
19,3
2470
24,7
1 mbar approximately equals 10 mm H
2
O
Gas rate
Gas
Natural
G20
m
3
/h
Butane
G30
kg/h
Propane
G31
kg/h
Max.
3,54
2,60
2,56
Min.
1,60
1,18
1,17
Injectors
mm/100ø
Natural G20
120
Butane G30
78
Propane G31
78
Electrical Data
Voltage
V~
230
Frequency
Hz
50
Power consumption
W
170
Protection degree
IPX4D
External fuse rating
A
3
Internal fuse rating
A
F1---F2 3,15 AF
Flue design
Type C12 C32 C42 C52 C82
Flue pipe diameter
Coaxial
mm
60/100
Twin split pipes
mm
80
Roof
mm
80/125
Nominal heat flow rate
(A)(D)
kW
33,0
Exhaust temperature
(D)
˚
C
64
Mass flow rate
(D)
g/s
18,0
Flue gas figures
Nominal heat input
(A)(D)
kW
33,0
CO
2
content
%
7,7
O
2
content
%
7,3
CO content
ppm
82
Exhaust temperature
(D)
˚
C
64
NO
x
class
2
Weighted NO
x
ppm
103
Other specifications
Height
mm
803
Width
mm
400
Depth
mm
350
Weight (dry)
kg
44,5
Water volume in the boiler
(up to 1 bar)
l (kg)
4,1
(D)
Values refer to tests with a 1 m chimney working at the nominal heat input
IN
S
TA
LLA
TI
O
N