Technical information
19
Gas pressures at the burner
Gas
Natural
G20
Butane
G30
Propane
G31
Max.
Pa
mbar
1130
11,3
2810
28,1
3600
36,0
Min.
Pa
mbar
240
2,4
580
5,8
780
7,8
Ignition Pa
mbar
850
8,5
2110
21,1
2700
27,0
1 mbar approximately equals 10 mm H
2
O
Gas rate
Gas
Natural
G20
m
3
/h
Butane
G30
kg/h
Propane
G31
kg/h
Max.
3,07
2,29
2,25
Min.
1,38
1,03
1,01
Injectors
mm/100ø
Natural G20
130
Butane G30
77
Propane G31
77
Electrical Data
Voltage
V~
230
Frequency
Hz
50
Power consumption
W
150
Protection degree
IPX4D
External fuse rating
A
3
Internal fuse rating
A
F1---F2 3,15 AF
Flue design
Type C12 C32 C42 C52 C82
Flue pipe diameter
Coaxial
mm
60/100
Twin split pipes
mm
80
Roof
mm
80/125
Nominal heat flow rate
(A)(D)
kW
29,0
Exhaust temperature
(D)
˚
C
69
Mass flow rate
(D)
g/s
17,8
Flue gas figures
Nominal heat input
(A)(D)
kW
29,0
CO
2
content
%
6,8
O
2
content
%
8,8
CO content
ppm
52
Exhaust temperature
(D)
˚
C
69
NO
x
class
2
Weighted NO
x
ppm
92
Other specifications
Height
mm
803
Width
mm
400
Depth
mm
350
Weight (dry)
kg
44,5
Water volume in the boiler
(up to 1 bar)
l (kg)
4,1
(D)
Values refer to tests with a 1 m chimney working at the nominal heat input
IN
S
TA
LLA
TI
O
N