- 25 -
INST
ALLA
TION
TECHNICAL SPECIFICATIONS
Heating/d.h.w. maximum gas flow rate
Methane G20
m
3
/h
3,59
Propane G31
kg/h
2,63
Minimum gas flow rate in heating mode
Methane G20
m
3
/h
1,64
Propane G31
kg/h
1,20
Minimum gas flow rate in d.h.w. mode
Methane G20
m
3
/h
1,64
Propane G31
kg/h
1,20
Max. gas pressure at the burner in heating mode
Methane G20
Pa
1200
mbar
12
Propane G31
Pa
3310
mbar
33,1
Min. gas pressure at the burner in heating mode
Methane G20
Pa
220
mbar
2,2
Propane G31
Pa
750
mbar
7,5
Ignition pressure
Methane G20
Pa
720
mbar
7,2
Propane G31
Pa
2320
mbar
23,2
Nozzles
N°
Ø mm
/100
Methane G20
15
130
Propane G31
15
78
Chimney design #
Max. flue gas temperature
°C
125
Min. flue gas temperature
°C
114
Max. flue gas mass flow rate
kg/s
0,0196
Min. flue gas mass flow rate
kg/s
0,0205
Max. air mass flow rate
kg/s
0,0190
Min. air mass flow rate
kg/s
0,0205
# Values refer to tests with 80 mm 1 + 1 twin pipe
discharge and Methane gas G20
Flue gas discharges
Boiler type
B22 C12 C32 C42 C52 C62 C82
Coaxial air/flue gas duct Ø
mm
60/100
Twin pipe air/flue gas duct Ø
mm
80/80
Coaxial air/flue gas duct to roof Ø
mm
80/125
Other characteristics
Height
mm
703
Width
mm
400
Depth
mm
325
Weight
kg
34
G20 Hi. 34.02 MJ/m3 (15°C, 1013.25 mbar)
G31 Hi. 46.34 MJ/kg (15°C, 1013.25 mbar)
1 mbar corresponds to approx. 10 mm H20
(2304)