15. Commissioning Cont.
sequence
P01
alternates with
-- -- --
).
Figure 15.23
•
Press the reset button 6, in Figure 15.21,
to scroll the various parameters until
reaching the valid parameter
P15
for
appear on the LCD display (the sequence
P15
alternates with
00
).
Figure 15.24
•
Set the value by turning knob 8 in Figure
15.21 from a minimum of
30
(the sequence
P15
alternates with
30
)
Figure 15.25
to a maximum of
255
based on the
Figure
15.20.
Figure 15.26
0
0,5
1
1,5
2
3
6
4
00
30
90
140
182
200
218
255
LCD Value
Coeff. K
Setting No.
•
Once the desired value is set, the
that it was stored occurs
automatically, after 5 seconds, with
OK
appearing on the LCD display.
Figure 15.27
•
To exit programming, position the function
selector/heating temperature adjustment
knob 7 as shown in Figure 15.28.
Figure 15.28
8
7
6
Knob 7 must be positioned as shown in
Figure 15.29 to respect the trend of the
delivery temperature with respect to the set
RIVA ADVANCE COMBI MANUAL
5
0