RIVA ADVANCE COMBI MANUAL
52
15. Commissioning Cont.
15.8 Labels placement:
Figure 15.33
1
4
2
3
5
Warning: The installation is not complete unless labels supplied are placed on the
boiler as shown in Figure 15.33.
All the labels supplied with the boiler are numbered for reference.
According to Figure 15.33 place all the labels on the boiler. Use label numbered as 1 (already
installed in the front panel) to begin the placement in the correct way.
15.9 Checking the flue system and combustion:
• The flue system should be visually
checked for soundness. Check all clamps,
gaskets and fixings are secure and tight.
• Ensure that the flue terminal is sited
correctly in accordance with the flue fitting
instructions.
To check the exhaust gas:
• Remove the plugs indicated (Fig. 15.34).
• Insert the analyzer probe in the exhaust
gas sampling point or in the air intake
sampling point.
• Reference tables are given in the Sections
2 on page 9 of this manual for proper CO
2
levels.